Permit Application Status

PRRES20202240


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202240
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - FINISHED BASEMENT
08/11/2020
08/18/2020
07/27/2021
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
CURTIS@SABHOMES.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/13/2020 08/18/2020
Dylan Eppert
Basement egress
Corrective Action Required
08/14/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. MISSING LAG FOR EGRESS WELL.
Residential Plan Review Approved 08/13/2020 08/14/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,093.73 $1,093.73 Paid 08/18/2020
8331507-Sewer Connection Fee $480.00 $480.00 Paid 08/18/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/18/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/18/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/18/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/18/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/3/2020 at 9:12 AM 09/03/2020
Misc
Informational
09/03/2020
- 3RD PARTY FOOTING SIGNED & SEALED BY DAVID AINSWORTH - - COMMENTS: UFER LOCATED WEST SIDEWALL ABOUT 3' SOUTH OF NW CORNER -
Erosion Control Inspection Residential Failed 09/16/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/16/2020
-DEFICIENT EROSION CONTROL INSTALLATION, SHALL BE IN COMPLIANCE WITHIN 2 DAYS. -STREET CLEAN UP REQUIRED IMMEDIATELY -REMOVE TRASH FROM SITE
Underslab Plumbing Inspection - Residential Passed 9/29/2020 9/29/2020 09/29/2020
Misc
Informational
09/29/2020
Immediate street cleanup required
Sewer Service Inspection - R Passed 9/30/2020 (11:15) 9/30/2020 09/30/2020
Water Service Inspection - R Partial 10/1/2020 10/1/2020 10/01/2020
Misc
Informational
10/01/2020
Partial approval- approximately 30’ of nonmetallic piping from foundation towards meter location
Water Service Inspection - R Passed 10/1/2020 (1:00) 10/1/2020 10/01/2020
Misc
Informational
10/01/2020
Partial approval- approximately 30’ of nonmetallic piping from foundation towards meter location
Erosion Control Inspection Residential Passed 10/20/2020
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/20/2020
-DEFICIENT EROSION CONTROL INSTALLATION, SHALL BE IN COMPLIANCE WITHIN 2 DAYS. -STREET CLEAN UP REQUIRED IMMEDIATELY -REMOVE TRASH FROM SITE
Miscellaneous Inspection Passed 12/1/2020 12/1/2020 12/02/2020
Misc
Resolved
12/02/2020
Continue 3” fastening grid & provide interior tension straps
Electrical Service Inspection Passed 1/21/2021 1/21/2021 01/21/2021
Gas Service Inspection - Residential Failed 1/21/2021 1/21/2021 01/21/2021
Gas Piping Inspection - Residential Failed 01/21/2021
Misc
Corrective Action Required
01/21/2021
Pressure test gas piping
All Rough Inspection - Residential Failed 1/21/2021 1/21/2021 01/21/2021
Misc
Corrective Action Required
01/21/2021
-Minimum 12” field 6” edge exterior sheathing fastening -Deck ledger and post/beam connection per code -Address rafter to Ridge connection above entry -Pan return and formal dining, would take air from attic space -Mechanically fasten all spliced equipment grounding conductors -Provide joist hanger above master tub -Nail plate protection, conductor stud penetrations master bedroom, basement at bar -Fireblock through floor penetrations -Address over notched studs, garage/dwelling separation wall -Anchor bolt required within 12 inches of plate splices. garage two locations, basement under stairs -Provide conditioned air to basement bedroom -complete fireblocking in basement -Double stud under double floor joist basement exterior bearing wall -Interior wall bracing per plan -Pressure test gas piping
All Rough Inspection - Residential Passed 1/28/2021 1/28/2021 01/28/2021
Misc
Resolved
01/28/2021
-Minimum 12” field 6” edge exterior sheathing fastening -Deck ledger and post/beam connection per code -Address rafter to Ridge connection above entry -Pan return and formal dining, would take air from attic space -Mechanically fasten all spliced equipment grounding conductors -Provide joist hanger above master tub -Nail plate protection, conductor stud penetrations master bedroom, basement at bar -Fireblock through floor penetrations -Address over notched studs, garage/dwelling separation wall -Anchor bolt required within 12 inches of plate splices. garage two locations, basement under stairs -Provide conditioned air to basement bedroom -complete fireblocking in basement -Double stud under double floor joist basement exterior bearing wall -Interior wall bracing per plan -Pressure test gas piping
