Permit Application Status

PRRES20203773


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20203773
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - UNFINISHED BASEMENT - SUSPENDED SLAB
10/16/2020
11/02/2020
09/12/2022
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
JENNIFER@IQHOMEBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/20/2020 10/22/2020
Dylan Eppert
Sidewalks
Corrective Action Required
10/20/2020

Sidewalks with dimensions must be provided on the plot plan.
Basement egress
Corrective Action Required
10/20/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Residential Plan Review Approved 10/20/2020 10/20/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,186.86 $1,186.86 Paid 11/02/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 11/02/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 11/02/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 11/02/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/02/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/02/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/29/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/29/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/29/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 06/29/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/29/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 11/24/2020 11/24/2020
Misc
Corrective Action Required
11/24/2020
-Erosion control requires continuous maintenance. Repair damaged section at rear and establish methods at curb line within 2 businesses days -immediate street cleanup required -establish gravel filter at driveway -provide building address -no further inspections until complete
Footing Inspection - Residential Passed 11/24/2020 (9:30) 11/24/2020 11/24/2020
Underslab Plumbing Inspection - Residential Passed 12/29/2020 12/29/2020 12/29/2020
Sewer Service Inspection - R Passed 1/11/2021 01/11/2021
Water Service Inspection - R Passed 1/13/2021 01/13/2021
Erosion Control Inspection Residential Failed 2/3/2021 02/03/2021
Misc
Partial Correction
02/03/2021
Remove debris from curb/gutter
All Rough Inspection - Residential Partial 2/11/2021 2/11/2021 02/11/2021
Misc
Informational
02/11/2021
Portal frame approved
Erosion Control Inspection Residential Passed 1/11/2021 02/11/2021
Misc
Resolved
02/11/2021
Remove debris from curb/gutter
All Rough Inspection - Residential Failed 3/24/2021 3/24/2021 03/24/2021
Misc
Informational
02/11/2021
Portal frame approved
Misc
Corrective Action Required
03/24/2021
city approved plans required to be onsite for inspections
All Rough Inspection - Residential Not Ready 3/25/2021 3/25/2021 03/25/2021
Misc
Informational
03/24/2021
Portal frame approved
Misc
Corrective Action Required
03/24/2021
city approved plans required to be onsite for inspections 03/25/2021 1:34pm no plans onsite
Piers/Caissons Inspection - Residential Passed 3/29/2021 (9:00) 3/29/2021 03/29/2021
Electrical Service Inspection Passed 3/29/2021 3/29/2021 03/29/2021
Gas Service Inspection - Residential Failed 3/29/2021 3/29/2021 03/29/2021
Misc
Corrective Action Required
03/29/2021
pressure test gas piping, minimum 10PSI for 15 minutes
All Rough Inspection - Residential Failed 3/29/2021 3/29/2021 03/29/2021
Misc
Informational
03/25/2021
Portal frame approved
Misc
Corrective Action Required
03/25/2021
-Fireblock top plate Penetrations in Garage, kitchen, master bed -Provide nail plate protection at DWV top plate penetration, main level bath -Complete bath exhaust duct installation -Address Removed Section of top plate in pantry -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Connect gas piping to fireplace -Fireblock penetration and wood fire block at garage soffit to wall connection -Pressure test gas piping, minimum 10 psi for 15 minutes -Anchor bolt required within 12 inches of plate splice, east foundation wall at unused rebar ground -Protect NM conductors from physical damage minimum 6” AFF at floor penetrations -Repair/replace solid blocking over beams Removed/damaged by other trades -Fireblock top plate penetration, southwest bedroom -Provide nail plate protection at Conductor stud penetration in southwest bedroom, master bedroom -Minimum 12” field 6” edge exterior sheathing fastening throughout. Top of sheathing is below the top plate on north and east second floor exterior walls, also ensure fasteners are penetrating studs
Gas Service Inspection - Residential Passed 4/1/2021 4/1/2021 04/01/2021
Misc
Resolved
04/01/2021
pressure test gas piping, minimum 10PSI for 15 minutes
