Permit Application Status

PRRES20212957


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212957
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES
06/09/2021
06/14/2021
10/13/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 06/14/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/14/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/14/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/14/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/14/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/14/2021
9110078-Valuation Fee New Single Family $1,605.70 $1,605.70 Paid 06/14/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/30/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/23/2021 9/23/2021 09/23/2021
Misc
Informational
09/23/2021
APPROVED PER BRADLEY HUXOL 7/13/21
Underslab Plumbing Inspection - Residential Passed 9/23/2021 9/23/2021 09/23/2021
Gas Service Inspection - Residential Passed 4/8/2022 4/8/2022 04/08/2022
Electrical Service Inspection Passed 4/8/2022 4/8/2022 04/08/2022
All Rough Inspection - Residential Failed 4/8/2022 4/8/2022 04/08/2022
Misc
Corrective Action Required
04/08/2022
-nail exterior sheathing garage portal PFH per plans -provide (2) nail each stud of LIB bracing strap -address the HVAC box out chase east corner garage wall, dbl top plate removed for duct, and bearing for trpl joist to right of duct -solid block all sheathing breaks -12” oc nailing all abutting and intersecting corners -fur down for DWV above front entry -(4) 2X stud pack all girder trusses bearing ends per plans -1st floor laundry (6) 2x4 stud pack for 2nd floor girder trusses bearing per plans -LIB bracing all locations per plans -exterior bracing great room windows per plans, OSB panel, 8D nails 6” edge 12” field, blocking mid height wall, cont over rim joist min 9 1/4” lap, attach sheathing 8D nails 3” oc top and bottom rim joist -CS-PF bracing design dining room sliding glass door, nail all exterior sheathing per design, see plans/IRC R602.10.6.4 for reference -(6) 2x6 stud pack girder trusses bearing kitchen near fridge per plans -address dbl girder trusses above sliding glass door H2.5 clipped to 12” vert 2x4s toenailed to top plate, proper restraint and uplift resistance not provided by blocks -top to top plate connection per code, address great room window exterior wall top plate corners not lapped at ends for connection to plates with different wall heights at master bed and dining room -attic access at garage per plans -all truss hangers per plans -all truss lateral bracing per plans -dbl top plate requires min 24” offset between plate breaks - see 2nd floor stairs -(6) 2x6 stud pack girder trusses bearing end 2nd floor stair wall per plans and (6) 2x4 stud pack at bed #2 bearing end -(2) 2x12 header corner to corner with exterior bracing per plans at stair wall window -attic access required for kitchen/dining area/font bedroom 1st floor -address floor joist above service panel basement bored for NM to service panel, bores for NM less than 2” from end of joist -address floor joist over notched for DWV west side basement -provide (4) 2x6 stud pack at W8x21 beam west side basement per plans - 4” diameter SCH 40 steel column at W10x26 steel beam per plans -3.5” diameter SCH 40 steel column at W10x26 steel beam pier “F” per plans -(3) 2x4 stud pack pier “A” stair wall per plans
Sewer Service Inspection - R Passed 4/11/2022 (1:30) 4/11/2022 04/11/2022
Water Service Inspection - R Passed 4/13/2022 (1:30) 4/13/2022 04/13/2022
All Rough Inspection - Residential Passed 4/21/2022 4/21/2022 04/21/2022
Misc
Corrective Action Required
04/08/2022
*****4-21-22 HOUSE INSULATED WITHOUT APPROVAL. REMOVE ALL INSULATION FOR INSPECTION -nail exterior sheathing garage portal PFH per plans -provide (2) nail each stud of LIB bracing strap -address the HVAC box out chase east corner garage wall, dbl top plate removed for duct, and bearing for trpl joist to right of duct -solid block all sheathing breaks -12” oc nailing all abutting and intersecting corners -fur down for DWV above front entry -(4) 2X stud pack all girder trusses bearing ends per plans -1st floor laundry (6) 2x4 stud pack for 2nd floor girder trusses bearing per plans -LIB bracing all locations per plans -exterior bracing great room windows per plans, OSB panel, 8D nails 6” edge 