Permit Application Status

PRRES20212481


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212481
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - UNCOVERED PATIO
05/14/2021
05/17/2021
06/09/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,025.80 $1,025.80 Paid 05/17/2021
Right of Way Permit Fee $80.00 $80.00 Paid 05/17/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/17/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 05/17/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 05/17/2021
Water Meter Fee $455.54 $455.54 Paid 05/17/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/11/2021 (11:30) 6/11/2021 06/11/2021
Underslab Plumbing Inspection - Residential Passed 7/22/2021 7/22/2021 07/22/2021
Sewer Service Inspection - R Passed 8/26/2021 08/26/2021
Water Service Inspection - R Passed 8/27/2021 (9:45) 8/27/2021 08/27/2021
Erosion Control Inspection Residential Failed 8/27/2021 8/27/2021 08/27/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/27/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Partial 9/30/2021 9/30/2021 09/30/2021
Misc
Informational
09/30/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Electrical Service Inspection Passed 1/13/2022 1/13/2022 01/13/2022
Gas Service Inspection - Residential Passed 1/13/2022 1/13/2022 01/13/2022
All Rough Inspection - Residential Failed 1/13/2022 1/13/2022 01/13/2022
Misc
Informational
09/30/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
01/13/2022
-corner stud over notched for electrical, NE and SE corners of garage at dbl car bay -UFER at garage must remain accessible at finish -seal all top plate and bottom plate penetrations, see master vanity, master bed, foyer, unused bore front bedroom, great room -security blocking at rear door -solid shim behind hinges at rear door -Install stud shoes at studs bored for data tube at great room fireplace -seal gas line floor penetration at fireplace -secure gas flex line at fireplace -top plate to top plate connection as required by code front entry wall -fireblock between studs at ceiling box, foyer closet, open to attic space above -solid block at sheathing breaks -H2.5 truss hold downs at all hip trusses -CS-PF bracing at great room exterior wall, tension strap location and length per design -rafter ties at front porch, land rafters to top plate and nail per code, unable to inspect all rafters with cover -address overbored and broken studs at basement bedroom closet -seal top plate penetration for low volt basement bedroom closet -complete DWV waste line above flex room at basement -solid block between joists at cantilevers -fireblock vertical to horizontal at furred down soffit ends -address floor joist bored less than 2” from end of joist for AC line, basement bedroom -fireblock above top plate between foundation wall at basement bedrooms (see above windows) and basement bathroom, seal any gaps around beams and annular spaces around plumbing penetrations -fireblock at top plate with furred strip on studs at basement den wall -Install joist hanger at dbl joist to beam connection 1st floor stair landing, joists not supported 1 1/2” bearing on plates -max 24” oc stud spacing at basement interior non load bearing walls
All Rough Inspection - Residential Failed 1/19/2022 1/19/2022 01/19/2022
Misc
Resolved
01/19/2022
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
01/13/2022
-Install stud shoes at studs bored for data tube at great room fireplace -rafter ties at front porch, land rafters to top plate and nail per code, unable to inspect all rafters with cover -Install joist hanger at dbl joist to beam connection 1st floor stair landing, joists not supported 1 1/2” bearing on plates -max 24” oc stud spacing at basement interior non load bearing walls
All Rough Inspection - Residential Failed 1/25/2022 1/25/2022 01/25/2022
Misc
Informational
01/19/2022
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
01/19/2022
-Install stud shoes at studs bored for data tube at great room fireplace Okay to insulate expect area noted above
All Rough Inspection - Residential Passed 1/27/2022 1/27/2022 01/27/2022
Misc
Resolved
01/27/2022
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Resolved
01/27/2022
-Install stud shoes at studs bored for data tube at great room fireplace Okay to insulate expect area noted above
Driveway Inspection Passed 3/25/2022 3/25/2022 03/25/2022
Misc
Informational
03/25/2022
On Friday, 3-25-2022 a driveway inspection was performed and passed for concrete placement.
Sidewalk Inspection Passed 3/25/2022 3/25/2022 03/25/2022
Misc
Informational
03/25/2022
On Friday, 3-25-2022 a sidewalk inspection was completed and passed inspection for placement of concrete.
Piers/Caissons Inspection - Residential Passed 5/4/2022 05/04/2022
Occupancy Inspection - Codes Residential Failed 5/4/2022 5/4/2022 05/04/2022
Misc
Corrective Action Required
05/04/2022
-complete final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -seal top of meter can,A/c disconnect and all other exterior penetrations. -missing spindles at stairwell guard rail -spark ring at outlet above fire place -missing hing and security screws at back door -complete electrical in master bath spark rings as required -sheet off set screw at water anti syphon device -complete electrical and in basement room near kitchenette -complete electrical at kitchenette area in basement -uncover smoke detectors in basement
Occupancy Inspection - Codes Residential Failed 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/04/2022
-complete final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -seal top of meter can,A/c disconnect and all other exterior penetrations. -security screws at back door hinges and strike plates per city security code
Occupancy Inspection - Codes Residential Temporary C of O 5/12/2022 5/12/2022 05/12/2022
Misc
Corrective Action Required
05/11/2022
TCO Until 6/13/22 -complete final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -seal top of meter can,A/c disconnect and all other exterior penetrations.
Plot Plan Inspection Passed 06/09/2022
Occupancy Inspection - Codes Residential Full C of O 6/9/2022 6/9/2022 06/09/2022
Misc
Resolved
06/09/2022
TCO Until 6/13/22 -complete final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -seal top of meter can,A/c disconnect and all other exterior penetrations.
Documents & Images
Date Uploaded File Type Document Name
05/14/2021 HT #148 - PERMIT APP
05/14/2021 Approved Plans Approved Drawings
05/14/2021 Approved Plans Approved Truss Layout
05/14/2021 Approved Plans Approved Truss Package
05/14/2021 Plot Plan Approved Plot Plan
05/14/2021 Permit Codes Residential Plan Review
05/17/2021 Permit DS Building Permit
05/17/2021 Receipt Receipt for transaction:2021-003056
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/18/2022 148 Hawthorne Ridge Field Issue Letter
01/19/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/26/2022 148 Hawthorne Ridge Over bored stud letter
01/27/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter Codes Temporary Certificate of Occupancy
06/09/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter Field Certificate of Occupancy
06/09/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home