Summary
PRRES20204103
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
11/02/2020
11/11/2020
05/02/2021
04/18/2022
Locations
Contacts
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210, Phone:(816) 524-5245  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
AUBREY@PFEIFERHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/12/2020 11/10/2020
Kim Brennan
Residential Plan Review Approved 11/12/2020 11/10/2020
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
11/10/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) No square footage shown for unfinished basement
Plot Plan Review Approved 11/05/2020 11/09/2020
Kim Brennan
Deck location
Corrective Action Required
11/03/2020

Deck location, with dimensions to property lines must be provided on the plot plan. Also, please show that this is a covered patio
Contours, spot elevations and arrows
Corrective Action Required
11/03/2020

Contours, spot elevations and drainage flow arrows (as required) shall be provided on the lot. Please add countours
Basement opening elevations
Corrective Action Required
11/03/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
As-graded plot plan
Corrective Action Required
11/03/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Rejected 11/05/2020 11/03/2020
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
11/03/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) No square footage shown for unfinished basement
Fees
Paid Fees Amount Paid Owing Date Paid
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/11/2020
Valuation Fee New Single Family $1,112.94 $1,112.94 Paid 11/11/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 11/11/2020
Water Meter Fee $455.54 $455.54 Paid 11/11/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 11/11/2020
Right of Way Permit Fee $80.00 $80.00 Paid 11/11/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/16/2020 (1:30) 12/16/2020 12/16/2020
Erosion Control Inspection Residential Failed 01/21/2021
Misc
Corrective Action Required
01/21/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -no further inspections until issues are resolved Post site address
Underslab Plumbing Inspection - Residential Failed 1/22/2021 1/22/2021 01/22/2021
Misc
Corrective Action Required
01/22/2021
Inspection denied. No further inspections until erosion control issues are resolved per erosion control inspection report
Underslab Plumbing Inspection - Residential Failed 1/25/2021 1/25/2021 01/25/2021
Misc
Corrective Action Required
01/22/2021
Inspection denied. No further inspections until erosion control issues are resolved per erosion control inspection report
Erosion Control Inspection Residential Failed 01/25/2021
Misc
Corrective Action Required
01/21/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days. Re-establish at front curb line -no further inspections until issues are resolved Post site address
Sewer Service Inspection - R Passed 1/26/2021 01/26/2021
Water Service Inspection - R Passed 1/28/2021 1/28/2021 01/28/2021
Underslab Plumbing Inspection - Residential Passed 2/1/2021 2/1/2021 02/01/2021
Misc
Corrective Action Required
01/25/2021
-Post address
Erosion Control Inspection Residential Failed 2/1/2021 2/1/2021 02/01/2021
Misc
Corrective Action Required
01/25/2021
-Erosion control requires continuous maintenance. -Clean debris from storm inlet. -Port a John is not to be placed on top of inlet. -Remove trash from site -Post site address
Erosion Control Inspection Residential Passed 2/2/2021 2/2/2021 02/02/2021
Misc
Resolved
02/02/2021
-Erosion control requires continuous maintenance. -Clean debris from storm inlet. -Port a John is not to be placed on top of inlet. -Remove trash from site -Post site address
Piers/Caissons Inspection - Residential Passed 3/22/2021 (9:00) 3/22/2021 03/22/2021
Erosion Control Inspection Residential Failed 05/18/2021
Misc
Corrective Action Required
05/18/2021
-erosion control requires continuous maintenance. Repair damaged sections within 48 hours no further inspections until resolved
Gas Service Inspection - Residential Failed 5/28/2021 5/28/2021 05/27/2021
Misc
Corrective Action Required
05/27/2021
Gas piping is prohibited in return air plenums, master suite RA under great room fireplace. G2415.3
Electrical Service Inspection Passed 6/2/2021 6/2/2021 06/02/2021
Gas Service Inspection - Residential Failed 6/2/2021 6/2/2021 06/02/2021
Misc
Corrective Action Required
05/27/2021
Gas piping is prohibited in return air plenums, master suite RA under great room fireplace. G2415.3
Misc
Corrective Action Required
06/02/2021
Unable to verify this issue has been resolved
All Rough Inspection - Residential Failed 6/2/2021 6/2/2021 06/02/2021
Misc
Corrective Action Required
06/02/2021
-Unable to verify exterior sheathing fastening at portal opening -Finish nailing interior tension straps at portal frame, use all nail holes -Page S3.0 missing from plans -Provide engineered solution for rafters bearing on multiple plates -Provide rafter ties where rafters are perpendicular to joists per code -Fireblock Plate Penetrations throughout, some locations marked but low voltage contractor onsite -Six studs required at exterior walls, garage beam -Nail Joist laps per code -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Midpoint strap for all vertical 2 inch and smaller DWV -Snow block above dining -Strap non-Continuous studs -Address Joists not properly fastened to rafters -Address missing section of top plate above fireplace -2 full height king studs either side of header above entry per plan -Maintain required minimum airspace at gas vent insulation shields -Five bearing