12” field, blocking mid height wall, cont over rim joist min 9 1/4” lap, attach sheathing 8D nails 3” oc top and bottom rim joist -CS-PF bracing design dining room sliding glass door, nail all exterior sheathing per design, see plans/IRC R602.10.6.4 for reference -(6) 2x6 stud pack girder trusses bearing kitchen near fridge per plans -address dbl girder trusses above sliding glass door H2.5 clipped to 12” vert 2x4s toenailed to top plate, proper restraint and uplift resistance not provided by blocks -top to top plate connection per code, address great room window exterior wall top plate corners not lapped at ends for connection to plates with different wall heights at master bed and dining room -attic access at garage per plans -all truss hangers per plans -all truss lateral bracing per plans -dbl top plate requires min 24” offset between plate breaks - see 2nd floor stairs -(6) 2x6 stud pack girder trusses bearing end 2nd floor stair wall per plans and (6) 2x4 stud pack at bed #2 bearing end -(2) 2x12 header corner to corner with exterior bracing per plans at stair wall window -attic access required for kitchen/dining area/font bedroom 1st floor -address floor joist above service panel basement bored for NM to service panel, bores for NM less than 2” from end of joist -address floor joist over notched for DWV west side basement -provide (4) 2x6 stud pack at W8x21 beam west side basement per plans - 4” diameter SCH 40 steel column at W10x26 steel beam per plans -3.5” diameter SCH 40 steel column at W10x26 steel beam pier “F” per plans -(3) 2x4 stud pack pier “A” stair wall per plans
All Rough Inspection - Residential Not Ready 04/29/2022
Miscellaneous Correction
Corrective Action Required
04/29/2022
*****4-21-22 HOUSE INSULATED WITHOUT APPROVAL. REMOVE ALL INSULATION FOR INSPECTION -nail exterior sheathing garage portal PFH per plans -provide (2) nail each stud of LIB bracing strap -address the HVAC box out chase east corner garage wall, dbl top plate removed for duct, and bearing for trpl joist to right of duct -solid block all sheathing breaks -12” oc nailing all abutting and intersecting corners -fur down for DWV above front entry -(4) 2X stud pack all girder trusses bearing ends per plans -1st floor laundry (6) 2x4 stud pack for 2nd floor girder trusses bearing per plans -LIB bracing all locations per plans -exterior bracing great room windows per plans, OSB panel, 8D nails 6” edge 12” field, blocking mid height wall, cont over rim joist min 9 1/4” lap, attach sheathing 8D nails 3” oc top and bottom rim joist -CS-PF bracing design dining room sliding glass door, nail all exterior sheathing per design, see plans/IRC R602.10.6.4 for reference -(6) 2x6 stud pack girder trusses bearing kitchen near fridge per plans -address dbl girder trusses above sliding glass door H2.5 clipped to 12” vert 2x4s toenailed to top plate, proper restraint and uplift resistance not provided by blocks -top to top plate connection per code, address great room window exterior wall top plate corners not lapped at ends for connection to plates with different wall heights at master bed and dining room -attic access at garage per plans -all truss hangers per plans -all truss lateral bracing per plans -dbl top plate requires min 24” offset between plate breaks - see 2nd floor stairs -(6) 2x6 stud pack girder trusses bearing end 2nd floor stair wall per plans and (6) 2x4 stud pack at bed #2 bearing end -(2) 2x12 header corner to corner with exterior bracing per plans at stair wall window -attic access required for kitchen/dining area/font bedroom 1st floor -address floor joist above service panel basement bored for NM to service panel, bores for NM less than 2” from end of joist -address floor joist over notched for DWV west side basement -provide (4) 2x6 stud pack at W8x21 beam west side basement per plans - 4” diameter SCH 40 steel column at W10x26 steel beam per plans -3.5” diameter SCH 40 steel column at W10x26 steel beam pier “F” per plans -(3) 2x4 stud pack pier “A” stair wall per plans
Driveway Inspection Partial 5/4/2022 05/04/2022
Misc
Informational
05/04/2022
On 5.4.2022 I performed a driveway inspection and pass the subgrade to pour concrete.
Sidewalk Inspection Partial 5/4/2022 05/04/2022
Misc
Informational
05/04/2022
On 5.4.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete.
