Permit Application Status

PRRES20213082


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213082
Building Permit - Residential
Certificate of Occupancy
D AND D BUILDING INC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK SUSPENDED SLAB
06/15/2021
06/23/2021
12/14/2021
10/10/2022
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
TOM.ELDER.DANDD@GMAIL.COM  
D AND D BUILDING INC, Address:1100 NE DELTA SCHOOL RD  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
TEAGUE ELECTRIC CONSTRUCTION LLC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,137.16 $1,137.16 Paid 06/23/2021
Right of Way Permit Fee $80.00 $80.00 Paid 06/23/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/23/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 06/23/2021
Water Meter Fee $455.54 $455.54 Paid 06/23/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 06/23/2021
Temporary Occupancy Fee $50.00 $50.00 Paid 07/25/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 7/23/2021 (9:45) 7/23/2021 07/23/2021
Misc
Corrective Action Required
07/23/2021
-NO INSPECTION. PROVIDE EROSION CONTROL PER REQUIREMENT
Erosion Control Inspection Residential Failed 7/23/2021 07/23/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/23/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Footing Inspection - Residential Passed 7/23/2021 (1:15) 7/23/2021 07/23/2021
Misc
Resolved
07/23/2021
-NO INSPECTION. PROVIDE EROSION CONTROL PER REQUIREMENT
Underslab Plumbing Inspection - Residential Passed 8/31/2021 8/31/2021 08/31/2021
Sewer Service Inspection - R Passed 9/20/2021 (8:45) 9/20/2021 09/20/2021
Water Service Inspection - R Passed 9/21/2021 (9:00) 9/21/2021 09/21/2021
Suspended Slab Inspection Failed 11/16/2021 11/16/2021
Misc
Corrective Action Required
11/16/2021
-Install corner rebars per plan -Fasten decking to steel beam per plan -The rebars in the corrugation should be about 2” of bottom of decking. The 10 ft rebar a along the I beam are ok. See plan detail
Suspended Slab Inspection Failed 11/22/2021 (9:30) 11/22/2021 11/22/2021
Misc
Corrective Action Required
11/16/2021
-Install corner rebars per plan -Fasten decking to steel beam per plan **Have Apex engimeer address the 36"x36" I beam support pad and I beam not present at NW side of garage
Suspended Slab Inspection Partial 11/24/2021 11/24/2021
Misc
Corrective Action Required
11/22/2021
**Have Apex engimeer address the 36"x36" I beam support pad and I beam not present at NW side of garage
All Rough Inspection - Residential Failed 12/22/2021 12/22/2021 12/22/2021
Misc
Informational
12/22/2021
Partial framing inspection for covered deck framing and garage PFH portal framing-Ok to cover
Electrical Service Inspection Passed 3/16/2022 3/16/2022 03/16/2022
All Rough Inspection - Residential Failed 3/16/2022 3/16/2022 03/16/2022
Misc
Resolved
03/16/2022
Partial framing inspection for covered deck framing and garage PFH portal framing-Ok to cover
Misc
Corrective Action Required
03/16/2022
-Install front door per security code -Anchor steel columns in garage -Protect water lines to garage hose bibs -Provide CS-PF walls at breakfast per plan -Complete framing at fireplace and secure fireplace to framing -Nail siding at CS-PF walls to header and rim band per plan -Brace interior walls per plan -Protect wiring at master bedroom below windows -Provide vertical fire blocking at rear basement rec room wall no more than ten ft apart; vertical fire blockings sheathing must be min 3/4”; fb gaps at top&bottom of vertical fire blockings; Fb basement bedroom and bathroom wall from soffit -Provide blockings every 4 ft along the joists adjacent to exterior wall to replace ones that were removed for ducting -Cannot vent tub trap and toilet together. Install a separate vent for the tub trap to wet-vent the toilet (bathroom closer to front bedroom) **OK TO INSULATE
Gas Service Inspection - Residential Passed 3/16/2022 3/16/2022 03/16/2022
All Rough Inspection - Residential Failed 3/30/2022 3/30/2022 03/30/2022
Misc
Corrective Action Required
03/16/2022
-Install front door per security code -Provide CS-PF walls at breakfast per plan **Plan shows CSPF walls with min double 2x12 header spanning wall corner to corner **Or get engineer of the plan to address **OK TO INSULATE **PLEASE SUBMIT APEX ENGINEER LETTER ADDRESSING SUSPENDED SLAB INSPECTION ISSUES (MISSING PAD AND I BEAM)
Suspended Slab Inspection Passed 4/4/2022 (11:15) 4/4/2022 04/04/2022
