Permit Application Status

PRRES20213592


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213592
Building Permit - Residential
Certificate of Occupancy
NEW 3 OR 4 FAMILY
NEW FOUR PLEX - UNFINISHED BASEMENT - UNCOVERED PATIO BASEMENT FINISH FOR UNIT 3726 ONLY
07/12/2021
07/13/2021
10/18/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $3,342.02 $3,342.02 Paid 07/13/2021
8331507-Sewer Connection Fee $1,560.00 $1,560.00 Paid 07/13/2021
8331401-Water Tap Fee $14,620.00 $14,620.00 Paid 07/13/2021
8350015-Water Meter Fee $1,916.96 $1,916.96 Paid 07/13/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/13/2021
7232302-Residential Excise Tax Fee $4,308.48 $4,308.48 Paid 07/13/2021
8331504-EFHB Middle Big Creek, Full $1,740.96 $1,740.96 Paid 10/22/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/25/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/25/2023
9110078-Additional Permit Fee $96.00 $96.00 Paid 08/25/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/17/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/17/2023
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 11/24/2021 (8:00) 11/24/2021 11/24/2021
Misc
Corrective Action Required
11/24/2021
-ALL D pads no to depth per plans -multiple areas not to width/depth per plans
Footing Inspection - Residential Passed 11/24/2021 11/24/2021 11/24/2021
Misc
Resolved
11/24/2021
-ALL D pads no to depth per plans -multiple areas not to width/depth per plans
Sewer Service Inspection - R Partial 1/18/2022 01/18/2022
Misc
Informational
01/18/2022
3720 OK
Sewer Service Inspection - R Passed 1/19/2022 (10:00) 1/19/2022 01/19/2022
Misc
Informational
01/18/2022
3720 OK 3726 OK
Sewer Service Inspection - R Partial 1/24/2022 (1:15) 1/24/2022 01/24/2022
Misc
Informational
01/24/2022
3722 OK
Sewer Service Inspection - R Passed 1/25/2022 01/25/2022
Misc
Informational
01/24/2022
3722,3724 OK
Underslab Plumbing Inspection - Residential Passed 1/25/2022 1/25/2022 01/25/2022
Misc
Informational
01/25/2022
3720, 3722, 3724, 3726 OK
Water Service Inspection - R Passed 1/28/2022 (8:00) 1/28/2022 01/28/2022
Misc
Informational
01/28/2022
3720,3722,3724,3726 OK
Erosion Control Inspection Residential Failed 1/28/2022 1/28/2022 01/28/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/28/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 8/2/2023 08/02/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/28/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Miscellaneous Correction
Corrective Action Required
08/02/2023
Perimeter erosion control is not in place. Erosion control must be in place before further inspections will be completed 08/02/2023. KBEARD
All Rough Inspection - Residential Failed 7/31/2023 7/31/2023 08/02/2023
Miscellaneous Correction
Corrective Action Required
07/31/2023
3726 - Address header above kitchen sink. Not per plan - Insulate in garage chase - LIB in kitchen needs to be remained - Nail plate missing in master bathroom toilet - Nail plate missing at dryer top plate - Dryer vent through the roof is not complete - Need three joist hangers in the master closet - Missing plumbing nail plate in bathroom of bedroom 2 - Truss tie down screw in bedroom 2 missing - Basement a/c supply line needs a hanger - UFER is not being utilized for grounding - Gas line is not grounded - Electrical panel is not installed - Joist hanger behind furnace in not installed correctly - NOT A COMPLETE LIST. Electrical was not completed No other units were inspected
Rated Assembly Inspection Failed 8/2/2023 8/2/2023 08/02/2023
Electrical Service Inspection Failed 8/2/2023 8/2/2023 08/02/2023
Gas Service Inspection - Residential Failed 8/2/2023 08/02/2023
Miscellaneous Correction
Informational
08/02/2023
3726 and 3724 passed only. This is a partial pass
Electrical Service Inspection Failed 8/2/2023 08/02/2023
Miscellaneous Correction
Corrective Action Required
08/02/2023
3726 and 3724 both passed. This is a partial only
Rated Assembly Inspection Failed 8/2/2023 08/02/2023
Misc
Corrective Action Required
