Permit Application Status

PRRES20201106


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201106
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
05/01/2020
05/05/2020
06/08/2021
Locations
Contacts
ROBERT A WASHAM CONSTRUCTION INC, Address:2058 NW SOUTH OUTER RD, Phone:(816) 224-5583  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
MARKV@ROBWASHAMHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 05/05/2020 05/04/2020
Kim Brennan
Misc
Corrective Action Required
05/01/2020

The property address must be on all pages of the drawings
07 Identify emergency escape openings from bedrooms
Corrective Action Required
05/01/2020

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) Please identify this for the master bedroom
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
05/01/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
05/01/2020

Identify roof covering material (IRC Section R905)
Plot Plan Review Approved 05/05/2020 05/04/2020
Kim Brennan
As-graded plot plan
Corrective Action Required
05/01/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Misc
Corrective Action Required
05/01/2020

Please provide cross section elevations for the berm and the swale.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,479.26 $1,479.26 Paid 05/04/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/04/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 05/04/2020
8331507-Sewer Connection Fee $540.00 $540.00 Paid 05/04/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 05/04/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 05/04/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/2/2020 (10:00) 6/2/2020 06/02/2020
Underslab Plumbing Inspection - Residential Passed 7/6/2020 7/6/2020 07/06/2020
Sewer Service Inspection - R Passed 7/6/2020 (9:45) 7/6/2020 07/06/2020
Water Service Inspection - R Passed 7/6/2020 (9:45) 7/6/2020 07/06/2020
Erosion Control Inspection Residential Failed 07/17/2020
Misc
Corrective Action Required
07/17/2020
-ADDRESS DEFICIENT EROSION CONTROL
All Rough Inspection - Residential Partial 8/13/2020 8/13/2020 08/13/2020
Miscellaneous Correction
Informational
08/13/2020
GARAGE PORTAL FRAMING EXTERIOR ONLY- STRAPPING AND NAILING PATTERN COMPLETE. -NO 5/8” ANCHOR BOLTS OR STRAPS ON INSIDE
Erosion Control Inspection Residential Passed 09/29/2020
Misc
Resolved
09/29/2020
-deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -remove trash from site -remove overgrown weeds and vegetation
All Rough Inspection - Residential Failed 9/30/2020 9/30/2020 09/30/2020
Misc
Corrective Action Required
09/30/2020
Inspection denied, city approved plans required to be on site for all inspections. Tried to call builder no answer
All Rough Inspection - Residential Failed 10/1/2020 10/1/2020 10/01/2020
Miscellaneous Correction
Informational
09/30/2020
GARAGE PORTAL FRAMING EXTERIOR ONLY- STRAPPING AND NAILING PATTERN COMPLETE. -NO 5/8” ANCHOR BOLTS OR STRAPS ON INSIDE
Misc
Corrective Action Required
10/01/2020
-Properly fasten second story east side exterior sheathing -Gas fireplace flue termination required to be 2’ above any portion of the building within 10’ due to vertical wall within 8’ of termination -unable to verify installation of anchor bolts, nuts & plate washers at portal opening -tighten all anchor bolts in garage -seal penetrations in sheet metal at ducts & vent in garage under cantilever -Address middle 1/3 notches in 2 x 10 floor joists with sistered 2x8 under master shower -Provide solid blocking at cantilevers and where joists are parallel with foundation above sub panel -in unfinished basement where conductors run at angles with joists it shall be permissible to secure cables not smaller than two 6 AWG or three 8 AWG conductors directly to the lower edges of the joists. Smaller cables shall be run either through bored holes in joists or on running boards. -Gas piping pressure test fail, minimum 10 psi for 15 minutes -Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 12” OC fastening -4 bearing studs required under LVL header, mudroom to living area cased opening -Missing LVL 3-pack joists from exterior wall to steel beam pantry/kitchen area per plan -3 Bearing studs required under LVL in great room at shelf location per plan -Missing LVL pack at master bath/hallway area per plan -Three studs under cantilever beam at stairway/bath, at bath wall -All headers to bear on minimum 2-2x4 per plan -Provide outlet box for oven -Fire block all top and bottom plate penetrations, kitchen & foyer -Complete bath exhaust duct and terminations per code -LVL 3-pack over stairway to loft per plan
Electrical Service Inspection Passed 10/1/2020 10/1/2020 10/01/2020
Gas Piping Inspection - Residential Failed 10/1/2020 10/1/2020 10/01/2020
Misc
Corrective Action Required
10/01/2020
Gas piping pressure test fail, minimum 10 psi for 15 minutes
Gas Service Inspection - Residential Failed 10/1/2020 10/1/2020 10/01/2020
All Rough Inspection - Residential Failed 10/9/2020 10/9/2020 10/09/2020
Miscellaneous Correction
Resolved
10/09/2020
