Permit Application Status

PRRES20203659


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20203659
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE - ENGINEERED FLOOR SYSTEM - ROOF TRUSS - COVERED PATIO - UNFINISHED BASEMENT
10/09/2020
10/15/2020
04/25/2022
Locations
Contacts
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
CARDINAL CREST HOMES, Address:1539 SWIFT AVE, Phone:(816) 499-3156  
JAMES@CARDINALCRESTHOMES.COM  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
JOE KILOWATT INC, Address:6506 ROYAL, Phone:(816) 792-4888  
HAMPTON PLUMBING INC, Address:P O BOX 552, Phone:(816) 628-5069  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/13/2020 10/15/2020
Dylan Eppert
Contours, spot elevations and arrows
Corrective Action Required
10/14/2020

Contours, spot elevations and drainage flow arrows (as required) shall be provided on the lot. PROVIDE CONTOURS.
Planning Review (RES) Approved 10/15/2020 10/14/2020
Dylan Eppert
Residential Plan Review Approved 10/13/2020 10/13/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,037.25 $1,037.25 Paid 10/15/2020
$0.00
8331507-Sewer Connection Fee $30.00 $30.00 Paid 10/15/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 10/15/2020
Water Meter Fee $455.54 $455.54 Paid 10/15/2020
Right of Way Permit Fee $80.00 $80.00 Paid 10/15/2020
Residential Excise Tax Fee $1,077.12 $0.00 Paid 10/13/2020
New Longview Road and Bridge Escrow $1,077.12 $1,077.12 Paid 10/15/2020
Not Ready Inspection Fee $50.00 $50.00 Paid 12/02/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 12/02/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 12/02/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 01/12/2021
Misc
Corrective Action Required
01/12/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -Immediate Street clean up required -No further inspections until resolved
Erosion Control Inspection Residential Failed 01/29/2021
Misc
Corrective Action Required
01/12/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -Immediate Street clean up required -No further inspections until resolved
Miscellaneous Inspection Failed 01/29/2021
Misc
Corrective Action Required
01/29/2021
Post site address
Sewer Service Inspection - R Passed 1/29/2021 (1:00) 1/29/2021 01/29/2021
Water Service Inspection - R Passed 1/29/2021 (1:00) 1/29/2021 01/29/2021
Misc
Corrective Action Required
01/29/2021
Water meter required to be 14-18” below pit lid
Erosion Control Inspection Residential Failed 02/04/2021
Misc
Corrective Action Required
01/29/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours or stop work order will be issued -Immediate Street clean up required -No further inspections until resolved
Miscellaneous Inspection Failed 02/04/2021
Misc
Corrective Action Required
01/29/2021
Post site address Second notification, no further inspections until site address is posted
Underslab Plumbing Inspection - Residential Failed 2/4/2021 2/4/2021 02/04/2021
Misc
Corrective Action Required
02/04/2021
Inspection denied due to lack of compliance with recent erosion control inspection reports and site address is still not posted
Footing Inspection - Residential Passed 02/09/2021
Miscellaneous Inspection Passed 02/09/2021
Misc
Resolved
02/09/2021
Post site address Second notification, no further inspections until site address is posted
Erosion Control Inspection Residential Passed 4/25/2022 02/09/2021
Misc
Resolved
02/09/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours or stop work order will be issued -Immediate Street clean up required -No further inspections until resolved
Underslab Plumbing Inspection - Residential Failed 2/9/2021 2/9/2021 02/09/2021
Misc
Resolved
02/09/2021
Inspection denied due to lack of compliance with recent erosion control inspection reports and site address is still not posted
Misc
Corrective Action Required
02/09/2021
Protect water service at concrete floor penetration
Underslab Plumbing Inspection - Residential Not Ready 2/24/2021 2/24/2021 02/24/2021
Misc
Corrective Action Required
02/09/2021
Protect water service at concrete floor penetration- provide protection from physical damage due to expansion and contraction of concrete floor
Underslab Plumbing Inspection - Residential Passed 3/3/2021 3/3/2021 03/03/2021
Misc
Resolved
03/03/2021
Protect water service at concrete floor penetration- provide protection from physical damage due to expansion and contraction of concrete floor
All Rough Inspection - Residential Failed 6/2/2021 6/2/2021 06/02/2021
Misc
Corrective Action Required
06/02/2021