08/02/2023
3724 and 3726 both passed. This is a partial only
All Rough Inspection - Residential Failed 8/2/2023 8/2/2023 08/02/2023
Miscellaneous Correction
Corrective Action Required
07/31/2023
3726 - Address header above kitchen sink. Not per plan - Insulate in garage chase - LIB in kitchen needs to be remained - Nail plate missing in master bathroom toilet - Nail plate missing at dryer top plate - Dryer vent through the roof is not complete - Need three joist hangers in the master closet - Missing plumbing nail plate in bathroom of bedroom 2 - Truss tie down screw in bedroom 2 missing - Basement a/c supply line needs a hanger - UFER is not being utilized for grounding - Gas line is not grounded - Electrical panel is not installed - Joist hanger behind furnace in not installed correctly - NOT A COMPLETE LIST. Electrical was not completed No other units were inspected
Misc
Corrective Action Required
08/02/2023
3726 • Address header above kitchen sink. Not per plan • Insulate in garage chase • LIB in kitchen needs to be remained • Nail plate missing in master bathroom toilet • Nail plate missing at dryer top plate • Dryer vent through the roof is not complete • Need three joist hangers in the master closet • Missing plumbing nail plate in bathroom of bedroom 2 • Truss tie down screw in bedroom 2 missing • Basement a/c supply line needs a hanger • Joist hanger behind furnace in not installed correctly 3724 • LIB in entry bathroom is not completely nailed off • Address rated assembly up against truss on north wall • Dryer vent is missing a BOCA plate on both sides • Address all trusses that have been scabbed onto along the webbing and bottom cord • Upstairs bedroom west side wall needs a nail plate for electrical wire • Upstairs bedroom needs a truss screw in the bedrooms west wall • Attic access needs a clearance 30 inches of head room • Radon is not completely installed
All Rough Inspection - Residential Failed 8/3/2023 8/3/2023 08/03/2023
Miscellaneous Correction
Corrective Action Required
08/02/2023
3726 - Basement a/c supply line needs a hanger installed (line is over 10 ft) - Joist hanger behind furnace in not installed correctly, nails were installed at a angle and do not serve it intended purpose Not a complete list , all trades were not completed at the time of inspection
Misc
Corrective Action Required
08/02/2023
3726 • Basement a/c supply line needs a hanger (it is over 10 feet in length) • Joist hanger behind furnace in not installed correctly, nails were installed at an angle and does not serve its intended purpose 3724 • Address all trusses that have been scabbed onto along the webbing and bottom cord • Radon is not completely installed This is a partial list, units 3722 and 3720 will be scheduled at a later date 08/03/2023 KBEARD
Gas Service Inspection - Residential Failed 8/3/2023 8/3/2023 08/03/2023
Miscellaneous Correction
Informational
08/02/2023
3726 and 3724 passed only. This is a partial pass only
Rated Assembly Inspection Failed 8/3/2023 8/3/2023 08/03/2023
Misc
Corrective Action Required
08/02/2023
3724 and 3726 both passed. This is a partial only
All Rough Inspection - Residential Failed 8/4/2023 8/4/2023 08/04/2023
Miscellaneous Correction
Resolved
08/04/2023
3726 - Basement a/c supply line needs a hanger installed (line is over 10 ft) - Joist hanger behind furnace in not installed correctly, nails were installed at a angle and do not serve it intended purpose Not a complete list , all trades were not completed at the time of inspection
Misc
Resolved
08/04/2023
3726 • Basement a/c supply line needs a hanger (it is over 10 feet in length) • Joist hanger behind furnace in not installed correctly, nails were installed at an angle and does not serve its intended purpose 3724 • Address all trusses that have been scabbed onto along the webbing and bottom cord • Radon is not completely installed This is a partial list, units 3722 and 3720 will be scheduled at a later date 08/03/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
