Permit Application Status

PRRES20212068


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212068
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED/UNCOVERED DECK
04/28/2021
05/03/2021
10/26/2021
09/23/2022
Locations
Contacts
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
CARDINAL CREST HOMES, Address:1539 SWIFT AVE, Phone:(816) 499-3156  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
JOE KILOWATT INC, Address:6506 ROYAL, Phone:(816) 792-4888  
HAMPTON PLUMBING INC, Address:P O BOX 552, Phone:(816) 628-5069  
JAMES@CARDINALCRESTHOMES.COM  
  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/04/2021 05/03/2021
Kim Brennan
Property boundary
Corrective Action Required
04/30/2021

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. The distance of 120.66 should be 120.65 as shown on the recorded plat
Deck location
Corrective Action Required
04/30/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Lot elevations
Corrective Action Required
04/30/2021

Existing and finish elevations at all property corners must be provided on the plot plan. The dimension in the rear corner is cut off
Basement elevation
Corrective Action Required
04/30/2021

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.)
Residential Plan Review Approved 05/04/2021 04/30/2021
Kim Brennan
Misc
Corrective Action Required
04/30/2021

Please dimensionally lpcate pier pads in the garage
30 Identify type of protection used in unfinished areas under
Corrective Action Required
04/30/2021

Identify type of protection used in unfinished areas under floor trusses. (IRC Section R501.3)
Plot Plan Review Rejected 04/30/2021 04/29/2021
Kim Brennan
Property boundary
Corrective Action Required
04/29/2021

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. The distance of 120.66 should be 120.65 as shown on the recorded plat
Deck location
Corrective Action Required
04/29/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Lot elevations
Corrective Action Required
04/29/2021

Existing and finish elevations at all property corners must be provided on the plot plan. The dimension in the rear corner is cut off
Basement elevation
Corrective Action Required
04/29/2021

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.)
Residential Plan Review Rejected 04/30/2021 04/29/2021
Kim Brennan
Misc
Corrective Action Required
04/29/2021

Please dimensionally lpcate pier pads in the garage
30 Identify type of protection used in unfinished areas under
Corrective Action Required
04/29/2021