-Ground metallic outlet box, exterior at garage -continue exterior fastening, portal opening at bottom plates per plan -Nail headers to king studs per code -Install truss hold down devices per plan throughout -Anchor bolts to be installed in middle third of plate -Nail plate protection at Conductor stud Penetrations throughout, locations marked -Provide stud shoe at over bored Exterior wall stud, garage at SE cable -Identify white insulated conductors to be used as current carrying conductors at both points of termination -Provide washer and nut at anchor bolt in garage corner -Top plate spices to offset minimum 24 inches. mudroom, header at entry/living room -Maintain minimum 1 inch clearance to combustible’s at gas B vent in mud room chase -Provide hangers at header floor joist above mudroom -Fireblock through floor Penetrations throughout -Complete bath exhaust duct installation -complete braced wall method CS-PF framing and fastening per plan, dining room & master bed See S-2.1 for detail -12” oc fastening, stud to stud and abutting studs at intersecting braced walls, locations marked -Complete master tub plumbing installation -Complete gas piping installation -Nail plate protection at DWV Plate Penetrations. kitchen, Bed three closet -Address Plate notches in kitchen -Protect NM conductors from physical damage minimum 6” AFF at floor penetrations -Install flashing at roof penetrations -Address damaged truss, master bed/bath wall -Interior braced walls per plan. Wall bracing required behind tub/shower second floor. Plan allows Method GB or LIB -Girder truss end bearing per plan -Minimum 12” field 6” edge exterior sheathing fastening -Tie second floor exterior wall at offset top plates in office -Finish nailing hangers above office -Finish nailing hanger, LVL to LVL connection above basement stairs -Provide joist hanger at joist to LVL connection at basement stairs -Provide hangers at header Joist by furnace -Provide full depth solid blocking at first floor cantilevered section -Provide safety glazed windows at landings between stairs where stair forward motion is towards exterior wall -Comply with fire separation distance requirements per table R302.1(1) for projections, see footnote A
Gas Service Inspection - Residential Failed 6/2/2021 6/2/2021 06/02/2021
Misc
Corrective Action Required
06/02/2021
Install and pressure test gas piping
Electrical Service Inspection Passed 6/2/2021 6/2/2021 06/02/2021
Gas Service Inspection - Residential Passed 6/10/2021 6/10/2021 06/10/2021
Misc
Resolved
06/10/2021
All Rough Inspection - Residential Failed 6/18/2021 6/18/2021 06/18/2021
Misc
Corrective Action Required
06/02/2021
-Install truss hold down devices per plan throughout, Second-floor laundry -Top plate spices to offset minimum 24 inches. mudroom and header at entry/living room -Maintain minimum 1 inch clearance to combustible’s at gas B vent in mud room chase. B vent touching PVC DWV -Fireblock through floor Penetrations throughout, locations marked -complete braced wall method CS-PF framing and fastening per plan, dining room & master bed See S-2.1 for detail -Complete master tub plumbing installation -Nail plate protection at DWV Plate Penetrations. kitchen, Bed three closet -Address Plate notches in kitchen, provide structural straps -Install flashing at roof penetrations -Address damaged truss, master bed/bath wall. Next to master bed entry door -Properly fasten metal straps used as interior wall bracing, second-floor bath behind shower/tub -Girder truss bearing per plan, second story office -Minimum 12” field 6” edge exterior sheathing fastening -Finish nailing hangers above office
All Rough Inspection - Residential Not Ready 6/28/2021 6/28/2021 06/28/2021
Misc
Corrective Action Required
06/18/2021
-Install truss hold down devices per plan, Second-floor laundry -Top plate spices to offset minimum 24 inches, mudroom exterior wall by chase -Maintain minimum 1 inch clearance to combustible’s at gas B vent in mud room chase. B vent touching PVC DWV -complete braced wall method CS-PF framing and fastening per plan, dining room & master bed See S-2.1 for detail -Complete master tub plumbing installation -Nail plate protection at DWV Plate Penetrations. Kitchen/dining -Address damaged truss, master bed/bath wall. Next to master bed entry door. Engineered documentation required for field repairs -Address hanging electrical conductor in master bed. -Properly fasten metal straps used as interior wall bracing, second-floor bath behind shower/tub -Girder truss bearing per plan, second story office -Minimum 12” field 6” edge exterior sheathing fastening -Finish nailing hangers above office
All Rough Inspection - Residential Not Ready 7/7/2021 7/7/2021 07/07/2021
Misc
Corrective Action Required
06/28/2021
-Top plate spices to offset minimum 24 inches, mudroom exterior wall by chase ,, painted but incomplete. -Maintain minimum 1 inch clearance to combustible’s at gas B vent in mud room chase. B vent touching PVC DWV, now fire stop the holes in the floor. -complete braced wall method CS-PF framing and fastening per plan, dining room & master bed See S-2.1 for detail -Address damaged truss, master bed/bath wall. Next to master bed entry door. Engineered documentation required for field repairs -Properly fasten metal straps used as interior wall bracing, second-floor bath behind shower/tub, incomplete. B vent damaged behind shower at elbow… replace. office. -Finish nailing hangers above office incomplete,,
Erosion Control Inspection Residential Failed 7/7/2021 07/07/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/07/2021
OVER GROWN VEGETATION, CUT BELOW 10" AS PER ORDINANCE.
