Summary
PRRES20213720
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINSISHED AND UNFINISHED BASEMENT - COVERED PATIO AFFINITY CONSTRUCTION DOING BASEMENT FINISH
07/20/2021
08/05/2021
01/16/2022
04/14/2023
Locations
Contacts
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
DAVE@DAVERICHARDSHOMES.COM  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
AFFINITY CONSTRUCTION & CONTRACTING LLC, Address:32003 E FRISTOE RD, Phone:(816) 785-4090  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,617.14 $1,617.14 Paid 08/05/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/05/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/05/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 08/05/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/05/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/05/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/24/2022
9110078-Additional Permit Fee $50.00 $50.00 Paid 12/14/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/11/2021 08/11/2021
Informational
08/11/2021
FOOTING APPROVED BY ENGINEER
Underslab Plumbing Inspection - Residential Passed 9/17/2021 9/17/2021 09/17/2021
Sewer Service Inspection - R Passed 9/17/2021 9/17/2021 09/17/2021
Water Service Inspection - R Passed 9/22/2021 09/22/2021
Driveway Inspection Partial 4/6/2022 4/6/2022 04/06/2022
Misc
Informational
04/06/2022
4-6-22 AN forms are in place and aggregate is present and compacted.
Driveway Inspection Passed 4/8/2022 4/8/2022 04/08/2022
Misc
Informational
04/06/2022
4-6-22 AN forms are in place and aggregate is present and compacted.
Misc
Informational
04/08/2022
4-8-22 AN driveway looks good and has expansion joints at curb and right of way. Meets Ada spec
Gas Service Inspection - Residential Failed 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/26/2022
-Pressure currently is less than ten psi
Electrical Service Inspection Passed 4/26/2022 4/26/2022 04/26/2022
All Rough Inspection - Residential Failed 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/26/2022
-Install window trims and flashings -Provide min 2”x2” washers at garage PFH walls -Fix broken stem wall at garage PFH wall corner -Solid block joist ends above garage -Fb all wall plate penetrations ; Fb floor penetration at traps -Support joists to I beam with hangers above main floor bathroom -Support roof above rear 1st fl bedroom closet -W8X48 I beam is not supported at correct location due to door relocation. Have engineer address support of this I beam -Protect wiring at bottom wall plate near range -Install windows -Install stud shoe at over bored stud at kitchen sink window -Strap all exterior wall and interior bearing wall top plates where bored more than 50% -Protect 3/4” csst gas line per manufacturer: Cannot secure csst gas line within stud space.; Csst gas line must be able to be displaced 3”; protect min 5” beyond wall plates -Install hanger support for 3x joists at W8X48 I beam connection -Shim excessive gap at jack studs for slide door header -Fb plumbing space at stair from soffit and joist space; Fb floor penetrations within this space -Provide (3)2x6 stud support for W8X48 beam per plan -Solid block joist ends above front dining exterior wall -Provide 19” CSPF walls at front dining room per plan -Engineer address for tall 2x4 wall at entry and stair. Code requires continuous 2x6 studs -Protect plumbing vent at middle and master bedroom wall -Provide (3)2x4 support for lvl roof beam at master closet walls -Fb all spaces at both master closets and laundry from roof -Install hanger for double joist connection to lvl roof beam above master closet -Dryer duct shall not be distorted from its round shape. You need 2x6 wall, especially with all the things in the way -Protect plumbing in laundry and bathroom per code. Provide BOCA plates at top plate; install stud shoe where bored more than 60% -Studs at front bedroom gable wall not continuous -Front bedroom wall top plates not lapped with entry wall -Nail corner studs per code (16d @12” or equivalent nailing) -Have engineer address double and triple joists not directly under 2nd fl bedroom walls, especially the triple joists -Provide vertical fire blockings at stair along foundation wall per code -Provide vent available for future basement bathroom **DO NOT INSULATE
All Rough Inspection - Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
04/26/2022
-W8X48 I beam is not supported at correct location due to door relocation. Have engineer address support of this I beam -Protect 3/4” csst gas line per manufacturer: Cannot secure csst gas line within stud space.; Csst gas line must be able to be displaced 3”; protect min 5” beyond wall plates -Solid block joist ends above front dining exterior wall -Engineer address for tall 2x4 wall at entry and stair. Code requires continuous 2x6 studs -Protect plumbing vent at middle and master bedroom wall -Have engineer address double and triple joists not directly under 2nd fl bedroom walls, especially the triple joists -Provide vent available for future basement bathroom **ok to INSULATE