08/04/2023
3726 still needs a support hanger in the basement for the a/c supply vent line that is over 10 feet in length. This is the third time this has been noted on an all rough. Okay to insulate and sheet rock since basement is unfinished. This is a partial pass only. 3720 and 3722 will be inspected at a later date 08/04/2023. KBEARD time 9:45AM
Electrical Service Inspection Passed 8/8/2023 08/08/2023
Miscellaneous Correction
Corrective Action Required
08/07/2023
3726 and 3724 both passed. This is a partial only
All Rough Inspection - Residential Failed 8/8/2023 8/8/2023 08/08/2023
Miscellaneous Correction
Resolved
08/08/2023
3726 still needs a support hanger in the basement for the a/c supply vent line that is over 10 feet in length. This is the third time this has been noted on an all rough. Okay to insulate and sheet rock since basement is unfinished. This is a partial pass only. 3720 and 3722 will be inspected at a later date 08/04/2023. KBEARD time 9:45AM
Miscellaneous Correction
Corrective Action Required
08/08/2023
3722 - Gas line gauge reads 2 lbs at the start of inspection and does not have enough pressure for proper inspection - Anchor bolts in garage are not tightened down - Supply register above front porch ceiling needs seam tape applied at joint - Address broken plywood decking at rated assembly along the south wall ridge - Address repaired trusses in master bathroom and utility room - Install joist hangers in the master bedroom tray ceiling 2x4s that have a 12 foot span 3720 All passed Okay to start insulating on 3720 only
Gas Service Inspection - Residential Failed 8/8/2023 8/8/2023 08/08/2023
Miscellaneous Correction
Informational
08/03/2023
3726 and 3724 passed only. This is a partial pass only
Miscellaneous Correction
Corrective Action Required
08/08/2023
Gas gauge at 3722 read 2 lbs upon arrival and does not have enough pressure for a proper inspection 3720 passed
Rated Assembly Inspection Failed 8/8/2023 8/8/2023 08/08/2023
Misc
Corrective Action Required
08/03/2023
3724 and 3726 both passed. This is a partial only
Misc
Corrective Action Required
08/08/2023
3722 Rated assembly decking by the south wall at the ridge has a hole that needs to be addressed 3720 Passed
All Rough Inspection - Residential Not Ready 8/9/2023 8/9/2023 08/09/2023
Miscellaneous Correction
Corrective Action Required
08/08/2023
3722 - Gas line gauge reads 2 lbs at the start of inspection and does not have enough pressure for proper inspection - Anchor bolts in garage are not tightened down - Supply register above front porch ceiling needs seam tape applied at joint - Address broken plywood decking at rated assembly along the south wall ridge - Address repaired trusses in master bathroom and utility room - Install joist hangers in the master bedroom tray ceiling 2x4s that have a 12 foot span 3720 All passed Okay to start insulating on 3720 only
Miscellaneous Correction
Corrective Action Required
08/09/2023
3722 - Gas line gauge reads 2 lbs at the start of inspection and does not have enough pressure for proper inspection - Anchor bolts in garage are not tightened down - Supply register above front porch ceiling needs seam tape applied at joint - Address broken plywood decking at rated assembly along the south wall ridge - Address repaired trusses in master bathroom and utility room - Install joist hangers in the master bedroom tray ceiling 2x4s that have a 12 foot span No improvements were made since last inspection. Have improvements completed before scheduling a follow up inspection. 08/09/2023 KBEARD 9:03AM
All Rough Inspection - Residential Passed 8/10/2023 8/10/2023 08/10/2023
Miscellaneous Correction
Resolved
08/10/2023
3722 - Gas line gauge reads 2 lbs at the start of inspection and does not have enough pressure for proper inspection - Anchor bolts in garage are not tightened down - Supply register above front porch ceiling needs seam tape applied at joint - Address broken plywood decking at rated assembly along the south wall ridge - Address repaired trusses in master bathroom and utility room - Install joist hangers in the master bedroom tray ceiling 2x4s that have a 12 foot span 3720 All passed Okay to start insulating on 3720 only
