Summary
PRRES20202107
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 02/24/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 04/02/2021 12:00 AM by username 'Patrick Schonfeldt'.
07/29/2020
07/29/2020
05/20/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/31/2020 07/29/2020
Kim Brennan
Residential Plan Review Approved 07/31/2020 07/29/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,227.59 $1,227.59 Paid 07/29/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/29/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 07/29/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 07/29/2020
8331504-EFHB Middle Big Creek, Full $636.12 $636.12 Paid 07/29/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 07/29/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/29/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $250.00 $250.00 Paid 05/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/12/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Miscellaneous Inspection Failed 8/26/2020 8/26/2020 08/26/2020
Misc
Corrective Action Required
08/26/2020
- HOUSE NOT READY FOR ALL ROUGH INSPECTION SCHEDULED 8/26 -
Footing Inspection - Residential Passed 9/14/2020 (1:00) 9/14/2020 09/14/2020
Underslab Plumbing Inspection - Residential Passed 10/6/2020 10/6/2020 10/06/2020
Piers/Caissons Inspection - Residential Passed 11/16/2020 (11:00) 11/16/2020 11/16/2020
All Rough Inspection - Residential Not Ready 1/4/2021 1/4/2021 01/04/2021
Misc
Corrective Action Required
01/04/2021
NO INSPECTION PERFORMED -NO CITY APPROVED HOUSE PLANS OR TRUSS PLANS ON SITE -
Electrical Service Inspection Passed 1/7/2021 1/7/2021 01/07/2021
Gas Piping Inspection - Residential Passed 1/7/2021 1/7/2021 01/07/2021
Gas Service Inspection - Residential Failed 1/7/2021 1/7/2021 01/07/2021
Misc
Corrective Action Required
01/07/2021
-GAS PRESSURE AT 8 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 1/7/2021 01/07/2021
Misc
Corrective Action Required
01/04/2021
-Anchor bolts required within 12” of plate breaks in garage -Fireblock plumbing furred down at garage wall -Secure all DWV 2” or less at mid point -Security blocking at exterior doors -Seal all penetrations through air returns and plenums -Penetrations bored in floor joists less than 2” from end of member and less than 2” from additional bores in joist - 1st floor above refrigerator and along kitchen area -Floor joists penetration for pex less than 2” apart, 1st floor living room near windows -Fireblock deadspace at foyer/living room -Joist hangers at joist to lvl connection 1st floor front entry -12”oc nailing at all abutting and intersecting wall corners, braced wall panels -Seal all top and bottom plate penetrations -Insulate first, then solid block at cantilevers per plans -(2) 2x6 at front door/foyer closet corner per plans -Truss hangers per plans -Attic access garage per plans -LIB bracing per plans -connect 2x6 top plate to 2x4 top plate at 2nd floor stairs -Bocca protection plate at DWV bottom plate 2nd floor master bed wall -Fireblock 2nd floor HVAC chase hall -structural straps at all top plates bored 50% or more all exterior walls and all interior load bearing walls -Stud shoes at all DWV master bath exterior wall, nail all stud shoes currently installed -Penetrations for NM in floor joists less than 2” from end of joist -Several locations throughout basement -DWV cleanout covered at bottom basement stair -Install lag bolts at deck ledger per code -(2) bolts at post rim connections at deck -Install angel clip on inner ply at rim at deck ledger -Nail all joist hangers at deck
Gas Service Inspection - Residential Failed 1/12/2021 1/12/2021 01/12/2021
Misc
Corrective Action Required
01/07/2021
-GAS PRESSURE AT 8 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 1/12/2021 1/12/2021 01/12/2021
Misc
Corrective Action Required
01/07/2021
-Secure all DWV 2” or less at mid point -Seal all penetrations through air returns and plenums -kitchen ceiling joist penetrations -Penetrations bored in floor joists less than 2” from end of member and less than 2” from additional bores in joist - 1st floor above refrigerator and along kitchen area - replace or submit engineered solution -Floor joists penetration for pex less than 2” apart, 1st floor living room near windows - replace or submit engineered solution -Seal all top and bottom plate penetrations - above front door 2nd floor top plate -Insulate first, then solid block at cantilevers per plans -Truss hangers per plans -Attic access garage per plans -LIB bracing per plans -Fireblock 2nd floor HVAC chase hall -structural straps at all top plates bored 50% or more all exterior walls and all interior load bearing walls -Stud shoes at all DWV master bath exterior wall, nail all stud shoes currently installed -Penetrations for NM in floor joists less than 2” from end of joist -Several locations throughout basement - replace or submit engineered solution -DWV cleanout covered at bottom basement stair
