Permit Application Status

PRRES20212780


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212780
Building Permit - Residential
Certificate of Occupancy
ACH DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO - SUSPENDED STOOP
06/01/2021
06/14/2021
11/28/2021
08/18/2022
Locations
Contacts
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
WOODBROTHERSINC@GMAIL.COM  
ACH DEVELOPMENT LLC, Address:3170 NE CARNEGIE DR STE 400  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
BMW ELECTRIC CO, Address:1238 W 31ST, Phone:(816) 289-3474  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $450.00 $450.00 Paid 06/14/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/14/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/14/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/14/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/14/2021
9110078-Valuation Fee New Single Family $1,701.13 $1,701.13 Paid 06/14/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/12/2021 (1:30) 7/12/2021 07/12/2021
Erosion Control Inspection Residential Failed 8/12/2021 08/12/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/12/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Failed 8/12/2021 8/12/2021 08/12/2021
Misc
Corrective Action Required
08/12/2021
-Erosion control shall be in compliance -Provide backfill at several locations to allow inspection of the plumbing
Underslab Plumbing Inspection - Residential Passed 8/17/2021 8/17/2021 08/17/2021
Misc
Resolved
08/17/2021
-Erosion control shall be in compliance -Provide backfill at several locations to allow inspection of the plumbing
Sewer Service Inspection - R Failed 9/8/2021 (2:30) 9/8/2021 09/08/2021
Misc
Corrective Action Required
09/08/2021
-PROVIDE A CLEANOUT AT SEWER CHANGE OF DIRECTION MORE THAN 45 DEG
Water Service Inspection - R Passed 9/20/2021 (1:00) 9/20/2021 09/20/2021
Sewer Service Inspection - R Passed 9/20/2021 9/20/2021 09/20/2021
Misc
Resolved
09/20/2021
-PROVIDE A CLEANOUT AT SEWER CHANGE OF DIRECTION MORE THAN 45 DEG
Electrical Service Inspection Failed 1/19/2022 1/19/2022 01/19/2022
Misc
Corrective Action Required
01/19/2022
-Shall ground to ufer rebar with #4 copper conductor -Use listed rebar grounding clamp. Looks like a water pipe grounding clamp -Complete feeder to sub panel
Gas Service Inspection - Residential Failed 1/19/2022 1/19/2022 01/19/2022
Misc
Corrective Action Required
01/19/2022
-Complete gas piping
All Rough Inspection - Residential Failed 1/19/2022 1/19/2022 01/19/2022
Misc
Corrective Action Required
01/19/2022
-Nail ZIP board to sill plate @ 6” oc -Provide backyard floodlight -Provide a wall receptacle for wall wider than 3 ft when foyer is larger than 60 sq ft -Provide smoke/CO alarm immediately outside master bedroom -Protect water lines in master shower -Vent bath fan in master bathroom -Inside boxes, tie together equipment grounding conductors with listed devices -Secure wiring within 8” of single gang box, not 12” -Floor receptacle box must be listed for installation in floor -Provide wall receptacle spacing per code at rear kitchen exterior wall -Nail corner studs at rear breakfast rm; at 2nd fl bedrooms -Complete electrical above kitchen -Anchor garage PFH walls per code -Frame around garage I beam -Protect wirings within six ft of attic access -Provide wall receptacle spacing per code 2nd fl loft -Provide smoke/CO alarm immediately outside 2nd fl bedroom area -Provide stair illumination per code -Protect wirings running across bottom of joists with running board **OK TO INSULATE
Piers/Caissons Inspection - Residential Passed 1/20/2022 (10:00) 1/20/2022 01/20/2022
All Rough Inspection - Residential Failed 1/25/2022 1/25/2022 01/25/2022
Misc
Corrective Action Required
01/19/2022
-Provide wall receptacle spacing per code at rear kitchen exterior wall **At any point along the wall, there shall be a wall receptacle located within six ft -Anchor garage PFH walls per code **no good -Provide wall receptacle spacing per code 2nd fl loft **At any point along the wall (Note: a guardrail on the perimeter of the loft is considered a wall space), there shall be a wall receptacle located within six ft -Secure and support the hot tub circuit at max 4.5 ft interval
Electrical Service Inspection Failed 1/25/2022 1/25/2022 01/25/2022
Misc
Corrective Action Required
01/19/2022
-Use listed rebar grounding clamp. Looks like a water pipe grounding clamp **Use a listed rebar grounding clamp, like a J-DB Jones rebar clamp. The current acorn clamp is only listed for grounding copper conductor to a grounding rod (copper clad material). Notice this acorn clamp allows the copper GEC to be in direct contact with the iron rebar, which is not allowed because of dissimilar materials.
