Permit Application Status

PRRES20210283


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210283
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - ROOF TRUSS - COVERED DECK
01/20/2021
02/16/2021
08/11/2021
10/13/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/18/2021 02/16/2021
Brandon Kalwei
Rear yard dimension
Corrective Action Required
02/16/2021

The rear yard demision(s) must be provided on the plot plan.
Deck location
Corrective Action Required
02/16/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Residential Plan Review Approved 02/18/2021 02/16/2021
Brandon Kalwei
Planning Review (RES) Approved 02/11/2021 02/09/2021
Victoria Nelson
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,301.17 $1,301.17 Paid 02/16/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 02/16/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/16/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/16/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/16/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/16/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/06/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/06/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/06/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Passed 3/9/2021 03/09/2021
Misc
Informational
03/09/2021
(2) 24 x 36 DECK PIERS POURED WITH FOOTINGS
Footing Inspection - Residential Partial 3/9/2021 03/09/2021
Misc
Corrective Action Required
03/09/2021
- PROVIDE GEOTECHNICAL ENGINEER'S REPORT VERIFYING 2000 PSF BEARING S-3.1 - - UFER FOUNDATION WALL REAR OF GARAGE -
Erosion Control Inspection Residential Failed 4/1/2021 04/01/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/01/2021
- POST ADDRESS - - MAINTAIN SILT FENCE - DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 4/1/2021 4/1/2021 04/01/2021
Footing Inspection - Residential Passed 4/13/2021 (8:30) 4/13/2021 04/13/2021
Misc
Resolved
04/13/2021
- PROVIDE GEOTECHNICAL ENGINEER'S REPORT VERIFYING 2000 PSF BEARING S-3.1 - - REAR FOOTING & BASEMENT PIER PADS ENLARGED PER ENGINEER'S LETTER - - UFER FOUNDATION WALL REAR OF GARAGE -
All Rough Inspection - Residential Not Ready 5/4/2021 5/4/2021 05/04/2021
Misc
Corrective Action Required
05/04/2021
-NO CITY APPROVED PLANS, TRUSS DRAWINGS & LAYOUT ON SITE - NO INSPECTION NAIL STHD14 HOLDDOWNS PROVIDE SOLID BLOCKING AT SHEATHING BREAKS AT PFH PORTAL FRAME
All Rough Inspection - Residential Partial 6/21/2021 6/21/2021 06/21/2021
Misc
Partial Correction
06/21/2021
GARAGE PORTAL FRAMING OK TO COVER COVERED DECK TRUSSES OK TO COVER FRONT PORCH TRUSSES OK TO COVER : ONLY THE ABOVE ITEMS INSPECTED : SHEATHING REQUIRES NAILING PER CODE BEFORE INSTALLING HARDIE BOARD SIDING
All Rough Inspection - Residential Not Ready 6/30/2021 6/30/2021 06/30/2021
Misc
Partial Correction
06/21/2021
GARAGE PORTAL FRAMING OK TO COVER COVERED DECK TRUSSES OK TO COVER FRONT PORCH TRUSSES OK TO COVER : ONLY THE ABOVE ITEMS INSPECTED : SHEATHING REQUIRES NAILING PER CODE BEFORE INSTALLING HARDIE BOARD SIDING THIS HAS IS COVERED WITH TYVEK UNABLE TO VERIFY NAIL PATTERN BELOW AREAS ARE NOT NAILED PER CODE MASTER BEDROOM BOTH SIDES OF WINDOWS,BED # 2 / DINING ROOM AT DEAD SPACE, GREAT ROOMSE CORNER,FRONT DOOR, OFFICE CLOSET, BASEMENT REAR WALL, SOUTH WALL
Gas Service Inspection - Residential Failed 7/1/2021 7/1/2021 07/01/2021
Miscellaneous Correction
Corrective Action Required
07/01/2021
PROVIDE MINIMUM 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Failed 7/1/2021 7/1/2021 07/01/2021
Misc
Partial Correction
06/30/2021
