Permit Application Status

PRRES20203584


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20203584
Building Permit - Residential
Certificate of Occupancy
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED AND FINISHED BASEMENT (sheetrock only) - COVERED PATIO
10/07/2020
10/14/2020
04/06/2021
02/16/2023
Locations
Contacts
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC, Address:13450 E STATE ROUTE 150  
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
BMW ELECTRIC CO, Address:1238 W 31ST, Phone:(816) 289-3474  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
WOODBROTHERSINC.GMAILCOM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 10/14/2020 10/12/2020
Kim Brennan
Misc
Corrective Action Required
10/12/2020

Missing rear, left and right side elevations
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
10/12/2020

Identify roof covering material (IRC Section R905)
Plot Plan Review Approved 10/14/2020 10/12/2020
Kim Brennan
Plot Plan Review Approved 10/09/2020 10/09/2020
Kim Brennan
Deck location
Corrective Action Required
10/08/2020

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered patio
Residential Plan Review Rejected 10/09/2020 10/07/2020
Kim Brennan
Misc
Corrective Action Required
10/07/2020

Missing rear, left and right side elevations
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
10/07/2020

Identify roof covering material (IRC Section R905)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,277.42 $1,277.42 Paid 10/14/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/14/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/14/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 10/14/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 10/14/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 10/14/2020
9110078-Additional Permit Fee $109.48 $109.48 Paid 09/09/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 01/12/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/17/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/28/2021 7/28/2021 07/28/2021
Misc
Informational
07/28/2021
APPROVED PER DAVID AINSWORTH 7/27/21
Underslab Plumbing Inspection - Residential Failed 8/26/2021 8/26/2021 08/26/2021
Misc
Corrective Action Required
08/26/2021
UNABLE TO PERFORM INSPECTION, BASEMENT UNDERSLAB COMPLETELY SUBMERGED IN WATER AND DWV FLOATED. PUMP OUT WATER OR WAIT FOR CONDITIONS TO IMPROVE BEFORE RESCHEDULING
Underslab Plumbing Inspection - Residential Passed 9/22/2021 9/22/2021 09/22/2021
Misc
Resolved
09/22/2021
All Rough Inspection - Residential Failed 11/11/2021 11/11/2021 11/11/2021
Misc
Corrective Action Required
11/11/2021
NO INSPECTION PERFORMED, HOUSE NOT READY FOR ALL ROUGH, HOUSE HAS NOT BEEN FRAMED YET
Piers/Caissons Inspection - Residential Failed 11/19/2021 (1:00) 11/19/2021 11/19/2021
Misc
Corrective Action Required
11/19/2021
Piers not per plans.
Piers/Caissons Inspection - Residential Passed 11/23/2021 (10:00) 11/23/2021 11/23/2021
Misc
Resolved
11/23/2021
Piers not per plans.
Miscellaneous Inspection Passed 4/21/2022 04/21/2022
Misc
Informational
04/21/2022
spoke wth jud who requested a permit extension
Gas Service Inspection - Residential Passed 5/5/2022 5/5/2022 05/05/2022
Erosion Control Inspection Residential Failed 5/5/2022 05/05/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/05/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. REPAIR SILT FENCE
Electrical Service Inspection Failed 5/5/2022 5/5/2022 05/05/2022
Miscellaneous Correction
Corrective Action Required
05/05/2022
Provide #4 jumper from grounding bus to neutral bus bar
All Rough Inspection - Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Resolved
05/05/2022
NO INSPECTION PERFORMED, HOUSE NOT READY FOR ALL ROUGH, HOUSE HAS NOT BEEN FRAMED YET
Miscellaneous Correction
Corrective Action Required
05/05/2022
No plans on sight Inspection denied
Electrical Service Inspection Failed 5/31/2022 5/31/2022 05/31/2022
Miscellaneous Correction
Corrective Action Required
05/05/2022
Provide #4 jumper from grounding bus to neutral bus bar 5/31/222 no change
All Rough Inspection - Residential Failed 5/31/2022 5/31/2022 05/31/2022
Miscellaneous Correction
Resolved
05/31/2022
No plans on sight Inspection denied
Miscellaneous Correction
Corrective Action Required
05/31/2022
- Anchor bolt with in 12” of plate break at garage single bay - Straps on PFH portal frame should include the top plate on a double plate setup - Fire block penetration in return air at mud room - Security blocking at sliding door main floor - Fire block return air office near stairs - Provide joist hangers on joist over 4’ in dining room at I beam - Address hip rafter landing on block master closet at shower chase - Address damaged stud bedroom 4 at hall - Fire block penetration in cripple wall to attic space bedroom 4 at foyer - Fire block penetration top plate bedroom 2 exterior wall - Strap DWV 2” and under bedroom 2 bathroom at tub - Provide anchor bolt stairs landing, plate beak - 4 of 5 columns are to be 3 1/2” , currently all are 3”
All Rough Inspection - Residential Failed 6/7/2022 6/7/2022 06/07/2022
Miscellaneous Correction
Corrective Action Required
05/31/2022
- Address hip rafter landing on block master closet at shower chase Okay to insulate
