Summary
PRRES20201850
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
07/08/2020
07/10/2020
05/14/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/10/2020 07/10/2020
Kim Brennan
City infrustructure
Corrective Action Required
07/09/2020

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. Please show fire hydrant located at the front of the lot
As-graded plot plan
Corrective Action Required
07/09/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 07/10/2020 07/08/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $969.91 $969.91 Paid 07/10/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/10/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/10/2020
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 07/10/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 07/10/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 07/10/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 07/10/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 08/05/2020
Underslab Plumbing Inspection - Residential Passed 9/8/2020 9/8/2020 09/08/2020
Electrical Service Inspection Failed 11/23/2020 11/23/2020 11/23/2020
Misc
Corrective Action Required
11/23/2020
- COLOR CODE/LABEL GROUNDING ELECTRODE CONDUCTOR AT DISCONNECT
Gas Piping Inspection - Residential Failed 11/23/2020 11/23/2020 11/23/2020
Misc
Corrective Action Required
11/23/2020
-Install gas line at fireplace -Install gas line, no gas lines currently installed in house -Pressure test required
Gas Service Inspection - Residential Failed 11/23/2020 11/23/2020 11/23/2020
Misc
Corrective Action Required
11/23/2020
-Install gas line at fireplace -Install gas line, no gas lines currently installed in house -Pressure test required
All Rough Inspection - Residential Failed 11/23/2020 11/23/2020 11/23/2020
Misc
Corrective Action Required
11/23/2020
-Floor joist over notched for DWV above garage -Joist hangers at floor joist to dbl joist header connection in garage at dbl door, over 4’ -Floor joist bored for DWV within 2” from end of joist, above dbl car door in garage -(2) 2x4 at wall, NW corner garage per plans -Header for cut floor joist at box out for HVAC in pantry, joist currently supported by non load bearing wall -Bores for NM and DWV in floor joist less than 2” apart, above 1st floor bath -Secure all DWV 2” or less at mid point -Seal all top and bottom plate penetrations -Floor joist over notched for DWV above living room -protection plates at pex - kitchen/living side 1st floor water closet -Joist hanger at stair header to dbl joist hanger connection at 1st floor, over 4’ -LIB bracing per plans -Remove lids/trim at front porch and back deck to allow for inspection of all trusses/hangers/hold down straps -Nail hold down device at front porch -Structural straps at top plate bored for DWV exterior bearing wall, bed #3 2nd floor -BOCCA protection plate at DWV bottom plate, 2nd floor hall closet, bed #3 2nd floor -Joist hangers required at sgl joists to dbl joist connection at cantilever, 4’ -Color code/label grounding electrode conductor -UFER ground located in HVAC duct must be made accessible and location labeled -b vent at furnace requires 1” clearance from combustibles -Over notched floor joist for DWV, NW side basement -Tighten all anchor bolts - basement -Install gas line at fireplace -Install gas line, no gas lines currently installed in house -Pressure test required -Lag ledger to house at deck per code -Bolt outer ply of rim to ledger at deck and add angel clip to inner ply -Provide (2) bolts per post/rim connection at deck -Exterior sheathing to be fastened 6” oc edges & 12” field
Sewer Service Inspection - R Passed 12/1/2020 12/01/2020
Water Service Inspection - R Passed 12/2/2020 12/02/2020
Gas Service Inspection - Residential Failed 12/8/2020 12/8/2020 12/08/2020
Misc
Corrective Action Required
11/23/2020
-SECURE GAS FLEX LINE AT FIREPLACE -GAS PRESSURE AT 5 PSI, MUST MAINTAIN 10 PSI FOR 15 MINUTES
Electrical Service Inspection Passed 12/8/2020 12/8/2020 12/08/2020
Misc
Resolved
12/08/2020
Gas Piping Inspection - Residential Failed 12/8/2020 12/8/2020 12/08/2020
Misc
Corrective Action Required
11/23/2020
-SECURE GAS FLEX LINE AT FIREPLACE
All Rough Inspection - Residential Failed 12/8/2020 12/8/2020 12/08/2020
Misc
Corrective Action Required
12/08/2020
-Re establish silt fence and gravel filter, clean mud and gravel from street, address erosion control issues before scheduling reinspection -address cut pex, garage ceiling -Bores for NM and DWV in floor joist less than 2” apart, above 1st floor bath -address cut DWV above living room -protection plates at pex top plate - kitchen/living side 1st floor water closet -b vent at furnace requires 1” clearance from combustibles -Over notched floor joist for DWV, NW side basement OK TO INSULATE
Erosion Control Inspection Residential Failed 12/8/2020 12/8/2020 12/08/2020
Misc
Corrective Action Required
12/08/2020
- Re establish silt fence and gravel filter, clean mud and gravel from street, address before scheduling reinspection
Gas Service Inspection - Residential Passed 12/15/2020 12/15/2020 12/15/2020
Misc
Resolved
12/15/2020
Gas Piping Inspection - Residential Passed 12/15/2020 12/15/2020 12/15/2020
Misc
Resolved
12/15/2020
All Rough Inspection - Residential Passed 12/15/2020 12/15/2020 12/15/2020
Misc
Resolved
12/15/2020
Sidewalk Inspection Partial 1/12/2021 (P.M.) 1/12/2021 01/12/2021
Misc
Informational
01/12/2021
1-12-21 1:01PM The forms are set and are ADA compliant at this time. The aggregate is compacted.
