Permit Application Status

PRRES20201448


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201448
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS PACKAGE - FINISHED BASEMENT
06/03/2020
06/10/2020
03/09/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/05/2020 06/09/2020
Dylan Eppert
Lot elevations
Corrective Action Required
06/05/2020

Existing and finish elevations at all property corners must be provided on the plot plan. MID POINT ELEVATION ON LOT 85 IS 993.60, WHILE THIS LOT HAS A MIDPOINT ELEVATION OF 995 PLEASE CLARIFY.
Residential Plan Review Approved 06/05/2020 06/05/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,027.31 $1,027.31 Paid 06/10/2020
8331504-EFHB Middle Big Creek, Full $401.76 $401.76 Paid 06/10/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 06/10/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 06/10/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 06/10/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/10/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/10/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 01/13/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 07/24/2020
Misc
Corrective Action Required
07/24/2020
- Footing poured without inspection, submit third party inspection report
Footing Inspection - Residential Passed 7/30/2020 7/30/2020 07/30/2020
Misc
Resolved
07/30/2020
Underslab Plumbing Inspection - Residential Passed 8/4/2020 8/4/2020 08/04/2020
Electrical Service Inspection Passed 10/5/2020 10/5/2020 10/05/2020
Gas Piping Inspection - Residential Passed 10/5/2020 10/5/2020 10/05/2020
Gas Service Inspection - Residential Passed 10/5/2020 10/5/2020 10/05/2020
All Rough Inspection - Residential Failed 10/5/2020 10/5/2020 10/05/2020
Misc
Corrective Action Required
10/05/2020
-Clean mud and gravel and street in front of lot -Seal all top plate penetrations -Structural straps at all exterior walls and interior load bead bearing walls bored 50% or more -EC#2 per plans -Truss bracing per plans -conductors stapled to bottom of floor joists in unfinished basement shall be run either through bored holes in joists or on running boards. -Anchor all columns to floor -Joist hanger at floor joist above basement stair landing, not bearing enough on top plate -protection plate at DWV bedroom #4 closet bottom plate
Sewer Service Inspection - R Passed 10/7/2020 (9:30) 10/7/2020 10/07/2020
Water Service Inspection - R Passed 10/8/2020 (11:30) 10/8/2020 10/08/2020
All Rough Inspection - Residential Failed 10/9/2020 10/9/2020 10/09/2020
Misc
Corrective Action Required
10/05/2020
INSPECTION DENIED, MAINTAIN EROSION CONTROL SILT FENCE AT FRONT OF LOT, CLEAN MUD AND GRAVEL AT STREET IN FRONT OF LOT -Seal all top plate penetrations -Structural straps at all exterior walls and interior load bead bearing walls bored 50% or more -EC#2 per plans -Truss bracing per plans -conductors stapled to bottom of floor joists in unfinished basement shall be run either through bored holes in joists or on running boards. -Anchor all columns to floor -Joist hanger at floor joist above basement stair landing, not bearing enough on top plate -protection plate at DWV bedroom #4 closet bottom plate
Erosion Control Inspection Residential Failed 10/9/2020 10/9/2020 10/09/2020
Misc
Corrective Action Required
10/09/2020
INSPECTION DENIED, MAINTAIN EROSION CONTROL SILT FENCE AT FRONT OF LOT, CLEAN MUD AND GRAVEL AT STREET IN FRONT OF LOT
Driveway Inspection Partial 10/14/2020 (P.M.) 10/14/2020 10/14/2020
Misc
Informational
10/14/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Failed 10/20/2020 10/20/2020 10/20/2020
Misc
Corrective Action Required
10/09/2020
-Seal all top plate penetrations -EC#2 per plans -Anchor all columns to floor -Joist hanger at floor joist above basement stair landing, not bearing enough on top plate HOUSE INSULATED WITHOUT APPROVAL - REMOVE INSULATION COVER FROM ALL PLATE PENETRATIONS THROUGHOUT HOUSE TO ALLOW FOR INSPECTION
