Permit Application Status

PRRES20201848


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201848
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - UNFINISHED BASEMENT - SUSPENDED SLAB
07/07/2020
07/15/2020
02/02/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/09/2020 07/15/2020
Dylan Eppert
Easements
Corrective Action Required
07/10/2020

All easements with dimensions must be provided on the plot plan. MISSING 20.10' U/E IN REAR YARD
Drainage swales
Corrective Action Required
07/10/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide
As-graded plot plan
Corrective Action Required
07/10/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Planning Review (RES) Approved 07/14/2020 07/10/2020
Dylan Eppert
Residential Plan Review Approved 07/09/2020 07/10/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,404.48 $1,404.48 Paid 07/15/2020
Right of Way Permit Fee $80.00 $80.00 Paid 07/15/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/15/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 07/15/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 07/15/2020
Water Meter Fee $455.54 $455.54 Paid 07/15/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/24/2020 8/24/2020 08/24/2020
Underslab Plumbing Inspection - Residential Failed 9/15/2020 9/15/2020 09/15/2020
Misc
Corrective Action Required
09/15/2020
- Connect interior drain tile to sump basin - Interior drain tile to reach opposite end of foundation footing if running diagonally across basement floor - Seat DWV on gravel base N wall
Underslab Plumbing Inspection - Residential Passed 9/16/2020 9/16/2020 09/16/2020
Misc
Resolved
09/16/2020
Suspended Slab Inspection Failed 9/21/2020 09/21/2020
Misc
Corrective Action Required
09/21/2020
NO INSPECTION PERFORMED - NO CITY APPROVED PLANS ON SITE
Suspended Slab Inspection Passed 9/22/2020 (8:00) 9/22/2020 09/21/2020
Misc
Resolved
09/21/2020
Electrical Service Inspection Passed 11/13/2020 11/13/2020 11/13/2020
All Rough Inspection - Residential Failed 11/13/2020 11/13/2020 11/13/2020
Misc
Corrective Action Required
11/13/2020
-Anchor bolts within 12” of plate break in garage -Anchor all columns -Fireblock under cantilever in garage -H2.5 truss straps at all hip trusses -Fireblock furred downs and furred out in garage -Fireblock vertical to horizontal at furred down in garage -Damaged NM shielding at kitchen wall, S side -Address kitchen wall (4) stud pack for triple lvl bearing, bored less than 5/8” on either side of bore, bored more than 40% for DWV, no stud shoes -Structural straps at all top plates bored more than 50% at all exterior walls and interior load bearing walls -fur down for HVAV and DWV above living room windows -Fireblock chases living room -Secure gas flex line at fireplace -Fireblock HVAC chase kitchen -Fireblock above refrigerator walls -Fireblock deadspace between walls at kitchen -Fireblock deadspace at dining room -Fireblock HVAC chase dining room -(4) 2x4 stud pack at dining room soffit per plans -LIB bracing per plans -Connect top plates at top stair landing at 2x6 to 2x4 wall -Attach H2.5 straps to framing and not siding at covered patio -Truss hangers per plans -Snow block 2nd floor -22”x36” attic access per plans 2nd floor -(2) studs at dbl girder truss bearing master closet -Truss bracing per plans -Joist hangers at stair landing header, over 4’ -Complete electrical/lighting at suspended slab space in basement -(3) 2x10 floor joists above basement stair landing per plans -Complete HVAC equipment install and complete gas line install -Add water heater circuit -Address cleanout at bottom of basement stairs -Repair damaged tyvek at front of house with tyvek tape -Exterior sheathing to be fastened 6” oc edges & 12” field
Gas Piping Inspection - Residential Failed 11/13/2020 11/13/2020 11/13/2020
Misc
Corrective Action Required
11/13/2020
-Complete HVAC equipment install and complete gas line install -Secure gas flex line at fireplace
Gas Service Inspection - Residential Failed 11/13/2020 11/13/2020 11/13/2020
Misc
Corrective Action Required
11/13/2020
-Complete HVAC equipment install and complete gas line install -Secure gas flex line at fireplace -Gas pressure test required
All Rough Inspection - Residential Failed 11/17/2020 11/17/2020 11/17/2020
Misc
Corrective Action Required
11/17/2020