Miscellaneous Correction
Resolved
08/10/2023
3722 - Gas line gauge reads 2 lbs at the start of inspection and does not have enough pressure for proper inspection - Anchor bolts in garage are not tightened down - Supply register above front porch ceiling needs seam tape applied at joint - Address broken plywood decking at rated assembly along the south wall ridge - Address repaired trusses in master bathroom and utility room - Install joist hangers in the master bedroom tray ceiling 2x4s that have a 12 foot span No improvements were made since last inspection. Have improvements completed before scheduling a follow up inspection. 08/09/2023 KBEARD 9:03AM
Gas Service Inspection - Residential Passed 8/10/2023 08/10/2023
Miscellaneous Correction
Informational
08/08/2023
3726 and 3724 passed only. This is a partial pass only
Miscellaneous Correction
Resolved
08/10/2023
Gas gauge at 3722 read 2 lbs upon arrival and does not have enough pressure for a proper inspection 3720 passed
Erosion Control Inspection Residential Partial 8/10/2023 08/10/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/10/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Miscellaneous Correction
Resolved
08/10/2023
Perimeter erosion control is not in place. Erosion control must be in place before further inspections will be completed 08/02/2023. KBEARD
Miscellaneous Correction
Informational
08/10/2023
Erosion control is in place at all rough inspection. Erosion must be maintained until final occupancy
Rated Assembly Inspection Passed 8/10/2023 08/10/2023
Misc
Corrective Action Required
08/10/2023
3724 and 3726 both passed. This is a partial only
Misc
Corrective Action Required
08/10/2023
3722 Rated assembly decking by the south wall at the ridge has a hole that needs to be addressed 3720 Passed
Driveway Inspection Passed 8/14/2023 8/14/2023 08/18/2023
Misc
Informational
08/14/2023
8-14-23 BR Driveway is formed up and aggregate is place and compacted. Ready for concrete. 8-18-23 BR Driveway is constructed to LS specification
Sidewalk Inspection Passed 8/14/2023 8/14/2023 08/18/2023
Misc
Informational
08/14/2023
8-14-23 BR Sideway is formed up and aggregate is place and compacted. Ready for concrete. 8-18-23 BR Sidewalk is constructed to LS specification
Erosion Control Inspection Residential Failed 8/29/2023 08/29/2023
Miscellaneous Correction
Informational
08/10/2023
Erosion control is in place at all rough inspection. Erosion must be maintained until final occupancy
Miscellaneous Correction
Corrective Action Required
08/29/2023
Erosion control is missing, torn down or never installed. Full erosion control must be maintained until full CO. No inspections will be completed until full erosion control is in place. Clean street of dirt and gravel. 08/29/2023 KBEARD
All Rough Inspection - Residential Passed 9/1/2023 09/01/2023
Miscellaneous Correction
Informational
09/01/2023
Basement all rough passed
Occupancy Inspection - Codes Residential Failed 9/27/2023 9/27/2023 09/27/2023
Miscellaneous Correction
Corrective Action Required
09/27/2023
3722 Dishwasher is missing the anti hammer device Utility room plumbing is missing the anti hammer devices Attic access hatch is missing Garage to house self closing hinge is not working Garage to house door needs a secondary lock Basement stair to first platform coming up from the basement has a 1 inch in riser height difference, code allows only 3/8 of an inch in height difference Basement sump pump needs to state it is non GFCI protected Basement water is missing a anti siphon valve Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3724 Seal all penetrations at ceiling in garage above overhead door House to garage self closing hinge does not work Garage attic access hatch is not installed Seal all exterior penetrations Kitchen breaker #1 will not reset Attic access hatch upstairs is missing Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3720 and 3726 Not inspected. This is not a complete list This was for a TCO inspection only for 3722 and 3724