Sewer Service Inspection - R Passed 1/14/2021 1/14/2021 01/14/2021
Water Service Inspection - R Partial 1/14/2021 1/14/2021 01/14/2021
Misc
Informational
01/14/2021
-INSPECTED PARTIAL PEX WATER AT MID POINT OF YARD TO HOUSE ENTRANCE
Gas Service Inspection - Residential Passed 1/14/2021 1/14/2021 01/14/2021
Misc
Resolved
01/14/2021
All Rough Inspection - Residential Failed 1/14/2021 1/14/2021 01/14/2021
Misc
Corrective Action Required
01/12/2021
-Seal all penetrations through air returns and plenums -kitchen ceiling joist penetrations -Penetrations bored in floor joists less than 2” from end of member and less than 2” from additional bores in joist - 1st floor above refrigerator and along kitchen area - replace or submit engineered solution -Floor joists penetration for pex less than 2” apart, 1st floor living room near windows - replace or submit engineered solution -Seal all top and bottom plate penetrations - above front door 2nd floor top plate -Insulate first, then solid block at cantilevers per plans -Truss hangers per plans -covered deck -Attic access garage per plans -Fireblock 2nd floor HVAC chase hall -seal gaps at penetration(s) -structural straps at all top plates bored 50% or more all exterior walls and all interior load bearing walls - see master bath top exterior wall -Stud shoe at DWV master bath exterior wall, over 40% bore of stud -Penetrations for NM in floor joists less than 2” from end of joist -Several locations throughout basement - replace or submit engineered solution -DWV cleanout covered at bottom basement stair
Water Service Inspection - R Passed 1/19/2021 (10:45) 1/19/2021 01/19/2021
Misc
Resolved
01/19/2021
All Rough Inspection - Residential Failed 1/19/2021 1/19/2021 01/19/2021
Misc
Corrective Action Required
01/14/2021
-Seal all penetrations through air returns and plenums -kitchen ceiling joist penetrations -Penetrations bored in floor joists less than 2” from end of member and less than 2” from additional bores in joist - 1st floor above refrigerator and along kitchen area - replace or submit engineered solution -Floor joists penetration for pex less than 2” apart, 1st floor living room near windows - replace or submit engineered solution -Truss hangers per plans -covered deck -Attic access garage per plans -Penetrations for NM in floor joists less than 2” from end of joist -Several locations throughout basement - replace or submit engineered solution -DWV cleanout covered at bottom basement stair
All Rough Inspection - Residential Failed 1/25/2021 1/25/2021 01/25/2021
Misc
Corrective Action Required
01/19/2021
-Penetrations bored in floor joists less than 2” from end of member and less than 2” from additional bores in joist - 1st floor above refrigerator and along kitchen area - replace or submit engineered solution -Floor joists penetration for pex less than 2” apart, 1st floor living room near windows - replace or submit engineered solution -Penetrations for NM in floor joists less than 2” from end of joist -Several locations throughout basement - replace or submit engineered solution NO ENGINEER LETTER ON FILE IN PERMIT - SUBMIT LETTER TO DEVTECH@CITYOFLS.NET -DWV cleanout covered at bottom basement stair **OK TO INSULATE**
Driveway Inspection Partial 2/3/2021 (P.M.) 2/3/2021 02/03/2021
Misc
Informational
02/03/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Failed 2/8/2021 2/8/2021 02/08/2021
Misc
Corrective Action Required
01/25/2021
-Floor joists penetration for pex less than 2” apart, 1st floor living room near windows - replace or submit engineered solution -Penetrations for NM in floor joists less than 2” from end of joist -Several locations throughout basement - replace or submit engineered solution NO ENGINEER LETTER ON FILE IN PERMIT - SUBMIT LETTER TO DEVTECH@CITYOFLS.NET -DWV cleanout covered at bottom basement stair **OK TO INSULATE**
All Rough Inspection - Residential Failed 2/10/2021 2/10/2021 02/10/2021
Misc
Corrective Action Required
02/08/2021
-Floor joists penetration for pex less than 2” apart, 1st floor living room near windows - replace or submit engineered solution -Penetrations for NM in floor joists less than 2” from end of joist -Several locations throughout basement - replace or submit engineered solution NO ENGINEER LETTER ON FILE IN PERMIT - SUBMIT LETTER TO DEVTECH@CITYOFLS.NET -DWV cleanout covered at bottom basement stair **OK TO INSULATE** ENG letter does not address multiple locations. Strap added in the kitchen does not meet the ENG letter. Please address all location , some joist were added in the basement.
