Summary
PRRES20201007
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK SUSPENDED SLAB
04/21/2020
04/28/2020
11/18/2020
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
DENNIS@SABHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/23/2020 04/23/2020
Kim Brennan
Lot elevations
Corrective Action Required
04/21/2020

Existing and finish elevations at all property corners must be provided on the plot plan. Please provide these elevations for the front south corner and rear north corner
Basement egress
Corrective Action Required
04/21/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
04/21/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Please shoe MBOE of 933.33 as shown on the MDP for the rear left corner of the building.
As-graded plot plan
Corrective Action Required
04/21/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 04/23/2020 04/21/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $988.19 $988.19 Paid 04/28/2020
Right of Way Permit Fee $80.00 $80.00 Paid 04/28/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/28/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 04/28/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 04/28/2020
Water Meter Fee $425.02 $425.02 Paid 04/28/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 5/20/2020 5/20/2020 at 8:24 AM 05/20/2020
Piers/Caissons Inspection - Residential Failed 6/11/2020 (2:00) 6/11/2020 06/11/2020
Misc
Corrective Action Required
06/11/2020
- PUMP WATER OUT OF PIERS - - PIERS TO TERMINATE AT A POINT 36" MINIMUM BELOW FINISHED GRADE -
Suspended Slab Inspection Failed 6/11/2020 (2:00) 6/11/2020 06/11/2020
Misc
Corrective Action Required
06/11/2020
- TIE # 4 BARS @ 12" OC E/W ON 1 1/2 CHAIRS
Piers/Caissons Inspection - Residential Passed 6/15/2020 (1:00) 6/15/2020 06/15/2020
Misc
Resolved
06/15/2020
(2) 245 X 36 DECK PIERS
Suspended Slab Inspection Passed 6/15/2020 (1:00) 6/15/2020 06/15/2020
Misc
Resolved
06/15/2020
- #4 BARS @ 12" OC E/W ON 1 1/2 CHAIRS
Sewer Service Inspection - R Partial 7/7/2020 (2:30) 7/7/2020 07/07/2020
Misc
Informational
07/07/2020
- PARTIAL SEWER MIDDLE OF FRONT YARD -
Sewer Service Inspection - R Passed 7/8/2020 (9:30) 7/8/2020 07/08/2020
Misc
Informational
07/07/2020
- PARTIAL SEWER MIDDLE OF FRONT YARD -
Water Service Inspection - R Passed 7/8/2020 (1:00) 7/8/2020 at 1:10 PM 07/08/2020
Gas Piping Inspection - Residential Passed 7/22/2020 7/22/2020 07/22/2020
Gas Service Inspection - Residential Passed 7/22/2020 7/22/2020 07/22/2020
Electrical Service Inspection Passed 7/22/2020 7/22/2020 07/22/2020
All Rough Inspection - Residential Failed 7/22/2020 7/22/2020 07/22/2020
Misc
Corrective Action Required
07/22/2020
- NO FOOTING INSPECTION ON RECORD PROVIDE 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR - - ADDRESS RAFTERS LANDING ON BLOCKS THROUGHOUT - - ADDRESS SUSPENDED SLAB - - NAIL JOIST HANGER ABOVE FRONT DOOR - - TIGHTEN ANCHOR BOLTS THROUGHOUT - - PROVIDE ANCHOR BOLTS WITHIN 12" OF PLATE BREAK THROUGHOUT - - PROVIDE NUT & WASHER ANCHOR BOLT UNDER FAMILY ROOM WINDOWS - - PROVIDE TENSION STRAP PER PLAN HEADER TO JACK STUD PFH PORTAL FRAME GARAGE - - PROVIDE NAIL GUARDS ELECTRICAL CORNER OF GARAGE NEAR SERVICE PANEL & DRYER BOX - - PROVIDE PURLIN PER PLAN ABOVE 20 MIN DOOR - - PROVIDE PROTECTION FOR WIRING NEAR ATTIC ACCESS - - PROVIDE MIDPOINT SUPPORT ALL 2" OR SMALLER DWV THROUGHOUT - - SEAL TOP PLATE ELECTRICAL PENETRATIONS MASTER BATH - - FIRE BLOCK DEAD SPACES AT FIRE PLACE - - PROVIDE JOIST HANGERS @ LVL ABOVE STAIRWAY - - PROVIDE VERTICAL FIRE BLOCK EVERY 10' AT BASEMENT FURR OUT - - SEAL ( INSULATE) BEAM POCKET WEBS - - PROVIDE SIMPSON GUSSET ANGLE & NOTCH OVER SLEEPER PER STAIR STRINGER DETAIL -
Footing Inspection - Residential Passed 5/1/2020 07/24/2020
Misc
Informational
07/24/2020
- 3RD PARTY FOOTING SIGNED & SEALED BY DAVID P AINSWORTH - - UFER LOCATION NOT NOTED IN COMMENTS -
All Rough Inspection - Residential Failed 7/28/2020 7/28/2020 07/28/2020
Misc
Corrective Action Required
07/22/2020
- ADDRESS RAFTERS LANDING ON BLOCKS THROUGHOUT - - PROVIDE ANCHOR BOLTS WITHIN 12" OF PLATE BREAK NEAR UFER IN UNFINISHED AREA BEHIND STAIRS -
All Rough Inspection - Residential Passed 7/30/2020 7/30/2020 07/30/2020
Misc
Resolved
07/30/2020
Driveway Inspection Partial 8/27/2020 8/27/2020 08/27/2020
Misc
Informational
08/27/2020
The approach appeared to have 4 " of compacted rock and appeared to have rooom for 6" of concrete. There is no sidewalk on this side of the road. They have been approved to pour the approach.