All Rough Inspection - Residential Not Ready 4/1/2021 4/1/2021 04/01/2021
Misc
Informational
03/29/2021
Portal frame approved
Misc
Corrective Action Required
03/29/2021
-Provide nail plate protection at DWV top plate penetration, main level bath -Address Removed Section of top plate in pantry -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Fireblock penetration in wood fire block at garage soffit to wall connection -Anchor bolt required within 12 inches of plate splice, east foundation wall at unused rebar ground -Repair/replace full depth solid blocking over beams Removed/damaged by other trades -Minimum 12” field 6” edge exterior sheathing fastening throughout. ensure fasteners are penetrating studs throughout
All Rough Inspection - Residential Not Ready 4/5/2021 4/5/2021 04/05/2021
Misc
Informational
04/01/2021
Portal frame approved
Misc
Corrective Action Required
04/01/2021
-Provide nail plate protection at DWV top plate penetration, main level bath -Address Removed Section of top plate in pantry, provide straps on both sides -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Fireblock penetration in wood fire block at garage soffit to wall connection -Anchor bolt required within 12 inches of plate splice, east foundation wall at unused rebar ground -Repair/replace full depth solid blocking over beams Removed/damaged by other trades -Minimum 12” field 6” edge exterior sheathing fastening throughout. ensure fasteners are penetrating studs throughout
All Rough Inspection - Residential Failed 4/9/2021 4/9/2021 04/09/2021
Misc
Informational
04/05/2021
Portal frame approved
Misc
Corrective Action Required
04/05/2021
-Minimum 12” field 6” edge exterior sheathing fastening throughout. ensure fasteners are penetrating studs throughout. Master closet
All Rough Inspection - Residential Passed 4/12/2021 4/12/2021 04/12/2021
Misc
Resolved
04/12/2021
Portal frame approved
Misc
Resolved
04/12/2021
-Minimum 12” field 6” edge exterior sheathing fastening throughout. ensure fasteners are penetrating studs throughout. Master closet
Driveway Inspection Passed 6/16/2021 6/16/2021 06/16/2021
Occupancy Inspection - Codes Residential Failed 6/25/2021 6/25/2021 06/25/2021
Misc
Corrective Action Required
06/25/2021
Not ready for inspection, no building address
Occupancy Inspection - Codes Residential Failed 6/29/2021 6/29/2021 06/29/2021
Misc
Corrective Action Required
06/25/2021
-All outstanding fees to be paid in full -Driveway inspection pending contact development services to resolve this issue -Maintenance of erosion control Methods is Required until sod is in place -Remove excavation spoils from site -Final grade and sod per approved plot -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation -Guard rail required what a grade below exceeds 30 inches, front stoop -Label dedicated circuit in garage as non-GFCI protected -Weatherstrip front entry door
Occupancy Inspection - Codes Residential Temporary C of O 6/30/2021 6/30/2021 06/30/2021
Misc
Corrective Action Required
06/29/2021
-Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation
Sidewalk Inspection Passed 7/13/2021 7/13/2021 07/13/2021
Occupancy Inspection - Codes Residential Full C of O 9/12/2022 9/12/2022 09/12/2022
Misc
Resolved
09/12/2022
-Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation
Documents & Images
Date Uploaded File Type Document Name
10/16/2020 2342 SW Old Port Rd - Permit Application
10/16/2020 2342 SW Old Port Rd - Tax Application
10/16/2020 LOT 724 FINAL
10/16/2020 EGC724 Spec- Sealed Plans (September 18, 2020)
10/20/2020 Letter Codes Residential Plan Review
10/22/2020 Plot Plan APPROVED PLOT PLAN
10/22/2020 Plans APPROVED HOUSE PLAN
11/02/2020 Receipt Receipt for transaction:2020-007316
11/02/2020 Letter DS Building Permit
11/24/2020 Letter INSPECTION SUMMARY
11/24/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
01/11/2021 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/25/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/09/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter INSPECTION SUMMARY
06/16/2021 Letter INSPECTION SUMMARY
06/16/2021 Letter INSPECTION SUMMARY
06/16/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
06/29/2021 Letter INSPECTION SUMMARY
06/29/2021 Receipt Receipt for transaction:2021-005152
06/30/2021 Letter Codes Temporary Certificate of Occupancy
07/13/2021 Letter INSPECTION SUMMARY
09/12/2022 Letter Codes Final Certificate of Occupancy
09/12/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: