Permit Application Status

PRRES20204439


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204439
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT
11/23/2020
12/18/2020
07/22/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
PERMITTING@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 12/17/2020 12/17/2020
Shannon McGuire
Plot Plan Review Approved 11/30/2020 12/17/2020
Brandon Kalwei
Residential Plan Review Approved 11/30/2020 11/24/2020
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $989.04 $989.04 Paid 12/18/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/18/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/18/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/18/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/18/2020
8331507-Sewer Connection Fee $420.00 $420.00 Paid 12/18/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/20/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/20/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/20/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 07/20/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Passed 12/28/2020 01/20/2021
Misc
Informational
01/20/2021
3RD PARTY PIERS BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL POURED WITH FOOTING
Footing Inspection - Residential Passed 12/28/2020 01/20/2021
Misc
Informational
01/20/2021
3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL
Erosion Control Inspection Residential Failed 1/29/2021 01/29/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/29/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
Underslab Plumbing Inspection - Residential Failed 1/29/2021 1/29/2021 01/29/2021
Misc
Corrective Action Required
01/29/2021
- PROVIDE INTERIOR DRAIN TILE -
Underslab Plumbing Inspection - Residential Passed 2/1/2021 2/1/2021 02/01/2021
Misc
Resolved
02/01/2021
Piers/Caissons Inspection - Residential Passed 2/26/2021 (1:00) 2/26/2021 02/26/2021
Misc
Informational
02/26/2021
(2) 24 X 36 W/ (4) # 4 VERT BARS PER PLAN
Sewer Service Inspection - R Passed 3/11/2021 3/11/2021 03/11/2021
Water Service Inspection - R Passed 3/11/2021 (10:00) 3/11/2021 03/11/2021
Electrical Service Inspection Passed 4/7/2021 4/7/2021 04/07/2021
Gas Service Inspection - Residential Failed 4/7/2021 4/7/2021 04/07/2021
G2417.4.1 Test Pressure
Corrective Action Required
04/07/2021
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Failed 4/7/2021 4/7/2021 04/07/2021
Miscellaneous Correction
Corrective Action Required
04/07/2021
-Gas pressure gauge only at 4 psi -Provide angle clips at end joist to ledger connection at deck -Provide (2) Through bolts at each beam to post connection at deck -Address exterior sheathing not connected to top plate throughout -Complete exterior sheathing nailing pattern -Unable to verify PFH nailing pattern at exterior studs -Fasten top plate to header at PFH with (2) rows of 16d sinkers 3"OC per detail -Nail corners and intersecting studs at braced walls per code -Bocca plate at dwv in bath 2 -Provide structural strap at exterior wall top plate bored more than 50% at bath 2 -Seal gap in dead spaces at laundry/ pantry -Missing stud in bath 2 -Seal dead space at dining/ foyer -Fire block/ seal dead spaces at dining/ stairs both sides -Fire block above fireplace and top of fur out at fireplace -Replace damaged studs under window by fireplace -Strap top plate not lapped 24" at master/ master bath -Missing H2.5 at master bath/ master -Missing H2.5 at master bath wc -Fireblock top of fur out wall at dwv in basement wall bar/ unfinished area -Seal fireblocking at top of fur out wall throughout -Seal penetration in vertical FB at SW corner -Sister studs to over notched studs on foundation wall rec room -FB soffit line at posts -FB beam webs in finished walls -Address beam not fully bearing on post rec room -Seal all gaps and penetrations in vertical fireblocking in bed 3 and bed 4 -Vertical FB spaced greater than 10' OC in bed 3 and bed 4 -Insulate and block cantilever joists in unfinished space -Identify grounding conductor at ufer -Support gas line between joists in rec room -Provide lateral truss bracing per plans -Provide missing truss hangers at jack trusses per plans
Gas Service Inspection - Residential Not Ready 4/21/2021 4/21/2021 04/21/2021
G2417.4.1 Test Pressure
Corrective Action Required
04/07/2021
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Not Ready 4/21/2021 4/21/2021 04/21/2021
Miscellaneous Correction
Corrective Action Required
04/07/2021
-Gas pressure gauge only at 4 psi -Provide angle clips at end joist to ledger connection at deck -Provide (2) Through bolts at each beam to post connection at deck -Complete exterior sheathing nailing patter -Fasten top plate to header at PFH with (2) rows of 16d sinkers 3"OC per detail -Nail corners and intersecting studs at braced walls per code -Seal gap in dead spaces at laundry/ pantry -Seal dead space at dining/ foyer -Fire block/ seal dead spaces at dining/ stairs both sides -Fire block above fireplace and top of fur out at fireplace -Replace damaged studs under window by fireplace -Missing H2.5 at master bath/ master -Fireblock top of fur out wall at dwv in basement wall bar/ unfinished area -Seal fireblocking at top of fur out wall throughout -Seal penetration in vertical FB at SW corner -Sister studs to over notched studs on foundation wall rec room -FB soffit line at posts -FB beam webs in finished walls -Address beam not fully bearing on post rec room -Seal all gaps and penetrations in vertical fireblocking in bed 3 and bed 4 -Vertical FB spaced greater than 10' OC in bed 3 and bed 4 -Insulate and block cantilever joists in unfinished space -Identify grounding conductor at ufer -Support gas line between joists in rec room -Provide lateral truss bracing per plans -Provide missing truss hangers at jack trusses per plans
Gas Service Inspection - Residential Failed 4/22/2021 4/22/2021 04/22/2021
G2417.4.1 Test Pressure
Corrective Action Required
04/21/2021
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Not Ready 4/22/2021 4/22/2021 04/22/2021
Miscellaneous Correction
Corrective Action Required
04/21/2021
-Provide (2) Through bolts at each beam to post connection at deck -Complete exterior sheathing nailing patter -Fasten top plate to header at PFH with (2) rows of 16d sinkers 3"OC per detail -Nail corners and intersecting studs at braced walls -Fireblock top of fur out wall at dwv in basement wall bar/ unfinished area -Seal fireblocking at top of fur out wall throughout -Seal all gaps and penetrations in vertical fireblocking in bed 3 and bed 4 -Vertical FB spaced greater than 10' OC in bed 3 and bed 4 -Provide lateral truss bracing per plans
All Rough Inspection - Residential Failed 4/26/2021 4/26/2021 04/26/2021
Miscellaneous Correction
Corrective Action Required
04/22/2021
*OK TO INSULATE-DO NOT SHEET ROCK, -LEAVE PFH EXPOSED FOR INSPECTION -Provide (2) Through bolts at each beam to post connection at deck -Complete exterior sheathing nailing patter -Fasten top plate to header at PFH with (2) rows of 16d sinkers 3"OC per detail
Gas Service Inspection - Residential Passed 4/26/2021 4/26/2021 04/26/2021
G2417.4.1 Test Pressure
Resolved
04/26/2021
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Passed 4/27/2021 4/27/2021 04/27/2021
Miscellaneous Correction
Resolved
04/27/2021
Driveway Inspection Partial 4/29/2021 4/29/2021 04/29/2021
Misc
Informational
04/29/2021
4-29-21 1:35pm The forms are set and the aggregate is compacted.
Driveway Inspection Passed 5/7/2021 5/7/2021 05/07/2021
Misc
Informational
04/29/2021
4-29-21 1:35pm The forms are set and the aggregate is compacted.
Misc
Informational
05/07/2021
Finished driveway meets LS specs. RP 5-7-21
Plot Plan Inspection Passed 7/19/2021 07/19/2021
Occupancy Inspection - Codes Residential Failed 7/19/2021 7/19/2021 07/19/2021
Miscellaneous Correction
Corrective Action Required
04/27/2021
-Provide (2) 1/2" through bolts at beam to post connections - PAY OUTSTANDING FEES - - SUBMIT BACKFLOW CERTIFICATION - Provide sod & splash blocks Install Handrail at deck stairs per code Address 6x6 cedar deck post not continuous per plan Sump discharge 36" from foundation Seal top light fixtures, meter can, AC disconnect, exterior penetrations Provide guardrail front stoop over 30" to grade Provide 6" clearance wood siding to finish grade
Occupancy Inspection - Codes Residential Full C of O 7/22/2021 7/22/2021 07/22/2021
Miscellaneous Correction
Resolved
07/22/2021
Documents & Images
Date Uploaded File Type Document Name
11/23/2020 Application Form PERMIT AND LICENSE TAX APPLICATION
11/24/2020 Approved Plans APPROVED TRUSS DRAWINGS
11/24/2020 Approved Plans APPROVED TRUSS DRAWINGS
12/10/2020 W2 #5 - Jasmine - Mediterranean - Sheets- signed
12/17/2020 Approved Plans APPROVED PLANS
12/17/2020 Plot Plan APPROVED PLOT PLAN
12/18/2020 Receipt Receipt for transaction:2020-008112
12/18/2020 Letter DS Building Permit
01/20/2021 W2 Lot 5 - 106 nw Grady Ct-- Footing inspection
01/20/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter INSPECTION SUMMARY
02/26/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
04/26/2021 Letter INSPECTION SUMMARY
04/26/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter INSPECTION SUMMARY
04/29/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
07/12/2021 5 Woodside Ridge deck post connection letter
07/19/2021 Letter INSPECTION SUMMARY
07/19/2021 Letter INSPECTION SUMMARY
07/20/2021 Receipt Receipt for transaction:2021-005754
07/20/2021 Letter Backflow Letter
07/22/2021 Letter Field Certificate of Occupancy
07/22/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home