-Fireblock furred downs and furred out in garage - insulation must be unfaced when used as Fireblock -Seal NM penetration at top plate, kitchen sink wall -Structural straps at all top plates bored more than 50% at all exterior walls and interior load bearing walls -Fireblock deadspace between walls at kitchen - insulation must be unfaced when used as Fireblock -Complete electrical/lighting at suspended slab space in basement -Complete HVAC equipment install and complete gas line install -Address cleanout at bottom of basement stairs OK TO INSULATE, REMOVE INSULATION FROM ANY INSPECTION ITEMS
All Rough Inspection - Residential Failed 11/18/2020 11/18/2020 11/18/2020
Misc
Corrective Action Required
11/17/2020
-Complete electrical/lighting at suspended slab space in basement -Complete HVAC equipment install and complete gas line install OK TO INSULATE AND ROCK
Gas Piping Inspection - Residential Passed 11/19/2020 11/19/2020 11/19/2020
Misc
Resolved
11/19/2020
Gas Service Inspection - Residential Passed 11/19/2020
Misc
Resolved
11/19/2020
Sewer Service Inspection - R Passed 12/1/2020 12/01/2020
Water Service Inspection - R Passed 12/2/2020 (11:30) 12/2/2020 12/02/2020
Driveway Inspection Passed 12/17/2020 (P.M.) 12/17/2020 12/18/2020
Miscellaneous Correction
Informational
12/18/2020
On Thursday, 12-17-2020. A sidewalk inspection was completed and passed city standards.
All Rough Inspection - Residential Passed 01/15/2021
Misc
Resolved
01/15/2021
=
Occupancy Inspection - Codes Residential Failed 1/15/2021 1/15/2021 01/15/2021
Misc
Corrective Action Required
01/15/2021
-Submit as graded plot plan for review -Complete final grade and sod -Complete stone/siding at front porch and garage -splash blocks at all downspout and sump pump discharge locations, minimum 36” distance from foundation -cover plate at fireplace receptacle -complete drywall under garage door ceiling track attachment brackets -Secure fallen HVAV duct brackets in basement -emergency egress ladder required at basement well -secure AC electrical whip within 12” of disconnect
Plot Plan Inspection Failed 1/22/2021 01/22/2021
Misc
Corrective Action Required
01/22/2021
-CORRECT GRADE AT WEST SIDE OF LOT AND SOUTHWEST CORNER OF GRADE AT HOUSE NEAR GAS METER
Occupancy Inspection - Codes Residential Failed 1/26/2021 1/26/2021 01/26/2021
Misc
Corrective Action Required
01/15/2021
-See plot plan inspection report -Complete stone/siding at front porch and garage -complete drywall under garage door ceiling track attachment brackets -Secure fallen HVAV duct brackets in basement
Occupancy Inspection - Codes Residential Temporary C of O 1/27/2021 1/27/2021 01/27/2021
Misc
Corrective Action Required
01/26/2021
-See plot plan inspection report -Complete stone/siding at front porch and garage OK FOR TCO - TCO EXPIRES 2/10/21
Plot Plan Inspection Passed 2/2/2021 2/2/2021 02/02/2021
Misc
Resolved
02/02/2021
Occupancy Inspection - Codes Residential Full C of O 2/2/2021 2/2/2021 02/02/2021
Misc
Resolved
02/02/2021
Documents & Images
Date Uploaded File Type Document Name
07/07/2020 Application Form HT #24 - PERMIT APPLICATION
07/07/2020 24 HAWTHORNE RIDGE TRUSS LAYOUT
07/07/2020 400370
07/07/2020 LOT 24 FINAL
07/07/2020 HT #24 - Charleston - Mediterranean - Sheets- signed
07/10/2020 Plans APPROVED HOUSE PLANS
07/10/2020 Specifications approved truss package
07/10/2020 Drawing APPROVED TRUSS LAYOUT
07/10/2020 Plans APPROVED HOUSE ELEVATIONS
07/10/2020 Letter Codes Residential Plan Review
07/15/2020 Plot Plan APPROVED PLOT PLAN
07/15/2020 Receipt Receipt for transaction:2020-004476
07/15/2020 Letter DS Building Permit
08/03/2020 24 Hawthorne Ridge Suspended Slab Beam Letter
08/19/2020 24 Hawthorne Ridge Foundation Wall Spec Letter - Signed
08/24/2020 24 Hawthorne Ridge footing
08/24/2020 Lot 24 Hawthorne Ridge Wall Inspection
08/24/2020 Letter INSPECTION SUMMARY
09/15/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/21/2020 Letter INSPECTION SUMMARY
09/21/2020 Letter INSPECTION SUMMARY
11/13/2020 Letter INSPECTION SUMMARY
11/13/2020 Letter INSPECTION SUMMARY
11/13/2020 Letter INSPECTION SUMMARY
11/13/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
11/18/2020 Letter INSPECTION SUMMARY
11/19/2020 Letter INSPECTION SUMMARY
11/19/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter INSPECTION SUMMARY
12/02/2020 Letter INSPECTION SUMMARY
01/15/2021 Letter INSPECTION SUMMARY
01/15/2021 Letter INSPECTION SUMMARY
01/21/2021 Plot Plan APPROVED AS-BUILT
01/22/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter Codes Temporary Certificate of Occupancy
02/02/2021 Letter INSPECTION SUMMARY
02/02/2021 Letter Field Certificate of Occupancy
02/02/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home