studs under beam at main floor chase -Provide joist hangers above garage/dwelling entry at header -Fireblock through floor Penetrations under fireplace With a proved fire blocking materials -Provide minimum 16g galvanized metal ties 1.5” wide at over bored top plates of interior load bearing walls. Fasten ties across and to the plate at each side of the opening with minimum 4-10dx1.5” at each side of straps. The metal tie must extend a minimum of 6” past the opening. See figure R602.6.1 Master bed/bath wall -Provide joist hangers at joist to beam and beam to beam connections above master closet -Minimum 12” field 6” edge exterior sheathing fastening -Provide proper hip and Valley rafter end bearing -Provide bearing support of stair landing -Fireblock vertical to horizontal, concealed space/drop ceiling at basement bath between bedrooms -Anchor bolt required within 12 inches a plate end, basement bath -Fireblock Penetration in Wood fire block, basement bath closet -Grounding electrode Conductor connection to concrete encased electrode to remain accessible -Collar ties at Ridges -Provide Perlins per plan -Provide roof support per plan -Complete low-voltage installation in basement
All Rough Inspection - Residential Failed 6/28/2021 6/28/2021 06/28/2021
Misc
Corrective Action Required
06/02/2021
-Unable to verify exterior sheathing fastening at portal opening -Page S3.0 missing from plans -Provide engineered solution for rafters bearing on multiple plates -Provide rafter ties where rafters are perpendicular to joists per code 2018 IRC section R802.5.2 -Fireblock Plate Penetrations, locations marked -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Midpoint strap for all vertical 2 inch and smaller DWV -Provide joist hanger beam to beam connections above master closet, triple -Provide proper hip and Valley rafter end bearing -Fireblock vertical to horizontal, concealed space/drop ceiling at basement bath between bedrooms -Fireblock Penetration in Wood fire block, basement bath closet -Grounding electrode Conductor connection to concrete encased electrode to remain accessible -Collar ties at Ridges -Provide Perlins per plan -Provide roof support per plan
Gas Service Inspection - Residential Passed 6/28/2021 6/28/2021 06/28/2021
Misc
Resolved
06/28/2021
Gas piping is prohibited in return air plenums, master suite RA under great room fireplace. G2415.3
Misc
Resolved
06/28/2021
Unable to verify this issue has been resolved
All Rough Inspection - Residential Passed 7/15/2021 7/15/2021 07/15/2021
Misc
Informational
07/15/2021
-Grounding electrode Conductor connection to concrete encased electrode to remain accessible ( IN POCKET CLOSET OF BEDROOM WITH SERVICE PANEL)
Sidewalk Inspection Partial 8/20/2021 8/20/2021 08/20/2021
Misc
Informational
08/20/2021
Forms were placed and aggregate was present and compacted. RP 8-20-21
Driveway Inspection Partial 8/20/2021 8/20/2021 08/20/2021
Misc
Informational
08/20/2021
Forms were placed and aggregate was present and compacted. RP 8-20-21
Sidewalk Inspection Passed 8/27/2021 8/27/2021 08/27/2021
Misc
Informational
08/20/2021
Forms were placed and aggregate was present and compacted. RP 8-20-21
Misc
Informational
08/27/2021
Sidewalk meets LS and ADA specs. RP 8-27-21
Driveway Inspection Passed 8/27/2021 8/27/2021 08/27/2021
Misc
Informational
08/20/2021
Forms were placed and aggregate was present and compacted. RP 8-20-21
Misc
Informational
08/27/2021
Driveway meets LS and ADA specs. RP 8-27-21
Occupancy Inspection - Codes Residential Failed 12/21/2021 12/21/2021 12/21/2021
Miscellaneous Correction
Corrective Action Required
12/21/2021
- Erosion control and methods must be in place until sod is down - obtain an irrigation permit and submit a back flow certification - Complete final grading and sod - provide spark rings on kitchen counter outlets and switches - Label non GFCI outlet in garage - Provide spark rings for outlets at bar counter - Tighten and break off screw to back flow device at water main - Label non GFCI at sump pump - Provide clearance of PEX from Bvent above water heater - Label AV outlet non GFCI in basement - Provide proper light for patio fan
Occupancy Inspection - Codes Residential Temporary C of O 12/27/2021 12/27/2021 12/27/2021
Miscellaneous Correction
Corrective Action Required
12/21/2021
- submit a back flow certification - Complete final grading and sod
Plot Plan Inspection Passed 4/18/2022 04/18/2022
Erosion Control Inspection Residential Passed 4/18/2022 04/18/2022
Misc
Resolved
04/18/2022
Occupancy Inspection - Codes Residential Full C of O 4/18/2022 4/18/2022 04/18/2022
Miscellaneous Correction
Resolved
04/18/2022
Documents & Images
Date Uploaded File Type Document Name
11/02/2020 Application Form Permit Application
11/02/2020 Application Form License Tax Form
11/03/2020 Sealed Plot Plan WV1463 Bristol 3065
11/03/2020 Letter Codes Residential Plan Review
11/04/2020 Approved Plans Approved Drawings
11/09/2020 Plot Plan Approved Plot Plan
11/11/2020 Receipt Receipt for transaction: 2020-007513
11/11/2020 Letter DS Building Permit
12/16/2020 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter INSPECTION SUMMARY
02/02/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/27/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/28/2021 Letter INSPECTION SUMMARY
06/28/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter Codes Temporary Certificate of Occupancy
04/18/2022 Letter INSPECTION SUMMARY
04/18/2022 Letter Codes Final Certificate of Occupancy
04/18/2022 Letter Field Certificate of Occupancy
04/18/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home