All Rough Inspection - Residential Failed 7/8/2021 7/8/2021 07/08/2021
Misc
Corrective Action Required
07/07/2021
-Address damaged truss, master bed/bath wall. Next to master bed entry door. Engineered documentation required for field repairs, i dont see a repair report?? -Properly fasten metal straps used as interior wall bracing, second-floor bath behind shower/tub, incomplete.,,,, revised plans show sheet rock on both sides, will have to remove tub and install rock or revise plans showing only one side. B vent damaged behind shower at elbow… replace. ---office : one joist hanger in the office to the truss is missing nails.
Sidewalk Inspection Partial 11/29/2021 11/29/2021 11/29/2021
Misc
Informational
11/29/2021
Sidewalk is framed up and has aggregate in place and compacted. 11/29 ES
Sidewalk Inspection Passed 12/3/2021 12/3/2021 12/03/2021
Misc
Informational
11/29/2021
Sidewalk is framed up and has aggregate in place and compacted. 11/29 ES
Misc
Informational
12/03/2021
Finished sidewalk meets LS and ADA specs. RP 12-3-21
All Rough Inspection - Residential Passed 12/15/2021
Misc
Resolved
12/15/2021
-Address damaged truss, master bed/bath wall. Next to master bed entry door. Engineered documentation required for field repairs, i dont see a repair report?? -Properly fasten metal straps used as interior wall bracing, second-floor bath behind shower/tub, incomplete.,,,, revised plans show sheet rock on both sides, will have to remove tub and install rock or revise plans showing only one side. B vent damaged behind shower at elbow… replace. ---office : one joist hanger in the office to the truss is missing nails.
Occupancy Inspection - Codes Residential Temporary C of O 12/15/2021 12/15/2021 12/15/2021
Misc
Corrective Action Required
12/15/2021
- obtain sprinkler permit and submit back flow certification - Splash blocks - Final grading and sod
Plot Plan Inspection Passed 04/25/2022
Erosion Control Inspection Residential Passed 4/25/2022 04/25/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/25/2022
Occupancy Inspection - Codes Residential Full C of O 4/26/2022 4/25/2022 04/25/2022
Misc
Resolved
04/25/2022
Documents & Images
Date Uploaded File Type Document Name
10/09/2020 Application Form Lot 94 Permit App
10/09/2020 SCOUT 3 BED SPEC (PP) - Staked Plot Plan
10/09/2020 SCOUT 3 BED SPEC (PP) - Engineered Plans (ANSI D)
10/12/2020 License Tax Form
10/14/2020 Letter Codes Residential Plan Review
10/15/2020 Plot Plan APPROVED PLOT PLAN
10/15/2020 Plans APPROVED HOUSE PLAN
10/15/2020 Receipt Receipt for transaction:2020-006958
10/15/2020 Letter DS Building Permit
12/14/2020 Specifications APPROVED ROOF TRUSS PACKAGE
12/14/2020 Plans APPROVED REVISED HOUSE PLAN
12/14/2020 Drawing APPROVED ROOF TRUSS LAYOUT
12/14/2020 Drawing APPROVED 1ST FLOOR STICK ROOF LAYOUT
12/14/2020 Drawing APPROVED 1ST FLOOR JOIST LAYOUT
12/14/2020 Drawing APPROVED 2ND FLOOR JOIST LAYOUT
01/12/2021 Letter INSPECTION SUMMARY
01/15/2021 1036 SW Armie LSMO Pergola Park Lot 94 3rd Party Footing Inspection Report
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/09/2021 Letter INSPECTION SUMMARY
02/09/2021 Letter INSPECTION SUMMARY
02/09/2021 Letter INSPECTION SUMMARY
02/09/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
03/03/2021 Letter INSPECTION SUMMARY
03/08/2021 Final_2021_03_04_GSlab Stoop_LSMO_Cardinal Crest
06/02/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/10/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/28/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/12/2021 Approved Plans Approved Revised Truss Package
07/19/2021 DW Structural Recommendation Letter Scout 3 Bdrm Spec 1036 SW Armie St
11/29/2021 Letter INSPECTION SUMMARY
12/02/2021 Receipt Receipt for transaction:2021-009056
12/03/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter Codes Temporary Certificate of Occupancy
03/15/2022 1036 SW Armie St (Sprinkler Release)
04/25/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter Codes Final Certificate of Occupancy
04/25/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home