Summary
PRRES20202946
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
09/11/2020
09/16/2020
09/30/2022
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/16/2020 09/16/2020
Kim Brennan
As-graded plot plan
Corrective Action Required
09/14/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 09/16/2020 09/14/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $997.22 $997.22 Paid 09/16/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/16/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/16/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 09/16/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 09/16/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 09/16/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 07/21/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 07/21/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/28/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/30/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/8/2020 (11:30) 10/8/2020 10/08/2020
Erosion Control Inspection Residential Passed 10/8/2020 10/08/2020
Underslab Plumbing Inspection - Residential Failed 11/24/2020 11/24/2020 11/24/2020
Misc
Corrective Action Required
11/24/2020
Complete interior underslab drain tile with positive or neutral slope and connect to sump pit
Underslab Plumbing Inspection - Residential Passed 12/1/2020 12/1/2020 12/01/2020
Misc
Resolved
12/01/2020
Complete interior underslab drain tile with positive or neutral slope and connect to sump pit
Sewer Service Inspection - R Passed 10/11/2021 01/11/2021
Water Service Inspection - R Passed 1/13/2021 01/13/2021
Erosion Control Inspection Residential Failed 2/3/2021 02/03/2021
Misc
Corrective Action Required
02/03/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -remove debris from curb/gutter -no further inspections until issues are resolved
All Rough Inspection - Residential Failed 3/10/2021 3/10/2021 03/10/2021
Misc
Corrective Action Required
03/10/2021
Portal frame -Two rows of 16D sinker nails 3” oc at braced wall panel top plates per plan, see section view of detail
All Rough Inspection - Residential Partial 3/19/2021 3/19/2021 03/19/2021
Misc
Informational
03/19/2021
Portal frame approved
Piers/Caissons Inspection - Residential Passed 3/29/2021 (9:00) 3/29/2021 03/29/2021
All Rough Inspection - Residential Failed 4/9/2021 4/9/2021 04/09/2021
Misc
Informational
03/19/2021
Portal frame approved 04/09/2021 Electrical contractors on site, not ready for inspection
All Rough Inspection - Residential Failed 4/16/2021 4/16/2021 04/16/2021
Misc
Informational
04/09/2021
-Inadequate fireblock bottom plate Penetration in Garage -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Strap noncontinuous studs at gable in wall, bedroom 3 -Provide engineered solution for rafters sitting on blocks throughout out -Fireblock bottom plate Penetration, bedroom two -fireblock bottom plate Penetrations, bathroom at front entry -Repair damaged fireblock bathroom wall at entry -fireblock bottom plate Penetration in kitchen -Fireblock through floor Penetrations -Inadequate fireblock at top plate Penetration, 2 x 6 living room exterior wall -Secure CSST at fireplace -Provide safety glazed window, master bedroom -Tighten anchor bolts throughout -Provide anchor bolts both sides of basement window -Provide engineer report regarding cracked foundation wall, west side -Pressure test gas piping minimum 10 psi for 15 minutes -Missing column under beam in basement -Address triple 2 x 12 beam in master bedroom bearing on wood fire block -Deck ledger connection to structure per code -Provide bearing support for outer deck Joists -Provide receptacle within 25 feet of exterior HVAC equipment
Gas Piping Inspection - Residential Failed 4/16/2021 4/16/2021 04/16/2021
Misc
Corrective Action Required
04/16/2021
-secure CSST at fire place -pressure test gas piping
Gas Service Inspection - Residential Failed 4/16/2021 4/16/2021 04/16/2021
Electrical Service Inspection Passed 4/16/2021 4/16/2021 04/16/2021
Misc
Resolved
04/16/2021