All Rough Inspection - Residential Failed 5/5/2022 5/5/2022 05/05/2022
Miscellaneous Correction
Corrective Action Required
04/29/2022
****5/5/22 - UNABLE TO PERFORM INSPECTION IN CURRENT CONDITION, MOVE ALL INSULATION TO MIDDLE OF EACH ROOM AND STACK *****4-21-22 HOUSE INSULATED WITHOUT APPROVAL. REMOVE ALL INSULATION FOR INSPECTION -nail exterior sheathing garage portal PFH per plans -provide (2) nail each stud of LIB bracing strap -address the HVAC box out chase east corner garage wall, dbl top plate removed for duct, and bearing for trpl joist to right of duct -solid block all sheathing breaks -12” oc nailing all abutting and intersecting corners -fur down for DWV above front entry -(4) 2X stud pack all girder trusses bearing ends per plans -1st floor laundry (6) 2x4 stud pack for 2nd floor girder trusses bearing per plans -LIB bracing all locations per plans -exterior bracing great room windows per plans, OSB panel, 8D nails 6” edge 12” field, blocking mid height wall, cont over rim joist min 9 1/4” lap, attach sheathing 8D nails 3” oc top and bottom rim joist -CS-PF bracing design dining room sliding glass door, nail all exterior sheathing per design, see plans/IRC R602.10.6.4 for reference -(6) 2x6 stud pack girder trusses bearing kitchen near fridge per plans -address dbl girder trusses above sliding glass door H2.5 clipped to 12” vert 2x4s toenailed to top plate, proper restraint and uplift resistance not provided by blocks -top to top plate connection per code, address great room window exterior wall top plate corners not lapped at ends for connection to plates with different wall heights at master bed and dining room -attic access at garage per plans -all truss hangers per plans -all truss lateral bracing per plans -dbl top plate requires min 24” offset between plate breaks - see 2nd floor stairs -(6) 2x6 stud pack girder trusses bearing end 2nd floor stair wall per plans and (6) 2x4 stud pack at bed #2 bearing end -(2) 2x12 header corner to corner with exterior bracing per plans at stair wall window -attic access required for kitchen/dining area/font bedroom 1st floor -address floor joist above service panel basement bored for NM to service panel, bores for NM less than 2” from end of joist -address floor joist over notched for DWV west side basement -provide (4) 2x6 stud pack at W8x21 beam west side basement per plans - 4” diameter SCH 40 steel column at W10x26 steel beam per plans -3.5” diameter SCH 40 steel column at W10x26 steel beam pier “F” per plans -(3) 2x4 stud pack pier “A” stair wall per plans
All Rough Inspection - Residential Failed 5/11/2022 5/11/2022 05/11/2022
Miscellaneous Correction
Corrective Action Required
05/05/2022
-provide (2) nail each stud of LIB bracing strap (can’t confirm rock and insulation blocking) -(4) 2X stud pack all girder trusses bearing ends per plans -LIB bracing all locations per plans -exterior bracing great room windows per plans, OSB panel, 8D nails 6” edge 12” field, blocking mid height wall, cont over rim joist min 9 1/4” lap, attach sheathing 8D nails 3” oc top and bottom rim joist -CS-PF bracing design dining room sliding glass door, nail all exterior sheathing per design, see plans/IRC R602.10.6.4 for reference -(6) 2x6 stud pack girder trusses bearing kitchen near fridge per plans -address dbl girder trusses above sliding glass door H2.5 clipped to 12” vert 2x4s toenailed to top plate, proper restraint and uplift resistance not provided by blocks -all truss hangers per plans -all truss lateral bracing per plans -connect all ducts at bath exhaust fans to vent to exterior -dbl top plate requires min 24” offset between plate breaks - see 2nd floor stairs -(6) 2x6 stud pack girder trusses bearing end 2nd floor stair wall per plans -attic access required for kitchen/dining area/font bedroom 1st floor, attic access requires 30” vertical clearance **DO NOT INSULATE**
All Rough Inspection - Residential Failed 5/16/2022 5/16/2022 05/16/2022
Miscellaneous Correction
Corrective Action Required
05/11/2022