Driveway Inspection Passed 9/1/2020 09/03/2020
Misc
Informational
08/27/2020
The approach appeared to have 4 " of compacted rock and appeared to have rooom for 6" of concrete. There is no sidewalk on this side of the road. They have been approved to pour the approach.
Misc
Informational
09/02/2020
Finished driveway meets LS specs. RP 9-2-20
Plot Plan Inspection Passed 10/19/2020 10/19/2020
Occupancy Inspection - Codes Residential Failed 11/11/2020 11/11/2020 11/11/2020
Misc
Corrective Action Required
11/11/2020
-Seal top and side of AC disconnect, top and side of electric meter enclosure and all exterior penetrations -Remove screen from clothes dryer exhaust termination -Exterior lighting fixture at basement man door required to be a fixture where the bulb is not accessible where installed below 8’ AFF -Address loose guard rail at deck and loose handrail at garage stairs -Label single receptacle dedicated circuits in unfinished basement and garage as non-GFCI protected, label at receptacles -Provide breaker lockout device for hardwired appliances not insight of electric panel
Erosion Control Inspection Residential Passed 11/11/2020
Occupancy Inspection - Codes Residential Full C of O 11/18/2020 11/18/2020 11/18/2020
Misc
Resolved
11/18/2020
-Seal top and side of AC disconnect, top and side of electric meter enclosure and all exterior penetrations -Remove screen from clothes dryer exhaust termination -Exterior lighting fixture at basement man door required to be a fixture where the bulb is not accessible where installed below 8’ AFF -Address loose guard rail at deck and loose handrail at garage stairs -Label single receptacle dedicated circuits in unfinished basement and garage as non-GFCI protected, label at receptacles -Provide breaker lockout device for hardwired appliances not insight of electric panel
Deck Final Inspection - Residential Passed 11/18/2020
Documents & Images
Date Uploaded File Type Document Name
04/21/2020 Letter Permit Application
04/21/2020 Letter License Tax Form
04/21/2020 Plans Approved Drawings
04/21/2020 Letter Codes Residential Plan Review
04/23/2020 Plot Plan Approved Plot Plan
04/28/2020 Receipt Receipt for transaction: 2020-001751
04/28/2020 Letter DS Building Permit
05/20/2020 Letter INSPECTION SUMMARY
06/11/2020 Letter INSPECTION SUMMARY
06/11/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/23/2020 128 NW Mackenzie Dr LSMO Winterset Valley Lot 1469 SAB Homes 3rd Party Footing Inspection Report 5-1-20
07/24/2020 Letter INSPECTION SUMMARY
07/28/2020 Letter INSPECTION SUMMARY
07/30/2020 Letter DW Framing Inspection Letter WV1469 Solaia 128 NW Mackenzie Dr
07/30/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter DE-Daily Inspection Summary
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/24/2020 Engineer Report/Study 20.2084 128 NW McKenzie Engineer Letter (003)
10/05/2020 Engineer Report/Study 20.2084 128 NW McKenzie Engineer Letter (003)
10/16/2020 Plot Plan As Graded Plot Plan
10/19/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/18/2020 Letter Codes Final Certificate of Occupancy
11/18/2020 Letter Field Certificate of Occupancy
11/18/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home