Electrical Service Inspection Passed 6/7/2022 06/07/2022
Miscellaneous Correction
Corrective Action Required
05/31/2022
Provide #4 jumper from grounding bus to neutral bus bar 5/31/222 no change
All Rough Inspection - Residential Passed 6/30/2022 6/30/2022 06/30/2022
Miscellaneous Correction
Resolved
06/30/2022
Sewer Service Inspection - R Failed 8/8/2022 (1:45) 8/8/2022 08/08/2022
Misc
Corrective Action Required
08/08/2022
missing tracer wire
Water Service Inspection - R Passed 8/12/2022 (10:00) 8/10/2022 08/10/2022
Sewer Service Inspection - R Passed 8/10/2022 (10:00) 8/10/2022 08/10/2022
Misc
Resolved
08/10/2022
missing tracer wire
Driveway Inspection Partial 8/30/2022 8/30/2022 08/30/2022
Misc
Informational
08/30/2022
8-30-22 RH. Driveway is formed up and aggregate is placed and compacted.
Driveway Inspection Partial 9/6/2022 9/6/2022 09/06/2022
Misc
Informational
08/30/2022
8-30-22 RH. Driveway is formed up and aggregate is placed and compacted. 9-6-22 RH. Driveway meets LS specification.
Driveway Inspection Passed 9/6/2022 09/06/2022
Misc
Informational
09/06/2022
8-30-22 RH. Driveway is formed up and aggregate is placed and compacted. 9-6-22 RH. Driveway meets LS specification.
All Rough Inspection - Residential Failed 10/4/2022 10/04/2022
Misc
Corrective Action Required
10/04/2022
inspection denied erosion control not in compliance
Erosion Control Inspection Residential Failed 10/4/2022 10/04/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/04/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. REPAIR SILT FENCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/04/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 10/20/2022 10/20/2022 10/20/2022
Misc
Resolved
10/20/2022
inspection denied erosion control not in compliance
Misc
Corrective Action Required
10/20/2022
-provide support for furr down ceiling joists in basement -seal dead space at basement bath and shower -rock or pan R/a in office
Sidewalk Inspection Partial 10/21/2022 10/21/2022 10/21/2022
Misc
Informational
10/21/2022
Sidewalk has been formed and rock is installed but needs to be compacted. The forms appear to be ADA compliant at this time. I also asked the contractor to clean up the dirt and rock that is in the street due to the forming up of the sidewalk.
All Rough Inspection - Residential Passed 10/27/2022 10/27/2022 10/27/2022
Misc
Resolved
10/27/2022
-provide support for furr down ceiling joists in basement -seal dead space at basement bath and shower -rock or pan R/a in office
Sidewalk Inspection Passed 11/2/2022 11/02/2022
Misc
Informational
10/21/2022
Sidewalk has been formed and rock is installed but needs to be compacted. The forms appear to be ADA compliant at this time. I also asked the contractor to clean up the dirt and rock that is in the street due to the forming up of the sidewalk. 11-2-22 RH. Sidewalk meets LS and ADA specification.
Occupancy Inspection - Codes Residential Failed 1/13/2023 1/13/2023 01/13/2023
Misc
Corrective Action Required
01/13/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation -water meter to be 14”-18” from top of meter to meter well lid -front entry steps greater than 3/8 difference in rise -wall switch for lighting in sump pump room and under suspended slab room. E3903.4 IRC -handrail in garage grip size to comply with code section R311.7.8.5 of the IRC -address siding from ground at rear patio
Occupancy Inspection - Codes Residential Ready for Temp CO 1/17/2023 1/17/2023 01/17/2023
Misc
Corrective Action Required
01/13/2023
-sod -front entry steps greater than 3/8 difference in rise
Occupancy Inspection - Codes Residential Full C of O 2/16/2023 02/16/2023
Misc
Resolved
02/16/2023
-sod -front entry steps greater than 3/8 difference in rise
Documents & Images
Date Uploaded File Type Document Name
10/07/2020 Application Form Permit Application
10/07/2020 Application Form License Tax Application
10/07/2020 DW Permit Plan Arybella II Lot 60 Summit View Farms 3126 SW Blue Ribbon St
10/08/2020 Letter Codes Residential Plan Review
10/09/2020 Plot Plan Approved Plot Plan
10/14/2020 Receipt Receipt for transaction:2020-006931
10/14/2020 Letter DS Building Permit
10/15/2020 Approved Plans Approved Drawings
07/28/2021 M L Crose 3126 SW Blue Ribbon St LSMO Permit 2020-3584 Footing Inspection Report 7-27-21
07/28/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
04/19/2022 Letter Codes 140 Day Letter
04/21/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/29/2022 DW INSPECTION LETTER Arybella II Lot 60 Summit View Farms 3126 SW Blue Ribbon Street 6-29-22
06/30/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/09/2022 Basement permit application 3126
09/09/2022 Approved Plans APPROVED BASEMENT FINISH
09/09/2022 Receipt Receipt for transaction:2022-007416
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/20/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
01/12/2023 Receipt Receipt for transaction:2023-000207
01/13/2023 Letter INSPECTION SUMMARY
01/17/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/17/2023 Receipt Receipt for transaction:2023-000288
02/16/2023 Letter Field Certificate of Occupancy
02/16/2023 Letter Codes Final Certificate of Occupancy
02/22/2023 Extension Request Form filled out
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home