-LIB bracing all locations per plans, (have engineer clarify location LIB bracing at closet master bed hall) -land all electrical to boxes and secure NM at areas removed for girder truss stud pack kitchen and 2nd floor stairs OK FOR INSULATION
Erosion Control Inspection Residential Partial 5/16/2022 5/16/2022 05/16/2022
All Rough Inspection - Residential Passed 5/19/2022 5/19/2022 05/19/2022
Miscellaneous Correction
Resolved
05/19/2022
-LIB bracing all locations per plans, (have engineer clarify location LIB bracing at closet master bed hall) -land all electrical to boxes and secure NM at areas removed for girder truss stud pack kitchen and 2nd floor stairs OK FOR INSULATION
Occupancy Inspection - Codes Residential Not Ready 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
06/06/2022
NOT READY FOR OCCUPANCY INSPECTION
Occupancy Inspection - Codes Residential Failed 9/23/2022 9/23/2022 09/23/2022
Misc
Corrective Action Required
06/06/2022
-resolve outstanding inspection fees -final driveway and sidewalk inspections required -provide guardrail front porch -splash blocks -Sump pump min 36” discharge -open NM kitchen counter -install vanity light 2nd floor bath -(2) 1/2” through bolts each post/beam connection at deck -seal all penetrations in siding, seal across top of AC disconnect and meter can -correct grade at front of yard, negative slope towards lawn irrigation control -provide gravel base at water meter pit
Driveway Inspection Passed 9/28/2022 9/28/2022 09/28/2022
Misc
Informational
05/04/2022
On 5.4.2022 I performed a driveway inspection and pass the subgrade to pour concrete. 9-28-22 RH. Driveway passed LS and ADA Specification.
Sidewalk Inspection Passed 9/28/2022 9/28/2022 09/28/2022
Misc
Informational
05/04/2022
On 5.4.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete. 9-28-22 RH. Sidewalk passed LS and ADA specification.
Erosion Control Inspection Residential Passed 9/29/2022 9/29/2022 09/29/2022
Plot Plan Inspection Passed 9/29/2022 9/29/2022 09/29/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 9/29/2022 9/29/2022 09/29/2022
Misc
Corrective Action Required
09/23/2022
-correct grade at front of yard, negative slope towards lawn irrigation control -remove old silt fence and construction debris rear of lot
Occupancy Inspection - Codes Residential Temporary C of O 10/3/2022 10/3/2022 09/30/2022
Misc
Corrective Action Required
09/29/2022
-correct grade at front of yard, negative slope towards lawn irrigation control -remove old silt fence and construction debris rear of lot
Occupancy Inspection - Codes Residential Failed 10/7/2022 10/7/2022 10/07/2022
Misc
Corrective Action Required
09/30/2022
-replace sod at front of lot
Occupancy Inspection - Codes Residential Full C of O 10/13/2022 10/13/2022 10/13/2022
Misc
Resolved
10/13/2022
Documents & Images
Date Uploaded File Type Document Name
06/09/2021 Approved Plans APPROVED PLANS
06/09/2021 Approved Plans APPROVED TRUSS DRAWINGS
06/09/2021 Approved Plans APPROVED TRUSS LAYOUT
06/10/2021 Permit Codes Residential Plan Review
06/14/2021 Plot Plan APPROVED PLOT PLAN
06/14/2021 Permit Codes Residential Plan Review
06/14/2021 Permit DS Building Permit
06/14/2021 Receipt Receipt for transaction:2021-004343
09/22/2021 Lot 88 Reserve at Stoney Creek Founation Inspection
09/22/2021 88 Reserve at Stoney Creek FTNG
09/23/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/14/2022 RR 88 Letter
04/21/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/16/2022 88 Reserve at Stoney Creek Letter #2
05/16/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/18/2022 88 Reserve at Stoney Creek Letter #3
05/19/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/28/2022 Receipt Receipt for transaction:2022-007862
09/28/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/29/2022 Letter INSPECTION SUMMARY
09/29/2022 Letter INSPECTION SUMMARY
09/30/2022 Receipt Receipt for transaction:2022-007924
09/30/2022 Letter Codes Temporary Certificate of Occupancy
10/07/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter Field Certificate of Occupancy
10/13/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home