GARAGE PORTAL FRAMING OK TO COVER COVERED DECK TRUSSES OK TO COVER FRONT PORCH TRUSSES OK TO COVER : ONLY THE ABOVE ITEMS INSPECTED : SHEATHING REQUIRES NAILING PER CODE BEFORE INSTALLING HARDIE BOARD SIDING THIS HAS IS COVERED WITH TYVEK UNABLE TO VERIFY NAIL PATTERN BELOW AREAS ARE NOT NAILED PER CODE MASTER BEDROOM BOTH SIDES OF WINDOWS,BED # 2 / DINING ROOM AT DEAD SPACE, GREAT ROOMSE CORNER,FRONT DOOR, OFFICE CLOSET, BASEMENT REAR WALL, SOUTH WALL Tighten 5/8!anchor bolt garage portal frame Provide anchor bolts within 12" of plate break garage north wall Seal top plate penetration south wall garage Fire block dead space mud room / refrigerator / range Seal bottom plate at duct microwave, master bath, master closet Seal top plate penetration doorbell in office Provide straps CS-PF bracing method Foyer, Fireplace, covered deck, dining, master per plan Seal top plate penetration foyer Fire blocking fireplace Provide 4 studs at GT bearing points per roof plan @ great room Fire block dead spaces dining room Seal top plate penetrations bed # 2 Seal bore in floor bath b# 2 Seal top & bottom plate penetrations powder room Provide hangers per truss schedule master bed Nail studs in corners of braced wall panels Provide roof vent at covered deck per plan Seal top plate penetrations master closet Provide anchor bolts within 12" of plate break & end of plate at patio door Seal top plate penetrations rec room / bed # 4 Provide anchor bolt at plate break & tighten anchor bolts bed #4 Provide 3 studs corner bed # 4 closet Seal top plate penetration bath Fire block bed # 3 above vanity Provide vertical fire block every 10' bed #3 & bed 4 closet Tighten anchor bolts throughout basement Tyvek tape nail penetrations throughout Install doors Provide flashing above horizontal trim @ windows
All Rough Inspection - Residential Not Ready 7/7/2021 7/7/2021 07/07/2021
Misc
Partial Correction
07/01/2021
GARAGE PORTAL FRAMING OK TO COVER COVERED DECK TRUSSES OK TO COVER FRONT PORCH TRUSSES OK TO COVER OK TO INSTALL HARDIE BOARD SIDING Seal duct at bottom plate master tub Seal top & bottom plate penetrations powder room Provide roof vent at covered deck per plan Provide vertical fire block every 10' bed #3 & bed 4 closet ( seal gaps ) Provide flashing above horizontal trim @ windows
Electrical Service Inspection Passed 7/7/2021 7/7/2021 07/07/2021
Gas Service Inspection - Residential Passed 7/7/2021 7/7/2021 07/07/2021
Miscellaneous Correction
Resolved
07/07/2021
All Rough Inspection - Residential Failed 7/12/2021 7/12/2021 07/12/2021
Misc
Partial Correction
07/07/2021
GARAGE PORTAL FRAMING OK TO COVER COVERED DECK TRUSSES OK TO COVER FRONT PORCH TRUSSES OK TO COVER OK TO INSTALL HARDIE BOARD SIDING Provide flashing above horizontal trim @ windows
Sewer Service Inspection - R Partial 7/29/2021 (11:30) 7/29/2021 07/29/2021
Misc
Informational
07/29/2021
PARTIAL TAP TO FRONT STOOP NEEED TO BORE WALL FOR GRINDER PUMP
Sewer Service Inspection - R Passed 7/30/2021 (8:00) 7/30/2021 07/30/2021
Misc
Informational
07/29/2021
PARTIAL TAP TO FRONT STOOP BORE WALL FOR GRINDER PUMP COMPLETE
Water Service Inspection - R Passed 8/2/2021 (10:45) 8/2/2021 08/02/2021
Driveway Inspection Partial 8/3/2021 08/03/2021
Misc
Informational
08/03/2021
Forms were placed and aggregate was present and compacted. RP 8-3-21
Driveway Inspection Passed 8/6/2021 8/6/2021 08/06/2021
Misc
Informational
08/03/2021
Forms were placed and aggregate was present and compacted. RP 8-3-21
Misc
Informational
08/06/2021
Finished driveway meets LS specs. RP 8-6-21
All Rough Inspection - Residential Passed 8/17/2021 8/17/2021 08/17/2021
Misc
Resolved
08/17/2021
GARAGE PORTAL FRAMING OK TO COVER COVERED DECK TRUSSES OK TO COVER FRONT PORCH TRUSSES OK TO COVER OK TO INSTALL HARDIE BOARD SIDING
Occupancy Inspection - Codes Residential Failed 10/5/2021 10/5/2021 10/05/2021
