Summary
PRRES20212858
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - UNCOVERED PATIO
06/03/2021
06/08/2021
12/01/2021
06/13/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $929.16 $929.16 Paid 06/08/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/08/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/08/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/08/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/08/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/08/2021
8331504-EFHB Middle Big Creek, Full $468.72 $468.72 Paid 10/22/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/2/2021 9/2/2021 09/02/2021
Misc
Corrective Action Required
09/02/2021
APPROVED PER DAVID P AINSWORTH 8/25/21
Underslab Plumbing Inspection - Residential Passed 9/23/2021 9/23/2021 09/23/2021
Sewer Service Inspection - R Passed 12/30/2021 12/30/2021
Misc
Informational
12/30/2021
OK SEWER LINE, DO NOT COVER, FOOTING HAS BEEN UNDERMINED FOR EXACAVATION, HAVE ENGINEER ADDRESS FOOTING
Footing Inspection - Residential Failed 12/30/2021 12/30/2021 12/30/2021
Misc
Corrective Action Required
12/30/2021
FOOTING HAS BEEN UNDERMINED FOR SEWER LINE EXCAVATION, DO NOT COVER, HAVE ENGINEER ADDRESS FOOTING
Water Service Inspection - R Passed 1/5/2022 (10:15) 1/5/2022 01/05/2022
Electrical Service Inspection Failed 2/8/2022 2/8/2022 02/08/2022
Misc
Corrective Action Required
02/08/2022
-replace acorn style clamp with clamp rated for rebar connection GEC to UFER
Gas Service Inspection - Residential Failed 2/8/2022 2/8/2022 02/08/2022
Misc
Corrective Action Required
02/08/2022
-Gas line bond required pressure ok
All Rough Inspection - Residential Failed 2/8/2022 2/8/2022 02/08/2022
Misc
Corrective Action Required
02/08/2022
-Maintain gravel filter on drive -Upload engineer reports to portal concerning undermined footing at sewer line install -Fireblock deadspace at pantry -address (2) joists overbored and bored less than 2” from end of joist for DWV at kitchen -security blocking front door latch side -address dbl top plate less than 24” offset between breaks at front window at foyer -attic access garage per plans -fireblock HVAC chase at great room and 2nd floor hall -shim all studs with gap at plate, 2x6 entry wall -Structural straps at all top plates bored 50% or more at all interior load bearing walls and all exterior walls -anchor bolt required within 12” of plate break, basement stair wall -nail off all joist hangers at basement -gas line bond required -replace acorn style clamp at UFER with one rated for rebar connection GEC -land electrical at basement stair wall -(2) 2x10 floor joist at basement egress window per plans
Electrical Service Inspection Passed 2/22/2022 2/22/2022 02/22/2022
Misc
Resolved
02/22/2022
-replace acorn style clamp with clamp rated for rebar connection GEC to UFER
Gas Service Inspection - Residential Failed 2/22/2022 2/22/2022 02/22/2022
Misc
Corrective Action Required
02/08/2022
-Gas line bond required pressure ok
All Rough Inspection - Residential Failed 2/22/2022 2/22/2022 02/22/2022
Misc
Corrective Action Required
02/08/2022
-Upload engineer reports to portal concerning undermined footing at sewer line install -gas line bond required -land electrical at basement stair wall
Footing Inspection - Residential Passed 2/25/2022 2/25/2022 02/25/2022
Misc
Resolved
02/25/2022
Erosion Control Inspection Residential Partial 2/25/2022 2/25/2022 02/25/2022
Misc
Corrective Action Required
02/25/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Gas Service Inspection - Residential Passed 2/25/2022 2/25/2022 02/25/2022
Misc
Resolved
02/25/2022
All Rough Inspection - Residential Passed 2/25/2022 2/25/2022 02/25/2022
Misc
Resolved
02/25/2022
Sidewalk Inspection Partial 4/7/2022 4/7/2022 04/07/2022
Misc
Informational