-Inadequate fireblock bottom plate Penetration in Garage -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Strap noncontinuous studs at gable in wall, bedroom 3 -Provide engineered solution for rafters sitting on blocks throughout out -Fireblock bottom plate Penetration, bedroom two -fireblock bottom plate Penetrations, bathroom at front entry -Repair damaged fireblock bathroom wall at entry -fireblock bottom plate Penetration in kitchen -Fireblock through floor Penetrations -Inadequate fireblock at top plate Penetration, 2 x 6 living room exterior wall -Secure CSST at fireplace -Provide safety glazed window, master bedroom -Tighten anchor bolts throughout -Provide anchor bolts both sides of basement window -Provide engineer report regarding cracked foundation wall, west side -Pressure test gas piping minimum 10 psi for 15 minutes -Missing column under beam in basement -Address triple 2 x 12 beam in master bedroom bearing on wood fire block -Deck ledger connection to structure per code -Provide bearing support for outer deck Joists -Provide receptacle within 25 feet of exterior HVAC equipment
Erosion Control Inspection Residential Failed 4/16/2021 04/16/2021
Misc
Corrective Action Required
02/03/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -remove debris from curb/gutter -no further inspections until issues are resolved
Electrical Service Inspection Passed 4/21/2021 4/21/2021 04/21/2021
Misc
Resolved
04/21/2021
-Inadequate fireblock bottom plate Penetration in Garage -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Strap noncontinuous studs at gable in wall, bedroom 3 -Provide engineered solution for rafters sitting on blocks throughout out -Fireblock bottom plate Penetration, bedroom two -fireblock bottom plate Penetrations, bathroom at front entry -Repair damaged fireblock bathroom wall at entry -fireblock bottom plate Penetration in kitchen -Fireblock through floor Penetrations -Inadequate fireblock at top plate Penetration, 2 x 6 living room exterior wall -Secure CSST at fireplace -Provide safety glazed window, master bedroom -Tighten anchor bolts throughout -Provide anchor bolts both sides of basement window -Provide engineer report regarding cracked foundation wall, west side -Pressure test gas piping minimum 10 psi for 15 minutes -Missing column under beam in basement -Address triple 2 x 12 beam in master bedroom bearing on wood fire block -Deck ledger connection to structure per code -Provide bearing support for outer deck Joists -Provide receptacle within 25 feet of exterior HVAC equipment
All Rough Inspection - Residential Failed 4/21/2021 4/21/2021 04/21/2021
Misc
Corrective Action Required
04/21/2021
-12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Strap noncontinuous studs at gable in wall, bedroom 3 -Provide engineered solution for rafters sitting on blocks throughout out -Inadequate fireblock at bottom plate Penetrations in kitchen exterior wall (2) -Fireblock through floor Penetration, kitchen -Provide safety glazed window, master bedroom -Tighten anchor bolts throughout -Provide anchor bolts both sides of basement window -Provide engineer report regarding cracked foundation wall, west side -Missing column under beam in basement -Address triple 2 x 12 beam in master bedroom bearing on wood fire block -Deck ledger connection to structure per code -Provide bearing support for outer deck Joists
Gas Piping Inspection - Residential Passed 4/21/2021 4/21/2021 04/21/2021
Misc
Resolved
04/21/2021
Gas Service Inspection - Residential Passed 4/21/2021 4/21/2021 04/21/2021
All Rough Inspection - Residential Failed 4/26/2021 4/26/2021 04/26/2021
Misc
Corrective Action Required
04/21/2021
-Fireblock through floor Penetration, kitchen -Provide safety glazed window, master bedroom -Tighten anchor bolts throughout, Right of basement window & garage -Provide engineer report regarding cracked foundation wall, west side
All Rough Inspection - Residential Failed 4/30/2021 4/30/2021 04/30/2021
Misc
Corrective Action Required
04/26/2021
-Fireblock through floor Penetration, kitchen -Provide safety glazed window, master bedroom -Provide engineer report regarding cracked foundation wall, west side Ok to insulate
Driveway Inspection Passed 6/22/2021 6/22/2021 06/22/2021
Erosion Control Inspection Residential Failed 7/21/2021 07/27/2021
Misc
Corrective Action Required
04/16/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -Restore silt fence at front of lot and remove debris from site and street
Plot Plan Inspection Failed 7/27/2021 07/27/2021
Misc
Corrective Action Required
07/27/2021
7-27-2021 -Site not ready for plot plan inspection -Complete final grade, remove debris and resubmit elevations when complete
Occupancy Inspection - Codes Residential Failed 7/28/2021 7/28/2021 07/28/2021
Miscellaneous Correction
Corrective Action Required
07/28/2021
7-28-21 -INSPECTION DENIED DUE TO LACK OF EROSION CONTROL-SEE FAILED EROSION CONTROL INSPECTION ON 7-27-21 -PROVIDE PROPER EROSION CONTROL AND CLEAN DEBRIS FROM STREET BEFORE RESCHEDULING
