Summary
PRRES20213596
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
07/12/2021
08/04/2021
11/08/2022
Locations
Contacts
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210, Phone:(816) 524-5245  
Rick holbrook , Address:528 NW. AA Highway  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
RICK@PFEIFERHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/04/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/04/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/04/2021
9110078-Valuation Fee New Single Family $1,286.61 $1,286.61 Paid 08/04/2021
$1,291.61
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/04/2021
8331507-Sewer Connection Fee $540.00 $540.00 Paid 08/04/2021
9110080-Not Ready Inspection Fee $0.00 $0.00 Paid 11/08/2022
$75.00
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/08/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/08/2022
$75.00
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/9/2021 (1:30) 8/9/2021 08/09/2021
Misc
Informational
08/09/2021
UFER LOCATED NORTH FOUNDATION WALL NEAR REAR GARAGE FOUNDATION WALL
Sewer Service Inspection - R Passed 9/14/2021 09/14/2021
Water Service Inspection - R Partial 9/14/2021 09/14/2021
Misc
Informational
09/14/2021
- PARTIAL 6' FROM FOUNDATION WALL NO METER PIT SET
Underslab Plumbing Inspection - Residential Failed 9/15/2021 9/15/2021 09/15/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
09/15/2021
- PLACE INTERIOR DRAIN TILE AT PERIMETER OF BASEMENT - CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Water Service Inspection - R Passed 9/15/2021 09/15/2021
Misc
Informational
09/14/2021
- PARTIAL 6' FROM FOUNDATION WALL NO METER PIT SET - - COMPLETE APPROVED -
Erosion Control Inspection Residential Failed 9/17/2021 09/17/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/17/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Underslab Plumbing Inspection - Residential Passed 9/17/2021 09/17/2021
R506.2.5 Interior Underslab Drains
Resolved
09/17/2021
Piers/Caissons Inspection - Residential Failed 11/2/2021 (9:15) 11/2/2021 11/02/2021
Miscellaneous Correction
Corrective Action Required
11/02/2021
(2) 24 X 36 COVERED DECK PIERS OK TO POUR PLAN SHOWS (3) PIERS DETAIL K AT CORNER OF THE HOUSE FULL OF WATER
Piers/Caissons Inspection - Residential Passed 12/21/2021 (8:00) 12/21/2021 12/21/2021
Miscellaneous Correction
Resolved
12/21/2021
(2) 24 X 36 COVERED DECK PIERS OK TO POUR PLAN SHOWS (3) PIERS DETAIL K AT CORNER OF THE HOUSE FULL OF WATER
All Rough Inspection - Residential Failed 2/17/2022 2/17/2022 02/17/2022
Misc
Corrective Action Required
02/17/2022
-Unable to verify PFH nailing pattern or hold downs -Solid block and nail horizontal sheathing breaks at PFH per detail -Provide 2 rows 16d sinkers 3” oc at top plate to header at PFH per detail -Address rafters landing on multiple plates, smart trim etc and not connected to ceiling joists at garage -Nail all corner studs and intersecting wall studs per code -Address top plates not lapped Min 24” and exterior walls not connected at top plate at garage/entry at beam -Provide anchor bolt within 3.5” of end of plate by entry -Seal bottom plate penetration at garage/entry -Fireblock top of B vent chase with approved means -Provide lateral restraint at ceiling joists above beams and bearing walls -Bocca plate at refrigerator line -Address porch beam/ hip bearing on ceiling joists above 2 car bay -Support hip rafters above kitchen -Provide rafter ties throughout where rafters not connected to ceiling joists at top plate -Provide midpoint strap at all dwv 2”and smaller -Connect bath exhaust fans -Cripple walls less than 14” are required to be continuously sheathed on one side at kitchen/great room -Fireblock top hvac chase with approved means at laundry -Seal through floor penetrations at wc -Provide bonding screw and jumper at metallic box at pantry -Provide proper slope at dwv in attic -Address strut at hip bearing on ceiling joist above covered deck -Address dining room to be 2x4 framing 12” oc -Address exterior walls not connected at top plate back dining room -Solid shim all trimmer studs cut short of headers -Address cut corner studs at dining -Fireblock fireplace and dead spaces adjacent to fireplace from attic space -Address hole in exterior sheathing at dead space in great room -Provide hanger at joist to beam in great room by stairs -Provide lateral restraint at double LVL beam in kitchen -Support hip rafters at ridge above entry -Complete plumbing at master -provide (7) stud pack at steel beam great room, stud pack for bearing shall be on garage wall per plans -solid shim all trimmer studs cut short of headers throughout -fireblock between studs and deadspace at 1st floor stair wall open to attic -add stud shoe DWV master bath water closet -provide structural straps at all exterior walls and interior load bearing walls bored 50% or more, straps min 1 1/2” wide, 16 gauge, extend 6” passed each side of opening with min (4) 10D nailed each side of strap -tighten all anchor bolts at basement -security blocking basement walkout -solid block at step flashing -Provide Bocca plates at dwv and pex in basement less than 1.25” to face of stud -Complete plumbing in basement -Fireblock all dead spaces in basement -3 studs required at exterior corners in basement -Bonding screw and jumper at all metallic boxes in basement -Ufer must remain accessible -Complete fireblocking between walls at ceiling line basement bed/bath -Fireblock stairs from garage to basement -Sister over notched studs in exterior wall of basement bedroom