Driveway Inspection Passed 10/21/2020 10/21/2020 10/21/2020
All Rough Inspection - Residential Failed 10/27/2020 10/27/2020 10/27/2020
Misc
Corrective Action Required
10/20/2020
-Seal all top plate penetrations - basement -EC#2 per plans -Anchor all columns to floor
Sidewalk Inspection Partial 11/3/2020 (A.M.) 11/3/2020 11/03/2020
Misc
Informational
11/03/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Failed 11/10/2020 11/10/2020 11/10/2020
Misc
Corrective Action Required
10/27/2020
-Seal all top plate penetrations - basement -EC#2 per plans - (2) at garage per plans, install or remove Sheetrock stack if covering
Sidewalk Inspection Passed 11/10/2020 11/10/2020 11/11/2020
Misc
Informational
11/03/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Passed 11/11/2020 11/11/2020 11/11/2020
Misc
Resolved
11/11/2020
-Seal all top plate penetrations - basement -EC#2 per plans - (2) at garage per plans, install or remove Sheetrock stack if covering
Sidewalk Inspection Partial 12/1/2020 12/1/2020 12/01/2020
Misc
Informational
12/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 12/8/2020 12/8/2020 12/09/2020
Misc
Informational
12/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 1/13/2021 1/13/2021 01/13/2021
Misc
Corrective Action Required
01/13/2021
-Complete final grade and sod -Gutters and downspout required -Splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -Install deadbolt at front door -exposed NM at oven, install oven/cover -Install wall receptacle at master bath vanity -AFCI protection at washer circuit -Install light fixture at basement stairs closet
Occupancy Inspection - Codes Residential Temporary C of O 2/10/2021 2/10/2021 02/10/2021
Misc
Corrective Action Required
01/13/2021
-Complete final grade and sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation OK FOR TCO - TCO EXPIRES 3/10/21
Occupancy Inspection - Codes Residential Full C of O 3/9/2021 3/9/2021 03/09/2021
Misc
Resolved
03/09/2021
Plot Plan Inspection Passed 03/09/2021
Documents & Images
Date Uploaded File Type Document Name
06/03/2020 Application Form RR #86 - PERMIT APP
06/03/2020 86 RESERVE AT STONEY CREEK ROOF LAYOUT- signed
06/03/2020 400280
06/03/2020 LOT 86 FINAL
06/03/2020 RR #86 - Meadowbrook - Craftsman - Sheets- signed
06/05/2020 Plans APPROVED HOUSE PLANS
06/05/2020 Specifications APPROVED ROOF TRUSS PACKAGE
06/05/2020 Drawing APPROVED TRUSS LAYOUT
06/05/2020 Letter Codes Residential Plan Review
06/10/2020 Receipt Receipt for transaction:2020-002822
06/10/2020 Plot Plan APPROVED PLOT PLAN
06/10/2020 Letter DS Building Permit
07/24/2020 Letter INSPECTION SUMMARY
07/30/2020 86 Reserve at Stoney Creek - Footing Inspection
07/30/2020 Lot 86 Reserve at Stoney Creek - Wall Inspection
07/30/2020 Letter 86 Reserve at Stoney Creek - Footing Inspection
07/30/2020 Letter INSPECTION SUMMARY
08/04/2020 Letter INSPECTION SUMMARY
08/04/2020 Letter INSPECTION SUMMARY
10/05/2020 Letter INSPECTION SUMMARY
10/05/2020 Letter INSPECTION SUMMARY
10/05/2020 Letter INSPECTION SUMMARY
10/05/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
10/09/2020 Letter INSPECTION SUMMARY
10/09/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
10/21/2020 Letter INSPECTION SUMMARY
10/27/2020 Letter INSPECTION SUMMARY
11/03/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/18/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter INSPECTION SUMMARY
01/13/2021 Receipt Receipt for transaction:2021-000178
01/13/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter Codes Temporary Certificate of Occupancy
03/09/2021 Letter Field Certificate of Occupancy
03/09/2021 Letter Codes Final Certificate of Occupancy
03/09/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: