Permit Application Status

PRRES20211033


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211033
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK - ROOF TRUSSES STOP WORK ORDER generated on 04/16/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 04/19/2021 12:00 AM by username 'Patrick Schonfeldt'.
03/09/2021
03/12/2021
09/08/2021
01/18/2022
Locations
Contacts
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/16/2021 03/12/2021
Brandon Kalwei
Residential Plan Review Approved 03/16/2021 03/12/2021
Brandon Kalwei
Plot Plan Review Approved 03/11/2021 03/09/2021
Brandon Kalwei
Residential Plan Review Approved 03/11/2021 03/09/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,277.87 $1,277.87 Paid 03/12/2021
8331504-EFHB Middle Big Creek, Full $569.16 $569.16 Paid 03/12/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 03/12/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/12/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/12/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/12/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/12/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 01/11/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed - Stop Work 4/16/2021 4/16/2021 04/16/2021
Misc
Corrective Action Required
04/16/2021
-FOOTING POURED WITHOUT INSPECTION, SUBMIT ENGINEER REPORT, REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 2 DAYS OF INSPECITON
Footing Inspection - Residential Passed 4/19/2021 04/19/2021
Misc
Resolved
04/19/2021
Underslab Plumbing Inspection - Residential Passed 4/28/2021 4/28/2021 04/28/2021
Sewer Service Inspection - R Passed 7/12/2021 (11:15) 7/12/2021 07/12/2021
Water Service Inspection - R Partial 7/12/2021 7/12/2021 07/12/2021
Misc
Informational
07/12/2021
PARTIAL INSPECTION ON PEX TO HOUSE ENTRANCE
Water Service Inspection - R Passed 7/13/2021 (8:45) 7/13/2021 07/13/2021
Misc
Resolved
07/13/2021
Erosion Control Inspection Residential Failed 7/13/2021 7/13/2021 07/13/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/13/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Partial 7/27/2021 7/27/2021 07/27/2021
Misc
Corrective Action Required
07/27/2021
-GARAGE PORTAL EXTERIOR OK
All Rough Inspection - Residential Failed 9/8/2021 9/8/2021 09/08/2021
Misc
Informational
09/08/2021
-GARAGE PORTAL EXTERIOR OK
Misc
Corrective Action Required
09/08/2021
-Complete all furred downs and chases at garage wall -Anchor bolts required within 12” of plate breaks at garage and basement -Address floor joist at garage bored for DWV less than 2” from top end of joist- repl or submit engineer letter -Add protection plate at pex top plate kitchen fridge wall, less than 1 1/4” from end of plate -add Stud shoe at kitchen exterior wall bored for DWV -seal all top and bottom plate penetrations - kitchen -seal floor penetration at gas line fireplace -Address over bored dbl 2x10 joist for DWV at 1st floor bath, repl or submit engineer letter -All truss hangers per plans -Remove cover at front porch to allow for inspection of truss H2.5 clips -Attic access at garage and 2nd floor per plans -LIB bracing all locations per plans -Header and add joist hanger to sgl joist at HVAC box out in pantry, floor joist supported currently by non load bearing wall -add snow blocking, master closet, master bath, south bedroom 2nd floor -strap plates- Dbl top plate requires 24” offset between plate breaks- see 2nd floor bed#4 -(4) 2X stud packs at all girder truss bearing ends per plans -Anchor all SCH 40 columns in basement -security blocking basement walkout -Address floor joist cut for DWV north side basement -Address floor joists with bores for NM and SER cable less than 2” apart- see basement north wall above main and sub service panels, sub panel SER cable bored less than 2” from end of joist -repl or submit engineer letter -(2) 2x6 Jack studs at basement window header north side per plans -(3) 2x10 header at basement walkout per plans -(3) 2X4 pack at pier location “A” basement stair wall per plans -Tighten panel bonding screw at service panel -Identify GEC at service panel -Tighten clamps at service panel, SER cable -provide (3) studs, bottom plate, anchor bolts per code at basement East and west corners -Nail exterior sheathing per plans
All Rough Inspection - Residential Failed 9/16/2021 9/16/2021 09/16/2021
Misc
Informational
09/08/2021
-GARAGE PORTAL EXTERIOR OK
Misc
Corrective Action Required
09/08/2021
--Fireblock vertical to horizontal around DWV at garage furred down -Address floor joist at garage bored for DWV less than 2” from top end of joist- repair per submitted engineer letter -Address over bored dbl 2x10 joist for DWV at 1st floor bath, repair per submitted engineer letter -All truss hangers per plans - see covered deck -Attic access at 2nd floor per plans -strap plates - Dbl top plate requires 24” offset between plate breaks- see 2nd floor bed#4 -(4) 2X stud packs at all girder truss bearing ends per plans -Nail exterior sheathing per plans
All Rough Inspection - Residential Failed 9/21/2021 9/21/2021 09/21/2021
Misc
Informational
09/16/2021
-GARAGE PORTAL EXTERIOR OK
Misc
Corrective Action Required
09/16/2021
-Address floor joist at garage bored for DWV less than 2” from top end of joist- repair per submitted engineer letter -Address over bored dbl 2x10 joist for DWV at 1st floor bath, repair per submitted engineer letter - Strap plates - Dbl top plate requires 24” offset between plate breaks- see 2nd floor bed#4 -(4) 2X stud packs at all girder truss bearing ends per plans -see bedroom #4
Electrical Service Inspection Passed 9/27/2021 9/27/2021 09/27/2021
Gas Service Inspection - Residential Failed 9/27/2021 9/27/2021 09/27/2021
Misc
Corrective Action Required
09/27/2021
GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Passed 9/27/2021 9/27/2021 09/27/2021
Misc
Resolved
09/27/2021
-GARAGE PORTAL EXTERIOR OK
Misc
Resolved
09/27/2021
-Address floor joist at garage bored for DWV less than 2” from top end of joist- repair per submitted engineer letter -Address over bored dbl 2x10 joist for DWV at 1st floor bath, repair per submitted engineer letter - Strap plates - Dbl top plate requires 24” offset between plate breaks- see 2nd floor bed#4 -(4) 2X stud packs at all girder truss bearing ends per plans -see bedroom #4
Gas Service Inspection - Residential Passed 9/29/2021 9/29/2021 09/29/2021
Misc
Resolved
09/29/2021
Driveway Inspection Passed 10/19/2021 10/19/2021 10/19/2021
Misc
Informational
10/19/2021
On 10/19/2021 I performed a driveway inspection and passed the subgrade to pour concrete
Piers/Caissons Inspection - Residential Passed 12/9/2021 12/09/2021
Misc
Informational
12/09/2021
ADDRESSED IN 3RD PARTY FOOTING INSPECTION REPORT.