Gas Service Inspection - Residential Passed 2/17/2022 2/17/2022 02/17/2022
Electrical Service Inspection Passed 2/17/2022 2/17/2022 02/17/2022
All Rough Inspection - Residential Not Ready 3/2/2022 3/2/2022 03/02/2022
Misc
Corrective Action Required
02/17/2022
3/2/22 NOT READY No engineers letter addressing issues, numerous issues incomplete ( fire blocking, straps ) -Unable to verify PFH nailing pattern or hold downs -Provide 2 rows 16d sinkers 3” oc at top plate to header at PFH per detail -Address rafters landing on multiple plates, smart trim etc and not connected to ceiling joists at garage -Nail all corner studs and intersecting wall studs per code -Address top plates not lapped Min 24” and exterior walls not connected at top plate at garage/entry at beam -Provide anchor bolt within 3.5” of end of plate by entry -Fireblock top of B vent chase with approved means -Provide lateral restraint at ceiling joists above beams and bearing walls -Address porch beam/ hip bearing on ceiling joists above 2 car bay -Support hip rafters above kitchen -Provide rafter ties throughout where rafters not connected to ceiling joists at top plate -Cripple walls less than 14” are required to be continuously sheathed on one side at kitchen/great room -Fireblock top hvac chase with approved means at laundry -Address exterior walls not connected at top plate back dining room -Solid shim all trimmer studs cut short of headers -Support hip rafters at ridge above entry -solid shim all trimmer studs cut short of headers throughout -fireblock between studs and deadspace at 1st floor stair wall open to attic -provide structural straps at all exterior walls and interior load bearing walls bored 50% or more, straps min 1 1/2” wide, 16 gauge, extend 6” passed each side of opening with min (4) 10D nailed each side of strap -tighten all anchor bolts at basement -solid block at step flashing -Provide Bocca plates at dwv and pex in basement less than 1.25” to face of stud -Complete plumbing in basement -Fireblock all dead spaces in basement -3 studs required at exterior corners in basement -Bonding screw and jumper at all metallic boxes in basement -Ufer must remain accessible -Complete fireblocking between walls at ceiling line basement bed/bath -Fireblock stairs from garage to basement -Sister over notched studs in exterior wall of basement bedroom
All Rough Inspection - Residential Passed 4/15/2022 4/15/2022 04/20/2022
Misc
Resolved
04/15/2022
Driveway Inspection Partial 8/2/2022 8/2/2022 08/02/2022
Misc
Informational
08/02/2022
Driveway was framed up with aggregate in and compacted. 8/2/22 ES
Driveway Inspection Passed 8/8/2022 8/8/2022 08/15/2022
Misc
Informational
08/02/2022
Driveway was framed up with aggregate in and compacted. 8/2/22 ES Driveway meets LS and Ada spec. 8/15/22 ES
Erosion Control Inspection Residential Failed 10/11/2022 10/11/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/17/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/11/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 10/28/2022 10/28/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/11/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/11/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM5 ESC INSP DENIED
Corrective Action Required
10/28/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Failed 10/28/2022 10/28/2022 10/28/2022
Miscellaneous Correction
Corrective Action Required
04/15/2022
PROVIDE UFER ACCESS ABOVE SERVICE PANEL TO LEFT IN BEDROOM CLOSET :CHECK ON FINAL:
Miscellaneous Correction
Corrective Action Required
10/28/2022
NOT READY NO INSPECTION THIS LIST IS INCOMPLETE SUBJECT TO CHANGE WHEN BELOW ITEMS ARE CORRECTED NO EROSION CONTROL NO ADDRESS GARAGE DOOR SHALL BE SELF CLOSING NO DEADBOLT GARAGE DOOR CAP DRAIN PIPE LAUNDRY TUB GARAGE SIDEWALK INSPECTION PENDING OBTAIN IRRIGATION PERMIT SUBMIT BACKFLOW CERTIFICATION Sec. 7-1402. - Adopted codes. The provisions of this article are in addition to the Building Code, Fire Code, Electrical Code and Residential Code as adopted and amended by the City of Lee's Summit. (Ord. No. 8584, § 1, 3-19-2019) Sec. 7-1403. - Premises identification. Approved numbers or addresses shall be provided for all new dwelling unit structures in such a position as to be plainly visible and legible from the street or road fronting the property. Each dwelling unit within a multiple dwelling unit structure shall be identified at the main entry with premises identification unique to each dwelling unit. Residential dwelling units and structures housing multiple dwelling units accessed by private drive(s) or parking lot(s) shall also provide approved numbers or addresses in such a position as to be plainly visible and legible from such drive(s) or parking lot(s). Approved numbers or address characters shall be a minimum height of four (4) inches (76 mm) and minimum stroke of one-half-inch (12.7 mm). Approved numbers or address characters shall be of a contrasting color to the background itself. (Ord. No. 8584, § 1, 3-19-2019) Sec. 7-1404. - Premises identification illumination. Required premises identification shall be capable of being illuminated during the hours of darkness with a power source connected to the dwelling unit electrical system or by other means approved by the Building Official. (Ord. No. 8584, § 1, 3-19-2019)