Misc
Corrective Action Required
11/24/2021
**Have Apex engimeer address the 36"x36" I beam support pad and I beam not present at NW side of garage
All Rough Inspection - Residential Passed 4/14/2022 4/14/2022 04/14/2022
Misc
Resolved
04/14/2022
**PLEASE SUBMIT APEX ENGINEER LETTER ADDRESSING SUSPENDED SLAB INSPECTION ISSUES (MISSING PAD AND I BEAM)
Driveway Inspection Partial 6/15/2022 6/15/2022 06/15/2022
Misc
Informational
06/15/2022
6-15-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 6/17/2022 6/17/2022 06/27/2022
Misc
Informational
06/15/2022
6-15-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
06/27/2022
6-27-22 AN driveway looks good and has expansion joints at curb and right of way. No sidewalk
Erosion Control Inspection Residential Passed 07/19/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/23/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 7/19/2022 7/19/2022 07/19/2022
Misc
Resolved
07/19/2022
**Have Apex engimeer address the 36"x36" I beam support pad and I beam not present at NW side of garage
Misc
Corrective Action Required
07/19/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city -Raised water meter to final grade level. Meter-to-lidi distance is 14”-18” -Deck piers not approved on record -Nail deck joist hangers ; attach deck beam to each post with two 1/2” through bolts or equivalence; fasten deck posts to support bases -Final grade, sod, downspout and sump pump extension -Seal above meter, AC disconnect, seal exterior lights, etc -Provide sewer tracer wire port at grade -Provide box extension for all electrical boxes recessed more than 1/4” behind non-combustible wall finish -Complete installing kitchen hood and hookup of gas cooktop -Secure electrical under cooktop -Complete all kitchen island plumbing and electrical -Complete bathroom fan installation at main floor -Provide a gfci-protected receptacle in separate unfinished portion of basement outside under-garage space -Anchor all basement columns to floor -Receptacle located within six ft of the sink in under-garage space must be gfci-protected. No exception for dedicated receptacle -Install water pressure reducer at water service -Secure water service pex to wall -Provide airtight plug for sewer clean out -Extend water heater PT pipe down to within 6” of floor
Occupancy Inspection - Codes Residential Failed 7/21/2022 7/21/2022 07/21/2022
Misc
Corrective Action Required
07/19/2022
-Obtain lawn irrigation permit -Deck piers not approved on record **please submit engineer letter for the deck pier -Nail deck joist hangers ; attach deck beam to each post with two 1/2” through bolts or equivalence -Final grade, sod, sump pump extension
Piers/Caissons Inspection - Residential Passed 7/22/2022 7/22/2022 07/22/2022
Informational
07/22/2022
One pier was exposed for inspection. Pier size and frost depth verified to be compliant with approved plan
Occupancy Inspection - Codes Residential Ready for Temp CO 7/22/2022 07/22/2022
Misc
Corrective Action Required
07/21/2022
-Obtain lawn irrigation permit -Final grade, sod, sump pump extension
Occupancy Inspection - Codes Residential Temporary C of O 07/25/2022
Misc
Corrective Action Required
07/22/2022
-Obtain lawn irrigation permit -Final grade, sod, sump pump extension
Occupancy Inspection - Codes Residential Full C of O 10/10/2022 10/10/2022
Misc
Resolved
10/10/2022
-Obtain lawn irrigation permit -Final grade, sod, sump pump extension
Documents & Images
Date Uploaded File Type Document Name
06/15/2021 Application Form Permit Application and License Tax Form
06/16/2021 Approved Plans Approved Suspended Slab Drawings
06/17/2021 Permit Codes Residential Plan Review
06/17/2021 Approved Plans Approved Drawings
06/22/2021 Plot Plan Approved Plot Plan
06/22/2021 Permit Codes Residential Plan Review
06/23/2021 Permit DS Building Permit
06/23/2021 Receipt Receipt for transaction:2021-004876
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter INSPECTION SUMMARY
11/22/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/13/2022 21-002-26 DD-7165 Alternate Lateral Bracing Analysis
04/19/2022 Final-2021_12_01-Struct-LSMO-Shaw Construction
04/28/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
07/25/2022 Receipt Receipt for transaction:2022-006066
07/25/2022 Letter Codes Temporary Certificate of Occupancy
10/10/2022 Letter Codes Final Certificate of Occupancy
10/10/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home