Occupancy Inspection - Codes Residential Failed 12/9/2021 12/9/2021 12/09/2021
Misc
Corrective Action Required
12/09/2021
-final grade and sod -check water meter and siding to grade spacing at time of final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -seal top of A/c disconnect -Provide guard rail at front stoop where more than 30”, 36” out -attic access cover for 2nd story attic access -security screws at basement back door
Occupancy Inspection - Codes Residential Failed 12/13/2021 12/13/2021 12/13/2021
Misc
Corrective Action Required
12/09/2021
-final grade and sod -check water meter and siding to grade spacing at time of final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -seal top of A/c disconnect -Provide guard rail at front stoop where more than 30”, 36” out -security screws at basement back door
Occupancy Inspection - Codes Residential Temporary C of O 12/14/2021 12/14/2021 12/14/2021
Misc
Corrective Action Required
12/13/2021
TCO UNTIL 12/28/22 -final grade and sod -check water meter and siding to grade spacing at time of final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -seal top of A/c disconnect -Provide guard rail at front stoop where more than 30”, 36” out
Occupancy Inspection - Codes Residential Failed 12/22/2021 12/22/2021 12/22/2021
Misc
Corrective Action Required
12/14/2021
TCO UNTIL 12/28/22 Provide 6” clearance from siding and grade. At rear of house(see attached photo) Pay all fees
Plot Plan Inspection Passed 1/6/2022 1/6/2022 01/06/2022
Erosion Control Inspection Residential Passed 1/6/2022 1/6/2022 01/06/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/06/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 1/6/2022 1/6/2022 01/06/2022
Misc
Corrective Action Required
12/22/2021
-RESOLVE OUTSTANDING INSPECTION FEE BEFORE FINAL C OF O -OBTAIN LAWN IRRIGATION SYSTEM PERMIT
Occupancy Inspection - Codes Residential Full C of O 1/18/2022 1/18/2022 01/18/2022
Misc
Resolved
01/18/2022
-RESOLVE OUTSTANDING INSPECTION FEE BEFORE FINAL C OF O -OBTAIN LAWN IRRIGATION SYSTEM PERMIT
Documents & Images
Date Uploaded File Type Document Name
03/09/2021 Application Form APPLICATION
03/09/2021 102 MANOR AT STONEY CREEK TRUSS LAYOUT
03/09/2021 210303
03/09/2021 LOT 102 FINAL
03/09/2021 MN #102 - Riverside - Modern Farmhouse - Sheets- signed
03/09/2021 Approved Plans APPROVED PLANS
03/09/2021 Approved Plans APPROVED TRUSS DRAWINGS
03/09/2021 Approved Plans APPROVED TRUSS LAYOUT
03/09/2021 Letter Codes Residential Plan Review
03/09/2021 Plot Plan APPROVED PLOT PLAN
03/12/2021 Receipt Receipt for transaction:2021-001236
03/12/2021 Letter DS Building Permit
04/16/2021 Letter Stop Work Order
04/16/2021 Lot 102 Stoney Creek Footing Inspection
04/16/2021 Lot 102 Manor at Stoney Creek Wall
04/19/2021 Letter INSPECTION SUMMARY
04/28/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/13/2021 Letter INSPECTION SUMMARY
07/13/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter INSPECTION SUMMARY
09/15/2021 102 Manor at Stoney Creek holes in floor joists letter
09/16/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/23/2021 MN102 inspection items final letter
09/27/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/29/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter Codes Temporary Certificate of Occupancy
12/22/2021 CD556E27-05C2-460D-9781-1DA0745E0865.jpeg
12/22/2021 Letter INSPECTION SUMMARY
01/06/2022 Letter INSPECTION SUMMARY
01/06/2022 Letter INSPECTION SUMMARY
01/06/2022 Letter INSPECTION SUMMARY
01/11/2022 Receipt Receipt for transaction:2022-000199
01/18/2022 Letter Field Certificate of Occupancy
01/18/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home