Gas Service Inspection - Residential Passed 1/28/2021 1/28/2021 01/28/2021
Gas Piping Inspection - Residential Passed 01/28/2021
Misc
Resolved
01/28/2021
Pressure test gas piping
Miscellaneous Inspection Passed 02/11/2021
Misc
Resolved
02/11/2021
Continue 3” fastening grid & provide interior tension straps
Misc
Informational
02/11/2021
Interior braced wall method GB screw pattern approved
Driveway Inspection Partial 3/23/2021 03/23/2021
Misc
Informational
03/23/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 3/23/2021 03/23/2021
Misc
Informational
03/23/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 3/30/2021 3/30/2021 03/30/2021
Misc
Informational
03/23/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 3/30/2021 3/30/2021 03/30/2021
Misc
Informational
03/23/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 4/30/2021 4/30/2021 04/30/2021
Misc
Corrective Action Required
04/30/2021
-Maintenance of erosion control is required until sod is in place -As graded plot plan required -Final grade and sod -Complete gutter/downspout installation -Downspouts and sump piping to discharge minimum 36 inches from foundation -Unable to locate water meter, ensure lid is accessible at grade and meter is 14 to 18 inches below lid -Seal all exterior penetrations, By electric meter enclosure -Complete deck stair landing -Deck post to beam connections per code -Ledger connection to structure per code -Secure raceway at equipment disconnect termination, condensing unit whip -Label dedicated circuit in garage as non-GFCI protected -Provide breaker lockout device for a water heater circuit
Occupancy Inspection - Codes Residential Temporary C of O 04/30/2021
Misc
Corrective Action Required
04/30/2021
-Maintenance of erosion control is required until sod is in place -As graded plot plan required -Final grade and sod -Complete gutter/downspout installation -Downspouts and sump piping to discharge minimum 36 inches from foundation -Unable to locate water meter, ensure lid is accessible at grade and meter is 14 to 18 inches below lid -Seal all exterior penetrations, By electric meter enclosure -Complete deck stair landing -Deck post to beam connections per code -Ledger connection to structure per code -Secure raceway at equipment disconnect termination, condensing unit whip TCO CALID THROUGH 5/30/21
Plot Plan Inspection Failed 5/6/2021 05/06/2021
Misc
Corrective Action Required
05/06/2021
Grading incomplete between house and swale
Occupancy Inspection - Codes Residential Temporary C of O 7/23/2021 7/23/2021 07/23/2021
Misc
Corrective Action Required
04/30/2021
TCO until 7-30-21 -Ledger connection to structure per code -Secure raceway at equipment disconnect termination, condensing unit whip
Plot Plan Inspection Passed 07/23/2021
Misc
Resolved
07/23/2021
Grading incomplete between house and swale
Occupancy Inspection - Codes Residential Full C of O 7/27/2021 7/27/2021 07/27/2021
Misc
Resolved
07/27/2021
TCO until 7-30-21 -Ledger connection to structure per code -Secure raceway at equipment disconnect termination, condensing unit whip
Documents & Images
Date Uploaded File Type Document Name
08/11/2020 E716 - Excise Tax Application
08/11/2020 E716 REVISED PERMIT APPLICATION
08/11/2020 E716 - Air Combustion Calculation
08/11/2020 E716 - Final Plot Plan 8_11_2020
08/11/2020 E716 - Engineered Plans 8_11_2020
08/14/2020 Plans APPROVED HOUSE PLANS
08/14/2020 Letter Codes Residential Plan Review
08/18/2020 Plot Plan APPROVED PLOT PLAN
08/18/2020 Receipt Receipt for transaction:2020-005364
08/18/2020 Letter DS Building Permit
09/03/2020 2353 SW River Trail LSMO Eagle Creek Lot 716 SAB Permit 2020-2240 3rd Party Footing Inspection Report 9-3-20
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
09/30/2020 Letter INSPECTION SUMMARY
10/01/2020 Letter INSPECTION SUMMARY
10/01/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter INSPECTION SUMMARY
12/02/2020 Letter INSPECTION SUMMARY
12/02/2020 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
03/23/2021 Letter INSPECTION SUMMARY
03/23/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
04/30/2021 Letter INSPECTION SUMMARY
04/30/2021 Letter Codes Temporary Certificate of Occupancy
05/04/2021 Plot Plan Approved As Graded Plot Plan
05/06/2021 Letter INSPECTION SUMMARY
05/06/2021 Letter INSPECTION SUMMARY
06/09/2021 E716 Irrigation Application
07/23/2021 Letter Codes Temporary Certificate of Occupancy
07/23/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter Codes Final Certificate of Occupancy
07/27/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home