All Rough Inspection - Residential Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/06/2022
-Protect 3/4” csst gas line per manufacturer: Cannot secure csst gas line within stud space. Csst gas line must be able to be displaced min 3”; protect min 5” beyond wall plates **Please read the manufacturer installation manual available from its website **OK TO INSULATE
Gas Service Inspection - Residential Failed 6/21/2022 06/21/2022
Misc
Corrective Action Required
04/26/2022
-Pressure currently is less than ten psi **Provide a proper working pressure gauge
All Rough Inspection - Residential Passed 6/22/2022 6/22/2022 06/22/2022
Misc
Resolved
06/22/2022
-Protect 3/4” csst gas line per manufacturer: Cannot secure csst gas line within stud space. Csst gas line must be able to be displaced min 3”; protect min 5” beyond wall plates **Please read the manufacturer installation manual available from its website **OK TO INSULATE
Gas Service Inspection - Residential Passed 6/22/2022 6/22/2022 06/22/2022
Misc
Resolved
06/22/2022
-Pressure currently is less than ten psi **Provide a proper working pressure gauge
Sidewalk Inspection Partial 8/18/2022 8/18/2022 08/18/2022
Misc
Informational
08/18/2022
8-18-22 AN forms are in place and aggregate is present and compacted
Sidewalk Inspection Failed 8/19/2022 8/19/2022 08/19/2022
Misc
Informational
08/18/2022
8-18-22 AN forms are in place and aggregate is present and compacted
Misc
Corrective Action Required
08/19/2022
8-19-22 AN no white cure on sidewalk
Piers/Caissons Inspection - Residential Passed 8/23/2022 08/23/2022
Informational
08/23/2022
PIERS APPROVED BY ENGINEER
Occupancy Inspection - Codes Residential Failed 8/23/2022 8/23/2022 08/23/2022
Misc
Corrective Action Required
08/23/2022
**CLEAN UP THE STREET. INSTALL EROSION CONTROL ALONG THE STREET -Sidewalk not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, seal exterior lights, etc -Water meter buried -Provide guardrail at open side of loft -Pendants not allowed in master closets. Luminaries must be enclosed lamp type -Pendant not allowed within bath tub zone -Install water hammering arrestor at clothes washer water outlet -Slope furnace condensate pipe toward drain (min 1/4” per ft) -Fb floor penetration at master tub trap -Provide receptacle for cabinet wall spaces adjacent to fireplace as required per code. Cabinets with countertop is considered as a wall space where receptacle spacing is required -Complete venting kitchen hood -Provide garage stair handrail profile per code -Fb underneath boxed out wall in garage -Handrail of lower stair flight to basement must be 34”-38” above tread-tread plane -Install airtight plug at sewer clean out -Install backflow preventer at hose bibb -Remove foundation wall tie at basement window -Anchor basement columns
Sidewalk Inspection Partial 8/23/2022 8/23/2022 08/23/2022
Misc
Informational
08/19/2022
8-18-22 AN forms are in place and aggregate is present and compacted
Misc
Corrective Action Required
08/19/2022
8-19-22 AN no white cure on sidewalk 8-23-22 AN. White cure has been sprayed on but does not appear that the sidewalk goes all the way to the property line
Occupancy Inspection - Codes Residential Ready for Temp CO 8/24/2022 8/24/2022 08/24/2022
Misc
Corrective Action Required
08/23/2022
-Sidewalk not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension
Occupancy Inspection - Codes Residential Temporary C of O 8/24/2022 08/24/2022
Misc
Corrective Action Required
08/24/2022
-Sidewalk not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension
Sidewalk Inspection Passed 8/23/2022 8/23/2022 08/25/2022
Misc
Informational
08/23/2022
8-18-22 AN forms are in place and aggregate is present and compacted
Misc
Corrective Action Required
08/23/2022
8-19-22 AN no white cure on sidewalk 8-23-22 AN. White cure has been sprayed on but does not appear that the sidewalk goes all the way to the property line 8-25-22 AN. Verified the sidewalk to the property line
All Rough Inspection - Residential Failed 1/13/2023 1/13/2023 01/13/2023
Misc
Corrective Action Required
01/13/2023
-Move the smoke alarm min 4” away from wall -Extend return air to ceiling level of bedroom -Cannot supply the receptacle inside mechanical space from bath receptacle circuit
Plot Plan Inspection Passed 3/1/2023 03/01/2023
All Rough Inspection - Residential Passed 04/03/2023
Misc
Resolved
04/03/2023
-Move the smoke alarm min 4” away from wall -Extend return air to ceiling level of bedroom -Cannot supply the receptacle inside mechanical space from bath receptacle circuit
Miscellaneous Inspection Passed 4/3/2023 4/3/2023 04/03/2023
Occupancy Inspection - Codes Residential Full C of O 3/9/2023 4/3/2023 04/14/2023
Misc
Resolved
03/01/2023
-Final grade, sod, downspout and sump pump extension
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home