Summary
PRRES20202156
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - UNCOVERED DECK
08/03/2020
08/04/2020
04/07/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/05/2020 08/04/2020
Kim Brennan
Deck location
Corrective Action Required
08/03/2020

Deck location, with dimensions to property lines must be provided on the plot plan. Please show that this is an uncovered deck
Basement opening elevations
Corrective Action Required
08/04/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Residential Plan Review Approved 08/05/2020 08/03/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,083.95 $1,083.95 Paid 08/04/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/04/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/04/2020
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 08/04/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 08/04/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/04/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/04/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/17/2020 (11:30) 8/17/2020 08/17/2020
Underslab Plumbing Inspection - Residential Passed 9/21/2020 9/21/2020 09/21/2020
Sewer Service Inspection - R Passed 12/7/2020 (11:15) 12/7/2020 12/07/2020
Water Service Inspection - R Partial 12/7/2020 12/7/2020 12/07/2020
Misc
Informational
12/07/2020
-INSPECTED PARTIAL ON PEX FROM MID POINT IN YARD TO HOUSE, OK TO COVER PORTION INSPECTED
Water Service Inspection - R Passed 12/8/2020 (10:30) 12/8/2020 12/08/2020
Misc
Resolved
12/08/2020
-INSPECTED PARTIAL ON PEX FROM MID POINT IN YARD TO HOUSE, OK TO COVER PORTION INSPECTED
All Rough Inspection - Residential Failed 12/23/2020 12/23/2020 12/23/2020
Misc
Corrective Action Required
12/23/2020
-Braced wall method PFH, fasten top plate to header with two rows of 16 the sink her nails at 3 inch on center, see section view 12-S2.0 -No deck inspection at rough in -Ensure all anchor bolts are properly tightened -Fireblock top & bottom plate penetrations in garage -Fireblock stemwall corner furr out in garage -Interior brace wall method LIB strap fastening has been compromised at top plate connection, garage/dwelling separation wall at return air plenum -Fireblock through floor penetration, main level Mechanical chase -Seal penetrations in joist cavities to be used as return air Plenum -Penetrations in floor joists require minimum 2 inch separation between penetrations, replace/repair or provide engineered solution. Several locations first & second floor assemblies -Overbored floor joist, repair/replace or provide engineered solution. Kitchen/living room area -Overbored and cut top plates at loadbearing interior wall require minimum 16 gauge 1.5” width structural strap spanning minimum 6” each side of penetration or cut with four nails on each side of penetration or cut. Garage/dwelling separation wall -Complete furr out of plumbing in living room -12 inch OC fastening stud to stud and abutting studs at all brace wall corners -Mid span support for all vertical DWV 2 inch or smaller -seal penetration within stud cavity used as return plenum, Main level bath facia board -Provide adequate support of stair landings -Provide joist hangers at headered floor joist, basement -Two 2 x 10 at load bearing wall, basement, between stair stringers, see plan -Rim board Headers to span minimum 6 inches beyond outer most full height stud, Double windows basement -Snow block bedroom four exterior wall at connection to fireplace roof -Fireblock vertical to horizontal, master bath raised ceiling top plates, Exterior wall and clothes dryer exhaust duct -Provide stud shoes, master bath lav plumbing exterior wall and properly fasten studs shoes that are currently in place
Electrical Service Inspection Passed 12/23/2020 12/23/2020 12/23/2020
Gas Piping Inspection - Residential Passed 12/23/2020 12/23/2020 12/23/2020
Gas Service Inspection - Residential Passed 12/23/2020 12/23/2020 12/23/2020
All Rough Inspection - Residential Failed 1/7/2021 1/7/2021 01/07/2021
Misc
Corrective Action Required
12/23/2020
-Seal penetrations in joist cavities to be used as return air Plenum -1st floor kitchen ceiling -Penetrations in floor joists require minimum 2 inch separation between penetrations, replace/repair or provide engineered solution. Several locations first & second floor assemblies -Overbored floor joist, repair/replace or provide engineered solution. Kitchen/living room area -Fireblock plumbing furr out in living room -area too large for loose insulation -Provide joist hangers at headered floor joist, basement -Fireblock vertical to horizontal, master bath raised ceiling top plates, Exterior wall and clothes dryer exhaust duct
All Rough Inspection - Residential Passed 1/11/2021 1/11/2021 01/11/2021
Misc
Resolved
01/11/2021
Driveway Inspection Partial 1/29/2021 (P.M.) 1/29/2021 01/29/2021
Misc
Informational
01/29/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 2/5/2021 2/5/2021 02/22/2021
Misc
Informational
01/29/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 3/8/2021 3/8/2021 03/08/2021
Misc
Corrective Action Required
03/08/2021
-Final grade -Sod -Complete stone/siding front of house at garage -Terminate exterior light fixtures at garage -Guardrail required at front porch, more than 30” from grade -Splash blocks at all downspout and sump pump discharge locations, minimum36” distance from foundation -seal all penetrations in siding, seal along top of AC disconnect and meter can -(2) bolts at each post/beam connection per code -bolt outer ply of rim to ledger at attach inner ply with angel clip at deck -Cover plates required on all switches and receptacles -security screws at backdoor - (2) 3" screws on all hinges and strike plate -Minimum (1) shower/bath must be operational
Occupancy Inspection - Codes Residential Temporary C of O 3/10/2021 3/10/2021 03/10/2021
Misc
Corrective Action Required
03/08/2021
-Final grade -Sod -Guardrail required at front porch, more than 30” from grade -Splash blocks at all downspout and sump pump discharge locations, minimum36” distance from foundation -(2) bolts at each post/beam connection per code -bolt outer ply of rim to ledger at attach inner ply with angel clip at deck OK FOR TCO - TCO EXPIRES 3/24/21
Plot Plan Inspection Passed 04/07/2021
Occupancy Inspection - Codes Residential Full C of O 4/7/2021 4/7/2021 04/07/2021
Misc
Resolved
04/07/2021
Documents & Images
Date Uploaded File Type Document Name
08/03/2020 Letter Scope of Work and license tax form
08/03/2020 Drawing Approved Drawings
08/03/2020 Drawing Approved Truss Layout
08/03/2020 Drawing Approved Truss Package
08/04/2020 Letter Codes Residential Plan Review
08/04/2020 Plot Plan Approved Plot Plan
08/04/2020 Receipt Receipt for transaction:2020-004939
08/04/2020 Letter DS Building Permit
08/17/2020 Letter INSPECTION SUMMARY
08/17/2020 image.jpg
08/17/2020 image.jpg0
08/18/2020 Engineer Report/Study Lot 105 Manor at Stoney Creek soil inspection
09/21/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/09/2021 MN105 Overbored Floor Joist Letter
01/11/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
02/22/2021 Letter INSPECTION SUMMARY
03/08/2021 Letter INSPECTION SUMMARY
03/10/2021 Letter Codes Temporary Certificate of Occupancy
04/07/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter Field Certificate of Occupancy
04/07/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home