Identify type of protection used in unfinished areas under floor trusses. (IRC Section R501.3)
Planning Review (RES) Approved 04/30/2021 04/28/2021
Shannon McGuire
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,121.30 $1,121.30 Paid 05/03/2021
$0.00
Right of Way Permit Fee $80.00 $80.00 Paid 05/03/2021
8331507-Sewer Connection Fee $450.00 $450.00 Paid 05/03/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 05/03/2021
Water Meter Fee $455.54 $455.54 Paid 05/03/2021
Escrow Deposit $1,077.12 $1,077.12 Paid 05/03/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 07/27/2022
Not Ready Inspection Fee $50.00 $50.00 Paid 07/27/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 07/29/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 09/16/2022
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 8/18/2021 8/18/2021 08/18/2021
Misc
Corrective Action Required
08/18/2021
-PROVIDE FULL GRAVEL SUPPORT FOR PLUMBING
Underslab Plumbing Inspection - Residential Not Ready 8/27/2021 8/27/2021 08/27/2021
Misc
Corrective Action Required
08/18/2021
-PROVIDE FULL GRAVEL SUPPORT FOR PLUMBING
Miscellaneous Correction
Corrective Action Required
08/27/2021
PROVIDE GRAVEL BED FOR UNDERSLAB PLUMBING 2018 IRC P2604.1
Underslab Plumbing Inspection - Residential Passed 8/30/2021 8/30/2021 08/30/2021
Misc
Resolved
08/30/2021
-PROVIDE FULL GRAVEL SUPPORT FOR PLUMBING
Miscellaneous Correction
Resolved
08/30/2021
PROVIDE GRAVEL BED FOR UNDERSLAB PLUMBING 2018 IRC P2604.1
Gas Service Inspection - Residential Passed 1/27/2022 1/27/2022 01/27/2022
Sewer Service Inspection - R Passed 1/27/2022 (1:00) 1/27/2022 01/27/2022
Water Service Inspection - R Passed 1/28/2022 (1:00) 1/28/2022 01/28/2022
All Rough Inspection - Residential Not Ready 3/7/2022 3/7/2022 03/07/2022
Miscellaneous Correction
Corrective Action Required
03/07/2022
NOT READY no city stamped plans No city stamped truss package No fire blocking No inspection done
All Rough Inspection - Residential Failed 3/14/2022 3/14/2022 03/14/2022
Miscellaneous Correction
Corrective Action Required
03/07/2022
REWORKING TRUSS AT VAULTED FRONT No inspection done
Erosion Control Inspection Residential Failed 3/14/2022 03/14/2022
Misc
Corrective Action Required
03/14/2022
Repair silt fence
All Rough Inspection - Residential Failed 3/17/2022 3/17/2022 03/17/2022
Miscellaneous Correction
Corrective Action Required
03/14/2022
- front porch not inspected, remove sheeting enough to see framing - Patio roof not inspected, remove sheeting to provide access to framing - Provide anchor bolts PFH portal frame and 2”x2”x3/16” washer - Complete nailing pattern exterior for PFG garage door per plan - Lateral bracing loose at trusses in garage - Provide roof boots - Nail all exterior corners through out to code - Fire block top of chase laundry vent into garage - Add stud shoe laundry DWV load Bering wall - Replace straps at top plate laundry DWV to proper size and attachment - Strap all DWV vertical under 2” diameter - Provide Boca plate at top plate, DWV bedroom 2 closet - No jack studs bedroom 2 entry - Boca plates on DWV master bedroom entry - Fire block penetrations floor hall to master - Fire block top plate penetration master bedroom at stairs - Provide gravity angle for drainage in attic space for all DWV - Provide stud shoes kitchen exterior wall DWV - Boca plate top plate kitchen DWV - Provide proper ductwork for cooking vent hood - Provide missing truss hangers at dining room - Provide missing truss screws on girders in great room - Shim studs supporting truss great room at hall, exterior wall - Look at header hall entry - Provide Egress windows basement - Boca plate floor basement bedroom 3 - Protect DWV at top plate in bedroom 4 basement
All Rough Inspection - Residential Failed 3/25/2022 3/25/2022 03/25/2022
Miscellaneous Correction
Corrective Action Required
03/17/2022
- front porch not inspected, remove sheeting enough to see framing - Patio roof not inspected, remove sheeting to provide access to framing - Provide anchor bolts PFH portal frame and 2”x2”x3/16” washer - Nail all exterior corners through out to code - Replace straps at top plate laundry DWV to Boca plate - Strap all DWV vertical under 2” diameter - Provide Boca plate at top plate, DWV bedroom 2 closet -Boca plates on DWV master bedroom entry - Fire block penetrations floor hall to master - Fire block top plate penetration master bedroom at stairs - Shim studs supporting truss great room at hall, exterior wall
Erosion Control Inspection Residential Failed 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/14/2022
Repair silt fence No further inspections until corrections are made
All Rough Inspection - Residential Failed 3/30/2022 3/30/2022 03/30/2022
Miscellaneous Correction
Corrective Action Required
03/25/2022
- Fire block top plate penetration master bedroom at stairs - Shim studs supporting truss great room at hall, exterior wall Remove lumber and debris off of silt fence at front of lot. Repair silt fence no further inspection until corrections are made
Erosion Control Inspection Residential Failed 3/30/2022 03/30/2022
Misc
Corrective Action Required
03/25/2022
Remove lumber and debris on silt fence at front of lot Repair silt fence No further inspections until corrections are made
All Rough Inspection - Residential Passed 4/5/2022 4/5/2022 04/05/2022
Miscellaneous Correction
Resolved
04/05/2022
- Fire block top plate penetration master bedroom at stairs - Shim studs supporting truss great room at hall, exterior wall Remove lumber and debris off of silt fence at front of lot. Repair silt fence no further inspection until corrections are made
Sidewalk Inspection Partial 5/4/2022 5/4/2022 05/10/2022
Misc
Informational
05/10/2022
Sidewalk was framed up with aggregate in and compacted 5/4/22. Checked again on 5/6/22 after rains. 5/6/22 ES
Sidewalk Inspection Partial 5/20/2022 5/20/2022 05/20/2022
Misc
Informational
05/10/2022
Sidewalk was framed up with aggregate in and compacted 5/4/22. Checked again on 5/6/22 after rains. 5/6/22 ES
Misc
Informational
05/20/2022
Sidewalk meets LS and ADA spec. 5/20/22 ES
