Permit Application Status

PRRES20203580


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20203580
Building Permit - Residential
Certificate of Occupancy
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 03/29/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 04/28/2022 12:00 AM by username 'Mitchell Schwarz'.
10/07/2020
10/15/2020
10/04/2022
Locations
Contacts
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC, Address:13450 E STATE ROUTE 150  
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
WOODBROTHERSINC@GMAIL.COM  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
BMW ELECTRIC CO, Address:1238 W 31ST, Phone:(816) 289-3474  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/09/2020 10/15/2020
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
10/09/2020

LABEL COVERED DECK
As-graded plot plan
Corrective Action Required
10/09/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 10/09/2020 10/15/2020
Dylan Eppert
Misc
Corrective Action Required
10/09/2020

HOUSE PLANS MUST MATCH IT APPEARS THE GARAGE IS FLIPPED.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
10/09/2020

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) MISSING IN THE BEDROOMS ON THE MAIN FLOOR
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
10/09/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) MISSING IN ALL THE BEDROOMS.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,116.41 $1,116.41 Paid 10/15/2020
8331507-Sewer Connection Fee $420.00 $420.00 Paid 10/15/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 10/15/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 10/15/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/15/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/15/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/14/2020 (9:00) 12/14/2020 12/14/2020
Underslab Plumbing Inspection - Residential Failed 1/27/2021 1/27/2021 01/27/2021
Misc
Corrective Action Required
01/27/2021
-UNABLE TO INSPECT DWV DUE TO SNOW COVER. RESCHEDULE WHEN CONDITIONS ALLOW FOR FULL INSPECTION
Underslab Plumbing Inspection - Residential Passed 1/29/2021 1/29/2021 01/29/2021
Misc
Resolved
01/29/2021
-UNABLE TO INSPECT DWV DUE TO SNOW COVER. RESCHEDULE WHEN CONDITIONS ALLOW FOR FULL INSPECTION
Piers/Caissons Inspection - Residential Passed 3/3/2021 (1:15) 3/3/2021 03/03/2021
Erosion Control Inspection Residential Failed 5/27/2021 5/27/2021 05/27/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/27/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. MAINTAIN EROSION CONTROL ON LOT
Erosion Control Inspection Residential Failed 6/25/2021 6/25/2021 06/25/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/25/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/25/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. CLEAN ALL MUD AND GRAVEL FROM STREET
Erosion Control Inspection Residential Failed 7/2/2021 7/2/2021 07/02/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/25/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. CLEAN ALL MUD AND GRAVEL FROM STREET
Electrical Service Inspection Passed 9/3/2021 9/3/2021 09/03/2021
Gas Service Inspection - Residential Passed 9/3/2021 9/3/2021 09/03/2021
All Rough Inspection - Residential Failed 9/3/2021 9/3/2021 09/03/2021
Misc
Corrective Action Required
09/03/2021
-No inspection performed on suspended slab -Add protection bocca plates at top and bottom plate, structural straps at top plate at DWV garage wall and terminate vent to exterior -secure all vertical DWV 2” or less at mid point -Add joist hanger to sgl joist beam connection master bed, over 4’ -pan off attic at fireplace 1st floor -Protect NM at kitchen island floor penetration 6” AFF -scrape off paint to allow for contact and ground metal ceiling plate above front entry -(3) 1 3/4” x 18” lvl ridge at great room per plans -add joist hangers at ceiling joists over 4’ great room -Unable to covered deck and front porch construction with cover -Secure/Support all NM every 4.5’ through furred downs in basement -Fireblock all tub and shower traps -Ensure UFER ground remains accessible at finish -Solid block between joists at cantilevers -Seal all penetrations through air returns-See finished basement -CSST ward flex gas shall not be less than 3” from end of joist when bored through joist -Min (1) electrical receptacle required in safe room -Nail all exterior sheathing per plans, unable to confirm nailing with sheathing having been painted prior to inspection -PFG portal frame per design -Scrape paint underneath gas line binding clamp on exterior so that clamp is making contact with metal pipe **DO NOT INSULATE**