Erosion Control Inspection Residential Failed 9/27/2023 09/27/2023
Miscellaneous Correction
Informational
08/29/2023
Erosion control is in place at all rough inspection. Erosion must be maintained until final occupancy
Miscellaneous Correction
Corrective Action Required
08/29/2023
Erosion control is missing, torn down or never installed. Full erosion control must be maintained until full CO. No inspections will be completed until full erosion control is in place. Clean street of dirt and gravel. 08/29/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
09/27/2023
Erosion control is missing or torn down in some areas. Full erosion control must be maintained until full C of O
Occupancy Inspection - Codes Residential Failed 9/28/2023 9/28/2023 09/28/2023
Miscellaneous Correction
Informational
09/28/2023
3722 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3724 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3720 and 3726 Not inspected. This is not a complete list 3722 and 3724 both passed and are ready for a TCO only. 09/28/2023 KBEARD
Occupancy Inspection - Codes Residential Failed 9/29/2023 9/29/2023 09/29/2023
Miscellaneous Correction
Informational
09/28/2023
3722 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3724 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3720 and 3726 Not inspected. This is not a complete list 3722 and 3724 both passed and are ready for a TCO only. 09/28/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
09/29/2023
3720 Seal penetration in garage next to steps Seal vertical board at ceiling in garage Attic access hatch in garage is not in place Exterior sod and final grading is not complete Seal all exterior penetrations This occupancy inspection is for 3720 only
Occupancy Inspection - Codes Residential Failed 10/2/2023 10/2/2023 10/02/2023
Miscellaneous Correction
Informational
09/29/2023
3722 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3724 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3720 and 3726 Not inspected. This is not a complete list 3722 and 3724 both passed and are ready for a TCO only. 09/28/2023 KBEARD
Miscellaneous Correction
Informational
10/02/2023
3720 Exterior sod and final grading is not complete Seal all exterior penetrations This is a TCO for 3720 only Three units have been issued TCO only. Units 3720, 3722 and 3724 10/02/2023 KBEARD
Erosion Control Inspection Residential Passed 10/6/2023 10/06/2023
Miscellaneous Correction
Informational
09/27/2023
Erosion control is in place at all rough inspection. Erosion must be maintained until final occupancy
Miscellaneous Correction
Resolved
10/06/2023
Erosion control is missing, torn down or never installed. Full erosion control must be maintained until full CO. No inspections will be completed until full erosion control is in place. Clean street of dirt and gravel. 08/29/2023 KBEARD
Miscellaneous Correction
Resolved
10/06/2023
Erosion control is missing or torn down in some areas. Full erosion control must be maintained until full C of O
Plot Plan Inspection Passed 10/6/2023 10/06/2023
Occupancy Inspection - Codes Residential Failed 10/6/2023 10/6/2023 10/06/2023
Miscellaneous Correction
Informational
10/02/2023
3722 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3724 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3720 and 3726 Not inspected. This is not a complete list 3722 and 3724 both passed and are ready for a TCO only. 09/28/2023 KBEARD
Miscellaneous Correction
Informational
10/02/2023
3720 Exterior sod and final grading is not complete Seal all exterior penetrations This is a TCO for 3720 only Three units have been issued TCO only. Units 3720, 3722 and 3724 10/02/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
10/06/2023
