PRRES20211433
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES -
03/30/2021
03/31/2021
01/18/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/01/2021 03/31/2021
Brandon Kalwei
Residential Plan Review Approved 04/01/2021 03/30/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $961.05 $961.05 Paid 03/31/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 03/31/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/31/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/31/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/31/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/31/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/04/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/04/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 01/04/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/10/2021 05/10/2021
Misc
Informational
05/10/2021
3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED CENTER OF EAST ( REAR ) GARAGE FOUNDATION WALL
Underslab Plumbing Inspection - Residential Passed 6/2/2021 6/2/2021 06/02/2021
All Rough Inspection - Residential Not Ready 8/4/2021 8/4/2021 08/04/2021
Misc
Corrective Action Required
08/04/2021
No city approved plans on site Garage anchor bolts shall Land in middle 1/3 of width of plate Covered patio provide hangers & H2.5a per plan Front porch trusses not set at this time
Sewer Service Inspection - R Passed 9/27/2021 (1:00) 9/27/2021 09/27/2021
Water Service Inspection - R Passed 9/28/2021 (11:30) 9/28/2021 09/28/2021
All Rough Inspection - Residential Failed 9/28/2021 9/28/2021 09/28/2021
Misc
Resolved
09/28/2021
PORTAL FRAME, PORCH, PATIO OK TO COVER ONLY THE ABOVE INSPECTED
Misc
Corrective Action Required
09/28/2021
-Erosion control required before any further inspections -Strap top plates above 2 car door not overlapping 2’ -Nail all corners and intersecting walls per code -Provide attic access per code -Exterior walls not connected at top plates at garage/entry and entry/ bed 2 -Block and nail sheathing break at pantry window -All wall outlets at garage to be 20 amp -Bocca plate at bottom plate laundry room -Missing H2.5s at dining room and bed 1 -Seal gaps in fireblocking at fireplace -Solid block and nail sheathing break at bed 2 -Complete CS-PF at dining -Provide missing truss hangers at J5, T9 T10, T11 at master -HJC 26 Truss hangers at covered patio, bed 2, bed 1 -Truss bracing H19, H2 -Solid blocking between joists 48” oc and extend one bay past each side at island -Have engineer address foundation wall crack from beam pocket slab at north wall-daylight visible through crack -Fireblock tub trap from below bath 2 -Address improperly flashed egress window-no flashing tape at bottom corner -Gas and electrical ok-schedule with re inspection
Electrical Service Inspection Passed 10/6/2021 10/06/2021
Gas Service Inspection - Residential Passed 10/6/2021 10/06/2021
All Rough Inspection - Residential Not Ready 10/6/2021 10/6/2021 10/06/2021
Misc
Corrective Action Required
09/28/2021
-Nail all corners and intersecting walls per code ( Great room outside bed #1) -Exterior walls not connected at top plates at garage/entry and entry/ bed 2 ( solid block & nail per code ) -Solid block and nail sheathing break at bed 2 ( front corner at porch ) -Complete CS-PF at dining ( 2018 IRC FIGURE R602.10.6.4 Page # 209) -Provide missing truss hangers at J5, ( bed # 1 closet ) T11 at master -HJC 26 Truss hangers at bed 2, / FRONT PORCH) -Solid blocking between joists 48” oc and extend one bay past each side at island ( ISLAND BETWEEN BEAM & STAIRWAY BLOCKING IS REAR FOUNDATION WALL TO BEAM )
All Rough Inspection - Residential Failed 10/12/2021 10/12/2021 10/12/2021
Misc
Corrective Action Required
10/06/2021
See note on front sidelights. -Exterior walls not connected at top plates at garage/entry and entry/ bed 2 ( solid block & nail per code ) -Have engineer address foundation wall crack from beam pocket slab at north wall-daylight visible through crack ( NO ENGINEER LETTER UPLOADED TO PERMIT )
All Rough Inspection - Residential Passed 10/13/2021 10/13/2021 10/13/2021
Misc
Resolved
10/13/2021
See note on front sidelights. -Exterior walls not connected at top plates at garage/entry and entry/ bed 2 ( solid block & nail per code ) -Have engineer address foundation wall crack from beam pocket slab at north wall-daylight visible through crack ( NO ENGINEER LETTER UPLOADED TO PERMIT )
Driveway Inspection Partial 10/14/2021 10/14/2021 10/14/2021
Misc
Informational
10/14/2021
10-14-21 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 10/22/2021 10/22/2021 10/18/2021
Misc
Informational
10/14/2021
10-14-21 AN forms are in place and aggregate is present and compacted
Misc
Informational
10/18/2021
10-18-21 AN driveway looks good and has expansion joints at curb and right of way. No sidewalk
Plot Plan Inspection Passed 1/4/2022 01/04/2022
Occupancy Inspection - Codes Residential Failed 1/4/2022 1/4/2022 01/04/2022
Miscellaneous Correction
Corrective Action Required
01/04/2022
Pay not ready fees No pier inspection 3rd party footing ? Submit back flow certification lawn irrigation permit Complete downspout front stoop Garage door shall be self closing @ self latching Provide weatherstripping self closing door Handrail garage shall support 200 lbs of force Sump shall discharge 36" from foundation wall Splash block shall discharge water 36" from foundation
Occupancy Inspection - Codes Residential Full C of O 1/18/2022 1/18/2022 01/18/2022
Miscellaneous Correction
Informational
01/18/2022
Submit back flow certification lawn irrigation permit
Documents & Images
Date Uploaded File Type Document Name
03/30/2021 Application Form APPLICATION
03/30/2021 LOT 63 FINAL
03/30/2021 W2 #63 - Bradford - Mediterranean - Sheets- signed
03/30/2021 63 WOODSIDE RIDGE ROOF LAYOUT
03/30/2021 I44987087_W2-63
03/30/2021 Approved Plans APPROVED TRUSS DRAWINGS
03/30/2021 Approved Plans APPROVED TRUSS LAYOUT
03/30/2021 Plot Plan APPROVED PLOT PLAN
03/31/2021 Receipt Receipt for transaction:2021-001644
03/31/2021 W2 #63 - REVISED Bradford - Mediterranean - Sheets- signed
03/31/2021 Approved Plans APPROVED PLANS
03/31/2021 Letter DS Building Permit
05/10/2021 Lot 63 Woodside Ridge Footing inspection
05/10/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/07/2021 107 NW Joshua Dr - Foundation Inspection
10/12/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/18/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/04/2022 Receipt Receipt for transaction:2022-000058
01/13/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter Codes Final Certificate of Occupancy
01/18/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home