Erosion Control Inspection Residential Failed 4/5/2022 05/24/2022
Misc
Resolved
04/05/2022
Remove lumber and debris on silt fence at front of lot Repair silt fence No further inspections until corrections are made
Misc
Corrective Action Required
05/24/2022
Silt fence needs repaired around property, but especially in back where draining into alley way. 5/24/22 ES
Erosion Control Inspection Residential Failed 05/24/2022
Misc
Corrective Action Required
05/24/2022
Silt fence needs repaired around property, but especially in back where draining into alley way. 5/24/22 ES
Footing Inspection - Residential Passed 06/29/2022
Misc
Informational
06/29/2022
THIRD PARTY INSPECTION
Erosion Control Inspection Residential Failed 6/29/2022 06/29/2022
Misc
Corrective Action Required
05/24/2022
EROSION CONTROL REQUIRED AT FRONT OF LOT
Electrical Service Inspection Passed 6/29/2022 6/29/2022 06/29/2022
Occupancy Inspection - Codes Residential Failed 7/28/2022 7/28/2022 07/28/2022
Misc
Corrective Action Required
07/28/2022
-maintain erosion control on lot until sod is placed -final sidewalk and driveway inspection required, contact development services to schedule -provide address numbers house -handrail required at exterior front stairs and side patio -provide as graded plot plan for review and approval -final grade and sod -gutters and downspouts required -splash blocks -install all exterior light fixtures -install exterior outlet front porch -install final front door, deadbolt required per ordinance -install light fixture great room -install master bath vanity light -hammer arrestors at laundry spigots -GFCI protection garage receptacles -security screws at exterior door, (2) 3” screws at each hinge and strike plate -install switch at basement hall -install basement bed egress well ladders -install latch at basement bed window -install smoke at basement mech room -complete mineral wool install at I joists at unfinished basement mech room -shear off head on anti siphon main water line basement -mark all dedicated receptacles at garage and unfinished basement as not GFCI protected
Erosion Control Inspection Residential Failed 7/28/2022 7/28/2022 07/28/2022
Misc
Corrective Action Required
06/29/2022
-maintain erosion control on lot until sod is placed
Occupancy Inspection - Codes Residential Ready for Temp CO 7/29/2022 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/28/2022
-maintain erosion control on lot until sod is placed -final sidewalk and driveway inspection required, contact development services to schedule -handrail required at exterior front stairs and side patio -provide as graded plot plan for review and approval -final grade and sod -gutters and downspouts required -splash blocks TCO expiration 8/28/22
Occupancy Inspection - Codes Residential Temporary C of O 07/29/2022
Misc
Corrective Action Required
07/29/2022
-maintain erosion control on lot until sod is placed -final sidewalk and driveway inspection required, contact development services to schedule -handrail required at exterior front stairs and side patio -provide as graded plot plan for review and approval -final grade and sod -gutters and downspouts required -splash blocks TCO expiration 8/28/22
Driveway Inspection Passed 9/6/2022 9/6/2022 09/07/2022
Misc
Informational
09/07/2022
Driveway is off of alley way, no inspection required. 9/6/22 ES
Sidewalk Inspection Passed 9/6/2022 9/6/2022 09/07/2022
Misc
Informational
05/20/2022
Sidewalk was framed up with aggregate in and compacted 5/4/22. Checked again on 5/6/22 after rains. 5/6/22 ES
Misc
Informational
05/20/2022
Sidewalk meets LS and ADA spec. 5/20/22 ES
Erosion Control Inspection Residential Passed 9/20/2022 09/16/2022
Misc
Resolved
09/16/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 9/16/2022 9/16/2022 09/16/2022
Misc
Corrective Action Required
07/29/2022
-provide as graded plot plan for review and approval -as graded plot plan not approved Shawn Hoffman 09/16/2022 11:02 AM -pay fee on TCO extension - upload TCO extension form
Occupancy Inspection - Codes Residential Temporary C of O 09/20/2022
Misc
Corrective Action Required
09/16/2022
-provide as graded plot plan for review and approval -as graded plot plan not approved Shawn Hoffman 09/16/2022 11:02 AM
Plot Plan Inspection Passed 9/23/2022 09/23/2022
Occupancy Inspection - Codes Residential Full C of O 09/23/2022
Misc
Resolved
09/23/2022
Documents & Images
Date Uploaded File Type Document Name
04/28/2021 Application Form Permit Application
04/28/2021 Application Form License Tax Form
04/29/2021 Letter Codes Residential Plan Review
04/30/2021 Approved Plans Approved Drawings
05/03/2021 Plot Plan Approved Plot Plan
05/03/2021 Receipt Receipt for transaction:2021-002415
06/30/2021 Approved Plans Approved I-Joist Layout
06/30/2021 Approved Plans Approved Truss Layout
06/30/2021 Approved Plans Approved Revised Drawings
08/02/2021 Pergola Park, Lot 105 - footing
08/02/2021 Pergola Park, Lot 105 - wall
08/18/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
03/07/2022 Letter INSPECTION SUMMARY
03/14/2022 Letter INSPECTION SUMMARY
03/14/2022 Letter INSPECTION SUMMARY
03/15/2022 P210169 - Sealed Scab and Repair Truss Drawings
03/15/2022 ROOF TPD 18x24
03/15/2022 P210169 - G5 Sealed Truss Drawing
03/17/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
07/27/2022 Receipt Receipt for transaction:2022-006151
07/28/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
07/29/2022 Receipt Receipt for transaction:2022-006238
07/29/2022 Letter Codes Temporary Certificate of Occupancy
09/07/2022 Letter INSPECTION SUMMARY
09/07/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
09/16/2022 Receipt Receipt for transaction:2022-007600
09/20/2022 Activity Document TCO Extension Form
09/20/2022 Letter Codes Temporary Certificate of Occupancy
09/22/2022 Plot Plan Approved As Graded Plot Plan
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter Field Certificate of Occupancy
09/23/2022 Letter Codes Final Certificate of Occupancy
02/01/2023 Receipt Receipt for transaction: 2021-002415
12/19/2023 Permit DS Building Permit11
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home