GARAGE PORTAL FRAMING EXTERIOR ONLY- STRAPPING AND NAILING PATTERN COMPLETE. -NO 5/8” ANCHOR BOLTS OR STRAPS ON INSIDE
Misc
Corrective Action Required
10/01/2020
-Gas fireplace flue termination required to be 2’ above any portion of the building within 10’ due to vertical wall within 8’ of termination -Address middle 1/3 notches in 2 x 10 floor joists with sistered 2x8 under master shower -in unfinished basement where conductors run at angles with joists it shall be permissible to secure cables not smaller than two 6 AWG or three 8 AWG conductors directly to the lower edges of the joists. Smaller cables shall be run either through bored holes in joists or on running boards. -Gas piping pressure test fail, minimum 10 psi for 15 minutes -Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 12” OC fastening -Missing LVL pack at master bath/hallway area per plan -Three studs under cantilever beam at stairway/bath, at bath wall -Fire block all top and bottom plate penetrations, kitchen & foyer -Complete bath exhaust duct terminations per code
Gas Piping Inspection - Residential Failed 10/9/2020 10/9/2020 10/09/2020
Misc
Corrective Action Required
10/01/2020
Gas piping pressure test fail, minimum 10 psi for 15 minutes
Gas Service Inspection - Residential Failed 10/9/2020 10/9/2020 10/09/2020
All Rough Inspection - Residential Passed 10/30/2020 10/30/2020 10/30/2020
Misc
Resolved
10/30/2020
Ok to insulate and rock
Gas Piping Inspection - Residential Passed 10/30/2020 10/30/2020 10/30/2020
Misc
Resolved
10/30/2020
Gas piping pressure test fail, minimum 10 psi for 15 minutes
Gas Service Inspection - Residential Passed 10/30/2020 10/30/2020 10/30/2020
Driveway Inspection Passed 2/3/2021 (Ready Now) 2/3/2021 02/03/2021
Misc
Informational
02/03/2021
On Wednesday, 2-03-2021. I performed a drive approach inspection. Drive passes city standards.
Occupancy Inspection - Codes Residential Failed 2/19/2021 2/19/2021 02/19/2021
Misc
Corrective Action Required
02/19/2021
-Maintenance of erosion control methods is required until sod is in place -Remove trash and construction debris from site -final grade, sod and an as graded plot plan required -Provide building address, minimum 4” height, 1/2” stroke, on contrasting background and in an illuminated area -provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36” from foundation -Install exterior door hardware -Garage/dwelling separation door required to self close and self latch -Complete plumbing installation, main level bathrooms -Complete electrical installation above fireplace
Plot Plan Inspection Passed 3/5/2021 03/04/2021
Occupancy Inspection - Codes Residential Temporary C of O 3/5/2021 3/5/2021 03/04/2021
Misc
Corrective Action Required
02/19/2021
-Maintenance of erosion control methods is required until sod is in place -Downspouts and sump piping to discharge minimum 36” from foundation TCO VALID THROUGH 04/04/2021
Erosion Control Inspection Residential Failed 03/17/2021
Misc
Corrective Action Required
07/17/2020
Erosion control methods require continuous maintenance. Re-establish methods until sod is in place
Miscellaneous Inspection Failed 04/07/2021
Misc
Corrective Action Required
04/07/2021
-The temporary certificate of occupancy has expired at this address. A permit extension request must be submitted in writing with the expected date of completion. After the request is submitted, please schedule an occupancy inspection so the inspector may review current site conditions and either approve or deny the request. -Maintenance of erosion control methods is required until sod is in place. Streets and sidewalks must remain free of silt and debris.
Occupancy Inspection - Codes Residential Temporary C of O 04/07/2021
Misc
Corrective Action Required
03/04/2021
-Maintenance of erosion control methods is required until sod is in place -Downspouts and sump piping to discharge minimum 36” from foundation TCO EXTENSION VALID THROUGH 05/07/2021
Misc
Informational
04/07/2021
Builder is working with the city regarding burm/swale requirement rear of lot 4/7/21 JM
Plot Plan Inspection Passed 5/6/2021 05/06/2021
Occupancy Inspection - Codes Residential Temporary C of O 05/12/2021
Misc
Corrective Action Required
04/07/2021
-Maintenance of erosion control methods is required until sod is in place -Downspouts and sump piping to discharge minimum 36” from foundation TCO EXTENSION VALID THROUGH 05/07/2021
Misc
Informational
04/07/2021
Miscellaneous Inspection Passed 06/08/2021
Misc
Resolved
06/08/2021
-The temporary certificate of occupancy has expired at this address. A permit extension request must be submitted in writing with the expected date of completion. After the request is submitted, please schedule an occupancy inspection so the inspector may review current site conditions and either approve or deny the request. -Maintenance of erosion control methods is required until sod is in place. Streets and sidewalks must remain free of silt and debris.
Erosion Control Inspection Residential Passed 06/08/2021
Occupancy Inspection - Codes Residential Full C of O 6/8/2021 6/8/2021 06/08/2021
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.