Sewer Service Inspection - R Partial 9/16/2021 (2:00) 9/16/2021 09/16/2021
Misc
Informational
09/16/2021
PARTIAL ON WASTE FROM NORTH SIDE OF HOUSE TO 8' ACROSS FRONT PORCH
Water Service Inspection - R Partial 9/16/2021 (2:00) 9/16/2021 09/16/2021
Misc
Informational
09/16/2021
PARTIAL ON COPPER FROM TAP TO END OF 10' TAIL, DOUBLE CHECK METER TO LID HEIGHT AT REINSPECT
Sewer Service Inspection - R Passed 9/17/2021 9/17/2021 09/17/2021
Misc
Resolved
09/17/2021
Water Service Inspection - R Passed 9/17/2021 (11:30) 9/17/2021 09/17/2021
Misc
Resolved
09/17/2021
All Rough Inspection - Residential Failed 11/15/2021 11/15/2021 11/15/2021
Misc
Corrective Action Required
09/03/2021
-No inspection performed on suspended slab -Add protection bocca plates at top and bottom plate, structural straps at top plate at DWV garage wall and terminate vent to exterior -secure all vertical DWV 2” or less at mid point -Protect NM at kitchen island floor penetration 6” AFF -scrape off paint to allow for contact and ground metal ceiling plate above front entry -(3) 1 3/4” x 18” lvl ridge at great room per plans -Unable to covered deck and front porch construction with cover -Secure/Support all NM every 4.5’ through furred downs in basement -Ensure UFER ground remains accessible at finish -Solid block between joists at cantilevers -Seal all penetrations through air returns-See finished basement -Min (1) electrical receptacle required in safe room -Nail all exterior sheathing per plans, unable to confirm nailing with sheathing having been painted prior to inspection -PFG portal frame per design -Scrape paint underneath gas line binding clamp on exterior so that clamp is making contact with metal pipe **DO NOT INSULATE**
Driveway Inspection Passed 12/14/2021 12/14/2021 12/16/2021
Misc
Informational
12/14/2021
On Tuesday 12.14.2021 I performed a driveway inspection and pass the subgrade to pour concrete
All Rough Inspection - Residential Passed 12/17/2021 12/17/2021 12/17/2021
Misc
Resolved
12/17/2021
Erosion Control Inspection Residential Failed 3/16/2022 03/16/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
03/16/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. CLEAN ALL MUD AND GRAVEL FROM STREET
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/16/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
03/29/2022
Erosion control still not in compliance Mitchell Schwarz 03/29/2022 3:07 PM
Erosion Control Inspection Residential Failed - Stop Work 3/29/2022 03/29/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/16/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
03/29/2022
Erosion control still not in compliance Mitchell Schwarz 03/29/2022 3:11 PM
Erosion Control Inspection Residential Partial 4/28/2022 4/28/2022 04/28/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
04/28/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
04/28/2022
Erosion control still not in compliance Mitchell Schwarz 03/29/2022 3:11 PM
Misc
Informational
04/28/2022
Erosion control back in compliance provide premises identification
Sidewalk Inspection Passed 4/28/2022 4/28/2022 04/28/2022
Occupancy Inspection - Codes Residential Failed 5/5/2022 5/5/2022 05/05/2022
Miscellaneous Correction
Corrective Action Required
05/05/2022
List incomplete, stopping inspection due to missing stair spindles - final grading and sod - Label all non GFCI outlets - Garage entry door must be self closing and latch
Plot Plan Inspection Passed 5/5/2022 05/05/2022
Occupancy Inspection - Codes Residential Failed 5/9/2022 5/9/2022 05/09/2022
Miscellaneous Correction
Corrective Action Required
05/05/2022