3726 Handrail height on back porch exceeds 38 inches Basement closet under stairs needs a hatch installed Garage to house self closing hinge is not working as intended Seal all penetrations in garage ceiling Garage attic access hatch needs to be in place to check for proper seal Seal exterior penetrations of all units Permit is required on installed sprinkler systems on all units
Occupancy Inspection - Codes Residential Not Ready 10/12/2023 10/12/2023 10/12/2023
Miscellaneous Correction
Informational
10/06/2023
3722 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3724 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3720 and 3726 Not inspected. This is not a complete list 3722 and 3724 both passed and are ready for a TCO only. 09/28/2023 KBEARD
Miscellaneous Correction
Informational
10/06/2023
3720 Exterior sod and final grading is not complete Seal all exterior penetrations This is a TCO for 3720 only Three units have been issued TCO only. Units 3720, 3722 and 3724 10/02/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
10/06/2023
3726 Handrail height on back porch exceeds 38 inches Basement closet under stairs needs a hatch installed Garage to house self closing hinge is not working as intended Seal all penetrations in garage ceiling Garage attic access hatch needs to be in place to check for proper seal Seal exterior penetrations of all units Permit is required on installed sprinkler systems on all units
Miscellaneous Correction
Corrective Action Required
10/12/2023
3726 Handrail height on back porch exceeds 38 inches Basement closet under stairs needs a hatch installed Garage to house self closing hinge is not working as intended Seal all penetrations in garage ceiling Seal exterior penetrations of all units Permit is required on installed sprinkler systems on all units
Rated Assembly Inspection Passed 10/12/2023 10/12/2023
Misc
Resolved
10/12/2023
3724 and 3726 both passed. This is a partial only
Misc
Resolved
10/12/2023
3722 Rated assembly decking by the south wall at the ridge has a hole that needs to be addressed 3720 Passed
Occupancy Inspection - Codes Residential Ready for Temp CO 10/16/2023 10/16/2023 10/16/2023
Miscellaneous Correction
Informational
10/12/2023
3722 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3724 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3720 and 3726 Not inspected. This is not a complete list 3722 and 3724 both passed and are ready for a TCO only. 09/28/2023 KBEARD
Miscellaneous Correction
Informational
10/12/2023
3720 Exterior sod and final grading is not complete Seal all exterior penetrations This is a TCO for 3720 only Three units have been issued TCO only. Units 3720, 3722 and 3724 10/02/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
10/12/2023
3726 Handrail height on back porch exceeds 38 inches Basement closet under stairs needs a hatch installed Garage to house self closing hinge is not working as intended Seal all penetrations in garage ceiling Garage attic access hatch needs to be in place to check for proper seal Seal exterior penetrations of all units Permit is required on installed sprinkler systems on all units
Miscellaneous Correction
Corrective Action Required
10/12/2023
3726 Handrail height on back porch exceeds 38 inches Basement closet under stairs needs a hatch installed Garage to house self closing hinge is not working as intended Seal all penetrations in garage ceiling Seal exterior penetrations of all units Permit is required on installed sprinkler systems on all units
Miscellaneous Correction
Corrective Action Required
10/16/2023
3726 -Back porch handrail is still too high. Code is no more than 38 inches high from the tread nosing -all units need to have exterior penetrations sealed -3726 needs to have the exterior sump pump extension replaced (it’s broken) All units now have a TCO issued 10/16/2023 KBEARD
Occupancy Inspection - Codes Residential Full C of O 10/17/2023 10/18/2023 10/18/2023
Miscellaneous Correction
Informational
10/16/2023