All Rough Inspection - Residential Not Ready 2/11/2021 2/11/2021 02/11/2021
Misc
Corrective Action Required
02/10/2021
-Floor joists penetration for pex less than 2” apart, 1st floor living room near windows - replace or submit engineered solution -Penetrations for NM in floor joists less than 2” from end of joist -Several locations throughout basement - replace or submit engineered solution -DWV cleanout covered at bottom basement stair - plumbing contractor on site working on issue at time of inspection **OK TO INSULATE** ENG letter does not address multiple locations. Please address all location , some joist were added in the basement.
Driveway Inspection Passed 2/10/2021 2/10/2021 02/22/2021
Misc
Informational
02/03/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Failed - Stop Work 2/24/2021 02/24/2021
Misc
Corrective Action Required
02/11/2021
-Floor joists penetration for pex less than 2” apart, 1st floor living room near windows - replace or submit engineered solution -Penetrations for NM in floor joists less than 2” from end of joist -Several locations throughout basement - replace or submit engineered solution -DWV cleanout covered at bottom basement stair - plumbing contractor on site working on issue at time of inspection **OK TO INSULATE** ENG letter does not address multiple locations. Please address all location , some joist were added in the basement. -2/24/21 - HOUSE HAS BEEN ROCKED WITHOUT APPROVAL, REMOVE ALL SHEETROCK FROM HOUSE - STOP WORK ORDER ISSUES
All Rough Inspection - Residential Passed 4/2/2021 4/2/2021 04/02/2021
Misc
Resolved
04/02/2021
Erosion Control Inspection Residential Passed 05/17/2021
Plot Plan Inspection Passed 05/17/2021
Occupancy Inspection - Codes Residential Failed 5/17/2021 5/17/2021 05/17/2021
Misc
Corrective Action Required
05/17/2021
-Install spindles at basement stairs -Anti siphon device required at spigot on main water line in basement, ensure set screw head is clipped off anti siphon after installation -(2) 1/2" through bolts required at each post/beam connection per code at deck, R507.5.1(2)
Occupancy Inspection - Codes Residential Failed 5/19/2021 5/19/2021 05/19/2021
Misc
Corrective Action Required
05/17/2021
-Anti siphon device required at spigot on main water line in basement, ensure set screw head is clipped off anti siphon after installation
Occupancy Inspection - Codes Residential Full C of O 5/20/2021 5/20/2021 05/20/2021
Misc
Resolved
05/20/2021
Documents & Images
Date Uploaded File Type Document Name
07/29/2020 Letter Permit Application and license tax form
07/29/2020 Drawing Approved Drawings
07/29/2020 Drawing Approved Truss Layout
07/29/2020 Drawing Approved Truss Package
07/29/2020 Plot Plan Approved Plot Plan
07/29/2020 Receipt Receipt for transaction:2020-004817
07/29/2020 Letter DS Building Permit
08/26/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
10/06/2020 Letter INSPECTION SUMMARY
11/16/2020 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/12/2021 Letter INSPECTION SUMMARY
01/12/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
02/04/2021 94 Manor at Stoney Creek Holes in Floor Joists Letter
02/08/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
02/22/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter Stop Work Order
02/24/2021 B607D296-6053-4700-9495-C16942141D78.jpeg
02/24/2021 82EFFFF4-BAD8-4123-AF64-D4868C512D37.jpeg
03/18/2021 02E43B0A-9701-469F-9FD1-275AB01E890F
03/31/2021 Lot 94 Structural Inspection - Signed
04/02/2021 Letter INSPECTION SUMMARY
05/12/2021 Receipt Receipt for transaction:2021-002910
05/17/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
05/19/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter Field Certificate of Occupancy
05/20/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.