Address stairs not compliant with code section r311.7.5.1 (see top step) -lock out for hot water heater -tamper resistant caps at A/c unit -guard rail at front stoop where more than 30" from grade 36" out
Occupancy Inspection - Codes Residential Failed 5/9/2022 05/09/2022
Miscellaneous Correction
Corrective Action Required
05/09/2022
Address stairs not compliant with code section r311.7.5.1 (see top step) -lock out for hot water heater -tamper resistant caps at A/c unit -guard rail at front stoop where more than 30" from grade 36" out
Occupancy Inspection - Codes Residential Temporary C of O 5/9/2022 05/09/2022
Miscellaneous Correction
Corrective Action Required
05/09/2022
TCO issued until 5/23/22 Based on the fact that the builder submitted a CMR for the stair issue on 5/9/22 a TCO will be granted for 2 weeks. Prior to the end of the 2 weeks the builder needs to re-schedule the final inspection and be present at the time of the inspection. CMR is still pending and waiting review. In the event the CMR is not approved this gives the builder 2 weeks to make needed repairs by 5/23/22. Address stairs not compliant with code section r311.7.5.1 (see top step) -lock out for hot water heater breaker -tamper resistant caps at A/c unit -guard rail at front stoop where more than 30" from grade 36" out
Occupancy Inspection - Codes Residential Temporary C of O 5/31/2022 5/31/2022 05/31/2022
Miscellaneous Correction
Corrective Action Required
05/09/2022
TCO issued until 5/23/22 Based on the fact that the builder submitted a CMR for the stair issue on 5/9/22 a TCO will be granted for 2 weeks. Prior to the end of the 2 weeks the builder needs to re-schedule the final inspection and be present at the time of the inspection. CMR is still pending and waiting review. In the event the CMR is not approved this gives the builder 2 weeks to make needed repairs by 5/23/22. 5/31/22 lock out and stairs now complient. outide items not complete. -tamper resistant caps at A/c unit -guard rail at front stoop where more than 30" from grade 36" out
Erosion Control Inspection Residential Passed 10/4/2022 10/04/2022
Misc
Resolved
10/04/2022
Erosion control back in compliance provide premises identification
Occupancy Inspection - Codes Residential Full C of O 10/4/2022 10/4/2022 10/04/2022
Miscellaneous Correction
Resolved
10/04/2022
TCO issued until 5/23/22 Based on the fact that the builder submitted a CMR for the stair issue on 5/9/22 a TCO will be granted for 2 weeks. Prior to the end of the 2 weeks the builder needs to re-schedule the final inspection and be present at the time of the inspection. CMR is still pending and waiting review. In the event the CMR is not approved this gives the builder 2 weeks to make needed repairs by 5/23/22. 5/31/22 lock out and stairs now complient. outide items not complete. -tamper resistant caps at A/c unit -guard rail at front stoop where more than 30" from grade 36" out
Documents & Images
Date Uploaded File Type Document Name
10/07/2020 Signed Excise tax application
10/07/2020 Signed permit application
10/07/2020 LOT 54 FINAL plot plan
10/07/2020 DW Permit Plan The Aspen Ranch 3117 SW Blue Ribbon St Summit View Farms (2)
10/09/2020 Letter Codes Residential Plan Review
10/13/2020 Plot Plan APPROVED PLOT PLAN
10/15/2020 Plans APPROVED HOUSE PLANS
10/15/2020 Receipt Receipt for transaction:2020-006974
10/15/2020 Letter DS Building Permit
12/14/2020 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
03/03/2021 Letter INSPECTION SUMMARY
05/27/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
11/03/2021 DW Framing Inspection Report The Aspen Ranch 3117 SW Blue Ribbon St SVF
11/18/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter Stop Work Order
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
05/04/2022 deck framing
05/04/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter Codes Temporary Certificate of Occupancy
05/31/2022 Letter Codes Temporary Certificate of Occupancy
10/04/2022 Letter Codes Final Certificate of Occupancy
10/04/2022 Letter Field Certificate of Occupancy
10/04/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home