Occupancy Inspection - Codes Residential Not Ready 11/4/2022 11/04/2022
Miscellaneous Correction
Resolved
11/04/2022
PROVIDE UFER ACCESS ABOVE SERVICE PANEL TO LEFT IN BEDROOM CLOSET :CHECK ON FINAL:
Miscellaneous Correction
Resolved
11/04/2022
NOT READY NO INSPECTION THIS LIST IS INCOMPLETE SUBJECT TO CHANGE WHEN BELOW ITEMS ARE CORRECTED NO EROSION CONTROL NO ADDRESS GARAGE DOOR SHALL BE SELF CLOSING NO DEADBOLT GARAGE DOOR CAP DRAIN PIPE LAUNDRY TUB GARAGE SIDEWALK INSPECTION PENDING OBTAIN IRRIGATION PERMIT SUBMIT BACKFLOW CERTIFICATION Sec. 7-1402. - Adopted codes. The provisions of this article are in addition to the Building Code, Fire Code, Electrical Code and Residential Code as adopted and amended by the City of Lee's Summit. (Ord. No. 8584, § 1, 3-19-2019) Sec. 7-1403. - Premises identification. Approved numbers or addresses shall be provided for all new dwelling unit structures in such a position as to be plainly visible and legible from the street or road fronting the property. Each dwelling unit within a multiple dwelling unit structure shall be identified at the main entry with premises identification unique to each dwelling unit. Residential dwelling units and structures housing multiple dwelling units accessed by private drive(s) or parking lot(s) shall also provide approved numbers or addresses in such a position as to be plainly visible and legible from such drive(s) or parking lot(s). Approved numbers or address characters shall be a minimum height of four (4) inches (76 mm) and minimum stroke of one-half-inch (12.7 mm). Approved numbers or address characters shall be of a contrasting color to the background itself. (Ord. No. 8584, § 1, 3-19-2019) Sec. 7-1404. - Premises identification illumination. Required premises identification shall be capable of being illuminated during the hours of darkness with a power source connected to the dwelling unit electrical system or by other means approved by the Building Official. (Ord. No. 8584, § 1, 3-19-2019)
Misc
Corrective Action Required
11/04/2022
-pay all fees -Garage stairs greater than 3/8 difference in rise -spark rings at kitchen/ prep kitchen / basement wet bar counter top outlets where required by code -security screws at exterior doors 2 per hinge and strike plate -spark ring at outlet above fire place -missing hardware at front door -remove chandelier in master bath within 8’ of tub edge -safety glazing for basement Rear windows closer than 18” to floor OBTAIN IRRIGATION PERMIT SUBMIT BACKFLOW CERTIFICATION
Erosion Control Inspection Residential Passed 11/8/2022 11/08/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/28/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/28/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM5 ESC INSP DENIED
Corrective Action Required
10/28/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Plot Plan Inspection Passed 11/8/2022 11/08/2022
Occupancy Inspection - Codes Residential Full C of O 11/8/2022 11/08/2022
Misc
Corrective Action Required
11/08/2022
-pay all fees -Garage stairs greater than 3/8 difference in rise -spark rings at kitchen/ prep kitchen / basement wet bar counter top outlets where required by code -security screws at exterior doors 2 per p ol hinge and strike plate -spark ring at outlet above fire place -missing hardware at front door -remove chandelier in master bath within 8’ of tub edge -safety glazing for basement Rear windows closer than 18” to floor
Documents & Images
Date Uploaded File Type Document Name
07/12/2021 cypress 79 permit
07/12/2021 cypress 79 permit (2)
07/19/2021 RWR079 SPEC - Sealed Plans (June 25, 2021)
08/02/2021 Plot Plan Approved Plot Plan
08/02/2021 Approved Plans Approved Drawings
08/02/2021 Letter Codes Residential Plan Review
08/04/2021 Letter Codes Residential Plan Review
08/04/2021 Permit DS Building Permit
08/04/2021 Receipt Receipt for transaction: 2021-006237
08/09/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
11/02/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
02/17/2022 Letter INSPECTION SUMMARY
02/17/2022 Letter INSPECTION SUMMARY
02/17/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/17/2022 321 NW Amberssham Roughin Inspection Letter
04/15/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
10/11/2022 Letter INSPECTION SUMMARY
10/28/2022 Letter INSPECTION SUMMARY
10/28/2022 Letter INSPECTION SUMMARY
11/04/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter Codes Final Certificate of Occupancy
11/08/2022 Letter Field Certificate of Occupancy
11/08/2022 Receipt Receipt for transaction: 2022-008771
11/08/2022 Letter Codes Final Certificate of Occupancy
11/08/2022 Receipt Receipt for transaction: 2022-008808
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home