Electrical Service Inspection Passed 1/27/2022 1/27/2022 01/27/2022
Misc
Resolved
01/27/2022
Gas Service Inspection - Residential Failed 1/27/2022 1/27/2022 01/27/2022
Misc
Corrective Action Required
01/19/2022
-Gas line bond required Pressure test ok
All Rough Inspection - Residential Failed 1/27/2022 1/27/2022 01/27/2022
Misc
Corrective Action Required
01/25/2022
-post site address -seal through floor penetration of ward flex at fireplace -seal bottom and top plate penetrations at AC line kitchen wall -seal bottom plate penetrations at NM master shower -Gas line bond required
All Rough Inspection - Residential Passed 1/28/2022 1/28/2022 01/28/2022
Misc
Resolved
01/28/2022
Gas Service Inspection - Residential Passed 1/28/2022 1/28/2022 01/28/2022
Misc
Resolved
01/28/2022
-Gas line bond required Pressure test ok
Driveway Inspection Partial 3/2/2022 03/02/2022
Misc
Informational
03/02/2022
1-2-22 AN form are in place and aggregate is present and compacted
Driveway Inspection Passed 3/11/2022 3/11/2022 03/16/2022
Misc
Informational
03/02/2022
1-2-22 AN form are in place and aggregate is present and compacted
Misc
Informational
03/16/2022
3-16-22 AN driveway looks good and has expansion joints at curb and right of way. No sidewalk
Erosion Control Inspection Residential Passed 06/07/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/07/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 6/7/2022 6/7/2022 06/07/2022
Misc
Corrective Action Required
06/07/2022
-Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Provide sewer tracer wire port at grade -Complete exterior stair at slide door -Complete guardrail and handrail throughout -Install box extension for switch box at top stair landing; master bedroom -Provide box extension for all electrical boxes recessed more than 1/4” behind non-combustible wall finish: master bathroom shower wall; kitchen backsplash -Provide a wall receptacle at cabinets adjacent to fireplace with countertop. FYI: cabinet with countertop is considered as a wall space where wall receptacle requirement is applied. Receptacles inside the cabinet do not count. NEC 210.52 -Garage door not self-closing -Provide breaker lock for oven, kitchen hood , out-of-sight water heater -Receptacles in unfinished basement shall be gfci-protected -Provide AFCI protection for all outlets required per NEC 210.12. All 15-20 amp outlets required to be afci-protected except: garage, outdoor, bathroom, unfinished basement -Provide gfci protection for clothes washer and dishwasher outlets -Fb floor at master bathroom tub trap -Support expansion tank per manufacturer. See manual -Oven breaker does not have breaker tie -Provide maximum 25 amp breaker for AC units
Occupancy Inspection - Codes Residential Temporary C of O 6/10/2022 6/10/2022 06/10/2022
Misc
Corrective Action Required
06/07/2022
-Final grade, sod, downspout and sump pump extension -Paint exterior gas service piping -Garage door not self-closing -Receptacles in unfinished basement shall be gfci-protected **The sump pump receptacle must be gfci-protected or install a dedicated single plug receptacle -Fb floor penetration at master bathroom tub trap
Occupancy Inspection - Codes Residential Temporary C of O 6/13/2022 6/13/2022 06/13/2022
Misc
Corrective Action Required
06/10/2022
-Final grade, sod, downspout and sump pump extension -Paint exterior gas service piping
Occupancy Inspection - Codes Residential Full C of O 8/18/2022 08/18/2022
Misc
Resolved
08/18/2022
-Final grade, sod, downspout and sump pump extension -Paint exterior gas service piping
Documents & Images
Date Uploaded File Type Document Name
06/01/2021 Application Form APPLICATION
06/01/2021 Application Form excise tax
06/01/2021 Permit Codes Residential Plan Review
06/09/2021 Plot Plan APPROVED PLOT PLAN
06/09/2021 Approved Plans APPROVED PLANS
06/09/2021 Permit Codes Residential Plan Review
06/14/2021 Permit DS Building Permit
06/14/2021 Receipt Receipt for transaction:2021-004410
07/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/17/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/20/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/10/2022 Letter Codes Temporary Certificate of Occupancy
06/13/2022 Letter Codes Temporary Certificate of Occupancy
08/18/2022 Letter Codes Final Certificate of Occupancy
08/18/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home