Driveway Inspection Partial 1/12/2021 1/12/2021 01/12/2021
Misc
Informational
01/12/2021
1-12-21 1:05pm The forms are set and the aggregate is compacted.
Sidewalk Inspection Passed 1/21/2021 (P.M.) 1/21/2021 01/21/2021
Misc
Informational
01/12/2021
1-12-21 1:01PM The forms are set and are ADA compliant at this time. The aggregate is compacted.
Driveway Inspection Passed 1/21/2021 (P.M.) 1/21/2021 01/21/2021
Misc
Informational
01/12/2021
1-12-21 1:05pm The forms are set and the aggregate is compacted.
Occupancy Inspection - Codes Residential Failed 2/19/2021 2/19/2021 02/19/2021
Misc
Corrective Action Required
02/19/2021
-Maintain erosion control on lot until sod is placed -As graded plot plan required prior to sodding, submit for review -Final grade and sod -Complete stone/siding at garage and front porch -Guardrail required at front porch, more than 30” from grade -terminate exterior receptacle at front porch -Gutters and downpours required -Splash blocks at all down spout and sump pump discharge locations, minimum 36” from foundation **EXTERIOR ITEMS LIST MAY BE INCOMPLETE DUE TO WEATHER CONDITIONS AT TIME OF INSPECTION**
Occupancy Inspection - Codes Residential Failed 2/23/2021 2/23/2021 02/23/2021
Misc
Corrective Action Required
02/19/2021
-Maintain erosion control on lot until sod is placed -As graded plot plan required prior to sodding, submit for review -Final grade and sod -Guardrail required at front porch, more than 30” from grade -terminate exterior receptacle at front porch -Gutters and downpours required -Splash blocks at all down spout and sump pump discharge locations, minimum 36” from foundation
Occupancy Inspection - Codes Residential Temporary C of O 2/23/2021 2/23/2021 02/23/2021
Misc
Corrective Action Required
02/23/2021
-Maintain erosion control on lot until sod is placed -As graded plot plan required prior to sodding, submit for review -Final grade and sod -Guardrail required at front porch, more than 30” from grade -Gutters and downpours required -Splash blocks at all down spout and sump pump discharge locations, minimum 36” from foundation OK FOR TCO - TCO EXPIRES 3/17/21
Occupancy Inspection - Codes Residential Temporary C of O 5/4/2021 5/4/2021 05/04/2021
Misc
Corrective Action Required
02/23/2021
-As graded plot plan required prior to sodding, submit for review -Splash blocks at all down spout and sump pump discharge locations, minimum 36” from foundation OK FOR TCO - TCO EXPIRES 5/25/2021
Plot Plan Inspection Passed 5/5/2021 05/05/2021
Erosion Control Inspection Residential Passed 05/14/2021
Misc
Resolved
05/14/2021
Occupancy Inspection - Codes Residential Full C of O 5/14/2021 5/14/2021 05/14/2021
Misc
Resolved
05/14/2021
Documents & Images
Date Uploaded File Type Document Name
07/08/2020 Letter Permit Application and license tax form
07/09/2020 Letter Codes Residential Plan Review
07/09/2020 Drawing Approved Drawings
07/09/2020 Drawing Approved Truss Package
07/09/2020 Drawing Approved Truss Layout
07/10/2020 Plot Plan Approved Plot Plan
07/10/2020 Receipt Receipt for transaction:2020-004284
07/10/2020 Letter DS Building Permit
08/05/2020 52 Manor at Stoney Creek footing
08/05/2020 Letter INSPECTION SUMMARY
08/13/2020 Lot 52 Manor at Stonry Creek wall
09/08/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter INSPECTION SUMMARY
12/02/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
01/12/2021 Letter INSPECTION SUMMARY
01/12/2021 Letter INSPECTION SUMMARY
01/12/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
02/19/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter Codes Temporary Certificate of Occupancy
05/04/2021 Letter Codes Temporary Certificate of Occupancy
05/04/2021 Plot Plan Approved As Graded Plot Plan
05/05/2021 Letter INSPECTION SUMMARY
05/14/2021 Letter INSPECTION SUMMARY
05/14/2021 Letter Field Certificate of Occupancy
05/14/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home