Misc
Resolved
10/05/2021
Miscellaneous Correction
Corrective Action Required
10/05/2021
Obtain lawn irrigation permit & Submit back flow certification for lawn irrigation Land sewer tracer wire in a box at grade Pay outstanding fees Provide final grade @ sod Provide gutters & downspouts, splash blocks Provide tempered glass sidelights front door Complete stone front stoop & garage Provide guardrail front stoop over 30" Provide self closing & latching door garage to dwelling Remove dust covers smoke detectors Provide two 3" screws in each exterior door hinge & strike plate deck & patio Repair siding at light fixture patio seal top of fixture Provide through bolts deck beam to post connection Address full height continuous 6x6 deck post per plan Provide clamp ac whip Sump shall discharge 36" from foundation Address numbers shall be contrasting color to trim Remove sediment build up at gutter buddy
Occupancy Inspection - Codes Residential Temporary C of O 10/8/2021 10/8/2021 10/08/2021
Miscellaneous Correction
Corrective Action Required
10/05/2021
Obtain lawn irrigation permit Provide final grade @ sod Provide splash blocks Provide tempered glass sidelights front door ( BACKORDERED) Seal top of fixture at patio door after siding repair Provide through bolts deck beam to post connection ( DECK BEAM AGAINST STAIRWAY MISSING THROUGH BOLTS OR LEDGER LOCKS 0 Address full height continuous 6x6 deck post per plan Sump shall discharge 36" from foundation
Occupancy Inspection - Codes Residential Full C of O 10/13/2021 10/13/2021 10/13/2021
Miscellaneous Correction
Resolved
10/13/2021
Provide final grade @ sod Provide splash blocks Provide tempered glass sidelights front door ( BACKORDERED) Seal top of fixture at patio door after siding repair Provide through bolts deck beam to post connection ( DECK BEAM AGAINST STAIRWAY MISSING THROUGH BOLTS OR LEDGER LOCKS 0 Address full height continuous 6x6 deck post per plan Sump shall discharge 36" from foundation
Documents & Images
Date Uploaded File Type Document Name
01/20/2021 Application Form W0 #80 - Permit App
02/09/2021 80 WOODSIDE RIDGE ROOF LAYOUT
02/09/2021 210213
02/09/2021 W0 #80 - Pikewood - Craftsman - Sheets- signed
02/09/2021 LOT 80 FINAL;
02/12/2021 Approved Plans APPROVED PLANS
02/12/2021 Approved Plans APPROVED TRUSS DRAWINGS
02/12/2021 Approved Plans APPROVED TRUSS LAYOUT
02/12/2021 Letter Codes Residential Plan Review
02/16/2021 Plot Plan APPROVED PLOT PLAN
02/16/2021 Receipt Receipt for transaction:2021-000724
02/16/2021 Letter DS Building Permit
03/01/2021 Scope of Work Statement - W0 #80
03/01/2021 W0 #80 - Revised Pikewood - Craftsman - Sheets- signed
03/01/2021 Approved Plans APPROVED PLANS
03/09/2021 Letter INSPECTION SUMMARY
03/09/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
04/02/2021 80 Woodside Ridge-Subgrade
04/13/2021 Letter INSPECTION SUMMARY
04/14/2021 Lot 80 Woodside Ridge Soil Re-Inspection
05/04/2021 Letter INSPECTION SUMMARY
06/21/2021 Letter INSPECTION SUMMARY
06/30/2021 Letter INSPECTION SUMMARY
07/01/2021 Letter INSPECTION SUMMARY
07/01/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
08/02/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/17/2021 Letter INSPECTION SUMMARY
08/24/2021 80 Woodside Ridge deck post letter
10/05/2021 Letter INSPECTION SUMMARY
10/05/2021 80 Woodside Ridge deck post and beam attachment letter
10/06/2021 Receipt Receipt for transaction:2021-007821
10/08/2021 317 Ambersham Dr Back Flow
10/08/2021 Letter Codes Temporary Certificate of Occupancy
10/11/2021 LOT 80 ASBUILT
10/13/2021 Letter Codes Final Certificate of Occupancy
10/25/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home