3722 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3724 Sod is not installed Water meter height was not checked due to final grading not being completed Seal all exterior penetrations 3720 and 3726 Not inspected. This is not a complete list 3722 and 3724 both passed and are ready for a TCO only. 09/28/2023 KBEARD
Miscellaneous Correction
Informational
10/16/2023
3720 Exterior sod and final grading is not complete Seal all exterior penetrations This is a TCO for 3720 only Three units have been issued TCO only. Units 3720, 3722 and 3724 10/02/2023 KBEARD
Miscellaneous Correction
Resolved
10/18/2023
3726 Handrail height on back porch exceeds 38 inches Basement closet under stairs needs a hatch installed Garage to house self closing hinge is not working as intended Seal all penetrations in garage ceiling Garage attic access hatch needs to be in place to check for proper seal Seal exterior penetrations of all units Permit is required on installed sprinkler systems on all units
Miscellaneous Correction
Resolved
10/18/2023
3726 Handrail height on back porch exceeds 38 inches Basement closet under stairs needs a hatch installed Garage to house self closing hinge is not working as intended Seal all penetrations in garage ceiling Seal exterior penetrations of all units Permit is required on installed sprinkler systems on all units
Miscellaneous Correction
Partial Correction
10/18/2023
3726 -Back porch handrail is still too high. Code is no more than 38 inches high from the tread nosing -all units need to have exterior penetrations sealed -3726 needs to have the exterior sump pump extension replaced (it’s broken) All units now have a TCO issued 10/16/2023 KBEARD
Documents & Images
Date Uploaded File Type Document Name
07/12/2021 OS #9 - PERMIT APP
07/13/2021 Approved Plans Approved Truss Package
07/13/2021 Permit Codes Residential Plan Review
07/13/2021 Permit DS Building Permit
07/13/2021 Receipt Receipt for transaction:2021-005598
07/21/2021 Plot Plan Approved Revised Plot Plan
08/23/2021 Approved Plans APPROVED TRUSS LAYOUT
10/22/2021 Receipt Receipt for transaction: 2021-008192
11/24/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/20/2022 Approved Plans Approved Drawings
01/24/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/27/2022 Approved Plans Approved Drawings
01/28/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
06/29/2022 Plot Plan Approved Plot Plan
06/29/2022 Approved Plans Approved Drawings
04/04/2023 Approved Plans APPROVED PLANS
04/04/2023 Approved Plans approved plot plan
04/04/2023 Approved Plans APPROVED TRUSS LAYOUT
04/04/2023 Approved Plans APPROVED TRUSS PACKAGE
06/19/2023 Approved Plans APPROVED PLAN UPDATES
07/31/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
08/03/2023 I59370388_P230292-01
08/03/2023 9 OSAGE - 230801
08/04/2023 Letter INSPECTION SUMMARY
08/08/2023 Letter INSPECTION SUMMARY
08/08/2023 Letter INSPECTION SUMMARY
08/08/2023 Letter INSPECTION SUMMARY
08/09/2023 Letter INSPECTION SUMMARY
08/09/2023 Letter INSPECTION SUMMARY
08/10/2023 Letter INSPECTION SUMMARY
08/10/2023 Letter INSPECTION SUMMARY
08/10/2023 Letter INSPECTION SUMMARY
08/14/2023 Letter INSPECTION SUMMARY
08/14/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/21/2023 OS 9- Basement finish App
08/21/2023 OS #9 - Juneau - Farmhouse - Basement Finish - 08_17_23
08/22/2023 Approved Plans 3726 FINISHED BASEMENT PLAN
08/22/2023 Application Form APPLICATION
08/25/2023 Receipt Receipt for transaction:2023-006598
08/29/2023 Letter INSPECTION SUMMARY
09/01/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
09/29/2023 Letter INSPECTION SUMMARY
10/02/2023 Letter INSPECTION SUMMARY
10/06/2023 Letter INSPECTION SUMMARY
10/06/2023 Letter INSPECTION SUMMARY
10/06/2023 Letter INSPECTION SUMMARY
10/12/2023 Letter INSPECTION SUMMARY
10/12/2023 Letter INSPECTION SUMMARY
10/16/2023 Letter INSPECTION SUMMARY
10/17/2023 Certificate/License Codes Temporary Certificate of Occupancy
10/17/2023 Receipt Receipt for transaction:2023-007831
10/18/2023 Letter Codes Final Certificate of Occupancy
10/18/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home