Occupancy Inspection - Codes Residential Failed 8/4/2021 8/4/2021 08/04/2021
Miscellaneous Correction
Corrective Action Required
07/28/2021
**8-4-21 -PROVIDE EROSION CONTROL AT BACK OF LOT-PROTECT SWALE AND FIELD INLET-REQUIRED UNTIL SOD IS IN PLACE. NO RE INSTPECTION UNTIL ISSUE IS CORRECTED -FINAL GRADE AND SOD -SPLASH BLOCKS AND SUMP EXTENSION -PROVIDE (2) 3" SCREWS AT EACH HINGE AND STRIKE PLATE -ADJUST GARAGE DOOR TO SELF CLOSE AND LATCH -SEAL GARAGE FLOOR AT BEAM POCKET -SECURE HANDRAIL AT BASEMENT STEPS -SECURE AND SUPPORT HANDRAIL AT DECK TO RESIST 200 LBS -MAX BREAKER AT AC TO BE 40 AMPS -ALL ROUGH INSPECTION NOT PASSED-ADDRESS ALL ITEMS
Occupancy Inspection - Codes Residential Failed 8/6/2021 8/6/2021 08/06/2021
Miscellaneous Correction
Corrective Action Required
08/04/2021
-MAINTAIN EROSION CONTROL AND PROTECT SWALE AND FIELD UNTIL SOD IS IN PLACE -FINAL GRADE AND SOD -SPLASH BLOCKS AND SUMP EXTENSION -MAX BREAKER AT AC TO BE 40 AMPS -ALL ROUGH INSPECTION NOT PASSED-ADDRESS ALL ITEMS
Occupancy Inspection - Codes Residential Temporary C of O 8/6/2021 8/6/2021 08/06/2021
Miscellaneous Correction
Corrective Action Required
08/06/2021
**TCO UNTIL 9-3-21 -MAINTAIN EROSION CONTROL AND PROTECT SWALE AND FIELD UNTIL SOD IS IN PLACE -FINAL GRADE AND SOD -SPLASH BLOCKS AND SUMP EXTENSION -PROVIDE ENGINEERED REPORT ON FOUNDATION WALL- FROM ALL ROUGH
All Rough Inspection - Residential Passed 8/6/2021 08/06/2021
Misc
Resolved
08/06/2021
-Fireblock through floor Penetration, kitchen -Provide safety glazed window, master bedroom -Provide engineer report regarding cracked foundation wall, west side Ok to insulate
Erosion Control Inspection Residential Passed 9/12/2022 09/12/2022
Misc
Resolved
09/12/2022
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -Restore silt fence at front of lot and remove debris from site and street
Plot Plan Inspection Passed 9/12/2022 09/12/2022
Misc
Corrective Action Required
07/27/2021
7-27-2021 -Site not ready for plot plan inspection -Complete final grade, remove debris and resubmit elevations when complete
Occupancy Inspection - Codes Residential Not Ready 9/12/2022 9/12/2022 09/12/2022
Miscellaneous Correction
Corrective Action Required
08/06/2021
TCO HAS EXPIRED SUBMIT TCO EXTENSION REQUEST FORM. **TCO UNTIL 9-3-21 -pay fees -PROVIDE ENGINEERED REPORT ON FOUNDATION WALL- FROM ALL ROUGH
Occupancy Inspection - Codes Residential Ready for Temp CO 9/30/2022 9/29/2022 09/29/2022
Miscellaneous Correction
Corrective Action Required
09/12/2022
TCO HAS EXPIRED SUBMIT TCO EXTENSION REQUEST FORM. **TCO UNTIL 9-3-21 -pay fees -PROVIDE ENGINEERED REPORT ON FOUNDATION WALL- FROM ALL ROUGH
Occupancy Inspection - Codes Residential Full C of O 9/30/2022 09/30/2022
Miscellaneous Correction
Resolved
09/30/2022
TCO HAS EXPIRED SUBMIT TCO EXTENSION REQUEST FORM. **TCO UNTIL 9-3-21 -pay fees -PROVIDE ENGINEERED REPORT ON FOUNDATION WALL- FROM ALL ROUGH
Documents & Images
Date Uploaded File Type Document Name
09/11/2020 Application Form Permit Application and license tax form
09/14/2020 Letter Codes Residential Plan Review
09/14/2020 Approved Plans Approved Drawings
09/16/2020 Plot Plan Approved Plot Plan
09/16/2020 Receipt Receipt for transaction:2020-006262
09/16/2020 Letter DS Building Permit
10/08/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
11/24/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
01/11/2021 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
03/10/2021 Letter INSPECTION SUMMARY
03/19/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
04/09/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/26/2021 Letter INSPECTION SUMMARY
04/30/2021 Letter INSPECTION SUMMARY
06/22/2021 Letter INSPECTION SUMMARY
07/21/2021 Receipt Receipt for transaction:2021-005821
07/26/2021 Plot Plan Approved As Graded Plot Plan
07/27/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/30/2021 AS- GRADED CITY APPROVED PLOT PLAN
08/04/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter Codes Temporary Certificate of Occupancy
08/06/2021 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter Codes 10 Day Letter
09/12/2022 Engineer Report/Study 2337 SW Old Port Road - Structural Letter (August 12, 2021)
09/28/2022 Receipt Receipt for transaction:2022-007874
09/29/2022 Activity Document 2337 SW Old Port Rd - TCO Extension Form
09/30/2022 Receipt Receipt for transaction:2022-007928
09/30/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home