04/07/2022
On 4.7.2022 Thursday I performed a sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 4/6/2022 4/6/2022 04/22/2022
Misc
Informational
04/06/2022
On Wednesday 4.6.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Passed 4/22/2022 4/22/2022 04/22/2022
Misc
Informational
04/07/2022
On 4.7.2022 Thursday I performed a sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 04/22/2022
Misc
Informational
04/06/2022
On Wednesday 4.6.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
05/05/2022
-Submit as graded plot plan for review and approval - final grade and sod -gutters and downspouts required -provide splash blocks downspouts and sump pump discharge, min 36" discharge from foundation -secure AC electrical whip within 12" of disconnect -garage door must be self closing -install sliding glass door hardware, secondary toe lock required -install spindles at 2nd floor stairs -utility GFCI receptacle at basement wall within 25’ of furnace -complete guardrail front porch
Occupancy Inspection - Codes Residential Temporary C of O 5/6/2022 5/6/2022 05/06/2022
Misc
Corrective Action Required
05/05/2022
-Submit as graded plot plan for review and approval - final grade and sod -gutters and downspouts required -provide splash blocks downspouts and sump pump discharge, min 36" discharge from foundation -secure AC electrical whip within 12" of disconnect **OK FOR TCO, TCO EXPIRES 6/6/22**
Erosion Control Inspection Residential Partial 5/6/2022 5/6/2022 05/06/2022
Misc
Corrective Action Required
02/25/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Temporary C of O 5/26/2022 05/26/2022
Misc
Corrective Action Required
05/06/2022
-Submit as graded plot plan for review and approval - final grade and sod -gutters and downspouts required -provide splash blocks downspouts and sump pump discharge, min 36" discharge from foundation -secure AC electrical whip within 12" of disconnect -correct water meter
Water Service Inspection - R Passed 6/3/2022 (1:30) 6/3/2022 06/03/2022
Plot Plan Inspection Passed 06/13/2022
Erosion Control Inspection Residential Passed 06/13/2022
Misc
Resolved
06/13/2022
Occupancy Inspection - Codes Residential Full C of O 6/13/2022 6/13/2022 06/13/2022
Misc
Resolved
06/13/2022
Documents & Images
Date Uploaded File Type Document Name
06/03/2021 OS #39 - PERMIT APP
06/04/2021 Permit Codes Residential Plan Review
06/04/2021 Approved Plans Approved Drawings
06/04/2021 Approved Plans Approved Truss Layout
06/04/2021 Approved Plans Approved Truss Package
06/07/2021 Plot Plan Approved Plot Plan
06/07/2021 Permit Codes Residential Plan Review
06/08/2021 Permit DS Building Permit
06/08/2021 Receipt Receipt for transaction:2021-004107
09/01/2021 2110 SW Rutherfrodd Dr LSMO Osage Lot 39 Clayton Prop P 2021-2858 3rd Party Footing Inspection Report 8-25-21
09/02/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
12/30/2021 Letter INSPECTION SUMMARY
12/30/2021 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/22/2022 39 osage letter
02/22/2022 39 Osage-Undermined FTNG
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/24/2022 39 Osage-AB3 Confirmation
02/25/2022 Letter INSPECTION SUMMARY
02/25/2022 Letter INSPECTION SUMMARY
02/25/2022 Letter INSPECTION SUMMARY
02/25/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter Codes Temporary Certificate of Occupancy
05/06/2022 Letter INSPECTION SUMMARY
05/26/2022 Email Osage Single Family Water Meters and TCO's
05/26/2022 Letter Codes Temporary Certificate of Occupancy
06/03/2022 Letter INSPECTION SUMMARY
06/13/2022 LOT 39 ASBUILT
06/13/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter Codes Final Certificate of Occupancy
06/13/2022 Letter Field Certificate of Occupancy
01/29/2024 LOT 39 ASBUILT
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home