Permit Application Status

PRRES20200871


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200871
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
04/06/2020
04/16/2020
01/12/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 04/09/2020 04/10/2020
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
04/07/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) Please show smoke detector in the unfinished basement.
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
04/07/2020

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Approved 04/09/2020 04/08/2020
Kim Brennan
City infrustructure
Corrective Action Required
04/07/2020

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. Please show storm inlet located on the south west side of the property corner by the fire hydrant Also, legend for fire hydrant and water valve is missing
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $962.91 $962.91 Paid 04/16/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/16/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/16/2020
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 04/16/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 04/16/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 04/16/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 04/16/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/7/2020 (3:00) 5/7/2020 05/07/2020
Underslab Plumbing Inspection - Residential Failed 5/29/2020 5/29/2020 05/29/2020
Misc
Corrective Action Required
05/29/2020
- NO INSPECTION PERFORMED - - UNABLE TO INSPECT PLUMBING DUE TO COVER FROM SEVERAL INCHES OF WATER AND MUD COVER FROM HEAVY RAINS. EITHER PUMP OUT WATER OR WAIT UNTIL CONDITIONS IMPROVE FOR COMEPLETE INSPECTION BEFORE RESCHEDULING -
Underslab Plumbing Inspection - Residential Passed 6/5/2020 6/5/2020 06/05/2020
Misc
Resolved
06/05/2020
Sewer Service Inspection - R Passed 6/16/2020 (11:30) 6/16/2020 06/16/2020
Water Service Inspection - R Passed 6/17/2020 (11:00) 6/17/2020 06/17/2020
Electrical Service Inspection Failed 8/10/2020 8/10/2020 08/10/2020
Misc
Corrective Action Required
08/10/2020
- UFER ground required
Gas Piping Inspection - Residential Passed 8/10/2020 8/10/2020 08/10/2020
Gas Service Inspection - Residential Passed 8/10/2020 8/10/2020 08/10/2020
All Rough Inspection - Residential Failed 8/10/2020 8/10/2020 08/10/2020
Misc
Corrective Action Required
08/10/2020
- Garage PFH per plans - Anchor bolts within 12” of plate break in garage - Complete all bath exhaust fan discharge - Secure all DWV 2” or less at mid point - Seal all penetrations through air returns and plenums - Snow block in pantry - Secure pex at chase in living room per manufacturer listed product - (5) studs per plans at pantry/garage corner at lvl bearing - Truss hangers per plans - Connect top plates at top stair landing at 2x6 to 2x4 wall - EC#2 per plans - Structural strap at top plate basement bored for DWV in bearing wall bedroom #3, master bath - Secure all steel columns to floor in basement - Joist hangers required at cantilever joist connection to triple floor joist in basement, over 4’ - Joist hangers required at floor joist connection to dbl joist header at cantilever, over 4’ - 3” steel column missing at beam, pier location “ B” per plans, SE side basement - UFER ground required
Electrical Service Inspection Passed 8/14/2020 8/14/2020 08/14/2020
Misc
Resolved
08/14/2020
All Rough Inspection - Residential Failed 8/14/2020 8/14/2020 08/14/2020
Misc
Corrective Action Required
08/14/2020
- Garage PFH per plans - Truss hangers per plans - front porch, back porch - Structural strap at top plate bored for DWV in bearing wall bedroom #3
All Rough Inspection - Residential Passed 8/20/2020 8/20/2020 08/20/2020
Misc
Resolved
08/20/2020
Driveway Inspection Partial 8/28/2020 8/28/2020 08/28/2020
Misc
Informational
08/28/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 8/28/2020 8/28/2020 08/28/2020
Misc
Informational
08/28/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 9/3/2020 9/3/2020 09/04/2020
Misc
Informational
08/28/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 9/3/2020 9/3/2020 09/04/2020
Misc
Informational
08/28/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 11/25/2020 11/25/2020 11/25/2020
Misc
Corrective Action Required
11/25/2020
PROVIDE LOCK BOX CODE AT ALL INSPECTIONS. --INSTALL GUARD AROUND PATIO , OVER 30". - INSPECT ALL EXTERIOR ITEMS AT RE-INSPECTION. -BASEMENT HANDRAILS UNDER 34". --LOWER FLIGHT OPEN ON BASEMENT SIDE, INSTALL ROCK OR PLYWOOD ON WALL. --BOTTOM STEP FROM EGRESS LADDER TO GRAVEL CAN BE NO MORE THAN 18". --INSTALL DISHWAHER & RANGE WITH ANTI TIP. -- SEAL BOTTOM OF BOX OUT IN GARAGE. --SECURE AND TIGHTEN UFER GROUND IN GARAGE. PROTECT GEC AT WALL. INSTALL APPROVED FIRE SEPERATION AT BASEMENT FROM GARAGAE AT THE UFER GROUND. -- BREAK OF SET SCREW AT ANTI-SIPHON HOSE BIB BASMENT.
Occupancy Inspection - Codes Residential Failed 12/28/2020 12/28/2020 12/28/2020
Misc
Corrective Action Required
11/25/2020
-OBTAIN LAWN IRRIGATION SYSTEM PERMIT -SPLASH BLOCKS AT ALL DOWNSPOUTS -SEAL PENETRATIONS IN SIDING, SEAL ALONG TOP OF METER CAN AND AC DISCONNECT -SECURE AC ELECTRICAL WHIP WITHIN 12” OF DISCONNECT -UNCOVER SOD FROM WATER METER LID -STAIRS REQUIRED FROM PATIO TO GRADE, CURRENT RISE MORE THAN 7 3/4”
Plot Plan Inspection Passed 1/12/2021 1/12/2021 01/12/2021
Occupancy Inspection - Codes Residential Full C of O 1/12/2021 1/12/2021 01/12/2021
Misc
Resolved
01/12/2021
Documents & Images
Date Uploaded File Type Document Name
04/06/2020 Letter Permit Application
04/08/2020 Letter Codes Residential Plan Review
04/08/2020 Plot Plan Plot Plan
04/08/2020 Letter Roof Truss Package
04/08/2020 Plans 1st floor Roof Layout
04/08/2020 Plans 2nd floor Roof Layout
04/10/2020 Plans Approved Drawings
04/16/2020 Receipt Receipt for transaction:2020-001560
04/16/2020 Letter DS Building Permit
05/07/2020 Letter INSPECTION SUMMARY
05/29/2020 Letter INSPECTION SUMMARY
06/05/2020 Letter INSPECTION SUMMARY
06/16/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/14/2020 Letter INSPECTION SUMMARY
08/14/2020 Letter INSPECTION SUMMARY
08/20/2020 Letter INSPECTION SUMMARY
08/28/2020 Letter INSPECTION SUMMARY
08/28/2020 Letter INSPECTION SUMMARY
09/04/2020 Letter INSPECTION SUMMARY
09/04/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
12/28/2020 Letter INSPECTION SUMMARY
01/12/2021 Letter INSPECTION SUMMARY
01/12/2021 Letter Field Certificate of Occupancy
01/12/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home