Permit Application Status

PRRES20210901


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210901
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED PATIO
03/02/2021
03/04/2021
01/21/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/05/2021 03/03/2021
Brandon Kalwei
As-graded plot plan
Corrective Action Required
03/03/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 03/05/2021 03/03/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $965.24 $965.24 Paid 03/04/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 03/04/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/04/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/04/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/04/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/04/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/18/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 01/18/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/28/2021 (1:30) 4/28/2021 04/28/2021
Underslab Plumbing Inspection - Residential Passed 5/14/2021 5/14/2021 05/14/2021
Sewer Service Inspection - R Passed 8/4/2021 (11:15) 8/4/2021 08/04/2021
Water Service Inspection - R Passed 8/5/2021 (10:30) 8/5/2021 08/05/2021
All Rough Inspection - Residential Failed 7/12/2021 7/12/2021 08/05/2021
Miscellaneous Correction
Corrective Action Required
07/12/2021
GARAGE PORTAL FRAME ONLY Nail sheathing per code no staples Fasten top plate to header with two rows 16D sinkers 3" OC Provide header to jack stud straps per plan Nail hold downs Spliced edges in sheathing shall occur over and be nailed to common blocking within middle 24" of wall mud height one row of 3" OC nailing is required in each panel edge Per plan details 12 sheet S2.0
Miscellaneous Correction
Corrective Action Required
08/05/2021
: Garage portal frame, Ft porch & patio ONLY : NO PLANS ON SITE PFH portal frame Nail sheathing per code ( no staples) Nail top plate to header w/ 16d sinkers 3" OC Patio covered unable to see trusses Front porch covered unable to see trusses
All Rough Inspection - Residential Not Ready 8/5/2021 8/5/2021 08/05/2021
Misc
Corrective Action Required
08/04/2021
GARAGE PORTAL FRAME ONLY Nail sheathing per code no staples Fasten top plate to header with two rows 16D sinkers 3" OC Provide header to jack stud straps per plan Nail hold downs Spliced edges in sheathing shall occur over and be nailed to common blocking within middle 24" of wall mud height one row of 3" OC nailing is required in each panel edge Per plan details 12 sheet S2.0
Miscellaneous Correction
Corrective Action Required
08/05/2021
: Garage portal frame, Ft porch & patio ONLY : NO PLANS ON SITE PFH portal frame Nail sheathing per code ( no staples) Nail top plate to header w/ 16d sinkers 3" OC Patio covered unable to see trusses Front porch covered unable to see trusses
All Rough Inspection - Residential Failed 9/9/2021 9/9/2021 09/09/2021
Miscellaneous Correction
Resolved
09/09/2021
GARAGE PORTAL FRAME ONLY Nail sheathing per code no staples Fasten top plate to header with two rows 16D sinkers 3" OC Provide header to jack stud straps per plan Nail hold downs Spliced edges in sheathing shall occur over and be nailed to common blocking within middle 24" of wall mud height one row of 3" OC nailing is required in each panel edge Per plan details 12 sheet S2.0
Miscellaneous Correction
Corrective Action Required
08/05/2021
-Restore erosion control at perimeter before any further inspections -Uncover front porch framing and back porch trusses per previous failed inspections -Complete electrical at garage exterior -Anchor bolts to be in middle third of plate in garage -Seal plate penetrations in garage -Re install and nail blocking at pfh panel seams-reroute electrical or move seam -Tighten anchor bolts garage -Nail corners and intersecting walls per code -Fireblock soffit line in garage -Install truss hanger in garage J21 -Provide (4) nails each side of structural straps at load bearing walls -Seal gaps in fireblocking at fireplace -Seal plate penetrations in master bed -Seal through floor penetration at fireplace -Provide (4) studs at all girder truss bearing locations -Anchor columns in basement -Identify white insulated conductors used as current carrying conductors at both points of termination -Seal gap at ufer pocket to garage -Provide joist hangers at header and joist cut above furnace -Solid block joists 48” oc and extend one bay each way at island -Seal exterior penetration in joist above electrical panel -Nail exterior sheathing 6” oc at seams and 12” oc in field
All Rough Inspection - Residential Failed 9/20/2021 9/20/2021 09/20/2021
Miscellaneous Correction
Corrective Action Required
09/20/2021
-Solid block joists 48” oc and extend one bay each way at island ( not done) -Nail exterior sheathing 6” oc at seams and 12” oc in field
Electrical Service Inspection Passed 9/21/2021 9/21/2021 09/20/2021
Gas Service Inspection - Residential Passed 9/21/2021 9/21/2021 09/20/2021
All Rough Inspection - Residential Passed 9/22/2021 9/22/2021 09/22/2021
Miscellaneous Correction
Resolved
09/22/2021
Driveway Inspection Partial 10/4/2021 10/04/2021
Misc
Informational
10/04/2021
Forms are in place and aggregate is present and compacted. No sidewalk
Driveway Inspection Passed 10/8/2021 10/8/2021 10/08/2021
Misc
Informational
10/08/2021
Forms are in place and aggregate is present and compacted
Misc
Informational
10/08/2021
Driveway looks good and has expansion joints at curb and right of way no sidewalk 10-8-21 AN
Occupancy Inspection - Codes Residential Failed 11/18/2021 11/18/2021 11/18/2021
Miscellaneous Correction
Corrective Action Required
11/18/2021
- obtain an back flow certification - address final grading & sod - Address water meter height - provide splash blocks - min 36” away from foundation for sump discharge - seal top of meter can & exterior lights - provide steps for patio - provide anti tip device for stove - need lock & secondary lock for sliding door - provide back flow device at main - address clearance at water heater, bvent and gas line
Occupancy Inspection - Codes Residential Temporary C of O 1/18/2022 1/18/2022 01/18/2022
Miscellaneous Correction
Resolved
01/21/2022
Plot Plan Inspection Passed 1/21/2022 01/21/2022
Occupancy Inspection - Codes Residential Full C of O 1/21/2022 01/21/2022
Miscellaneous Correction
Resolved
01/21/2022
Documents & Images
Date Uploaded File Type Document Name
03/02/2021 Application Form APPLICATION
03/02/2021 66 WOODSIDE RIDGE ROOF LAYOUT
03/02/2021 LOT 66 FINAL
03/02/2021 2648535 RF SEAL 02122021
03/02/2021 W2 #66 - Carbondale - Craftsman - Sheets- signed
03/03/2021 Approved Plans APPROVED PLANS
03/03/2021 Approved Plans APPROVED TRUSS DRAWINGS
03/03/2021 Approved Plans APPROVED TRUSS LAYOUT
03/03/2021 Plot Plan APPROVED PLOT PLAN
03/04/2021 Receipt Receipt for transaction:2021-001069
03/04/2021 Receipt Receipt for transaction:2021-001087
03/04/2021 Letter DS Building Permit
03/04/2021 Letter DS Building Permit
04/28/2021 Letter INSPECTION SUMMARY
04/29/2021 Lot 66 Woodside Ridge footing inspection
05/14/2021 Letter INSPECTION SUMMARY
05/14/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter INSPECTION SUMMARY
08/05/2021 Letter INSPECTION SUMMARY
08/05/2021 Letter INSPECTION SUMMARY
09/09/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
10/04/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
11/18/2021 Letter INSPECTION SUMMARY
01/18/2022 Letter Codes Temporary Certificate of Occupancy
01/18/2022 Receipt Receipt for transaction:2022-000291
01/21/2022 Letter Codes Final Certificate of Occupancy
01/21/2022 Letter Field Certificate of Occupancy
01/21/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: