Permit Application Status

PRRES20200388


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200388
Building Permit - Residential
Certificate of Occupancy
SAB CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - SUSPENDED SLAB - COVERED DECK
02/18/2020
02/27/2020
08/25/2020
01/05/2021
Locations
Contacts
SAB CONSTRUCTION LLC, Address:PO BOX 942, Phone:(816) 524-3855  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
CURTIS@SABHOMES.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/02/2020 02/27/2020
Development Center
As-graded plot plan
Corrective Action Required
02/27/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 03/02/2020 02/27/2020
Development Center
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
02/27/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) UNFINISHED BASEMENT SQUARE FOOTAGE IS DIFFERENT FROM THE APPLICATION PLEASE CONFIRM CORRECT SQUARE FOOTAGE.
Plot Plan Review Rejected 02/20/2020 02/20/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
02/20/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Rejected 02/20/2020 02/20/2020
Dylan Eppert
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
02/20/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) UNFINISHED BASEMENT SQUARE FOOTAGE IS DIFFERENT FROM THE APPLICATION PLEASE CONFIRM CORRECT SQUARE FOOTAGE.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,193.09 $1,193.09 Paid 02/27/2020
8331507-Sewer Connection Fee $420.00 $420.00 Paid 02/27/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 02/27/2020
Water Meter Fee $425.02 $425.02 Paid 02/27/2020
Right of Way Permit Fee $80.00 $80.00 Paid 02/27/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/27/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/12/2020 (1:30) 3/12/2020 at 1:40 PM 03/12/2020
Water Service Inspection - R Partial 3/30/2020 03/30/2020
Sewer Service Inspection - R Passed 3/30/2020 at 1:00 PM 03/30/2020
Water Service Inspection - R Passed 3/31/2020 at 9:05 AM 03/31/2020
Erosion Control Inspection Residential Failed 4/9/2020 04/09/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/09/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 4/9/2020 4/9/2020 at 9:10 AM 04/09/2020
Suspended Slab Inspection Passed 5/29/2020 5/29/2020 at 1:00 PM 05/29/2020
All Rough Inspection - Residential Failed 7/22/2020 7/22/2020 at 7:40 AM 07/22/2020
Misc
Corrective Action Required
07/22/2020
FRAMING: -Fb foyer wall from roof -Install hanger support for foyer lvl beams -Support rafters to 2x10 purlin with hangers or blocking underneath rafters -Shim gap at front porch beam support inside front bedroom -Front bedroom gable wall studs not continuous -Support ridge above front bedroom -Anchor garage portal walls sill plates per code -Have engineer address non-continuous 2x4 studs in exterior wall exceeding 12 ft in garage and front bedroom -Support hip rafters at ridge above great room -Support underneath master bedroom ceiling beam point load to I beam below -Nail corner studs per code -Fb fireplace space from roof. Use 3/4” sheathing or other approved materials -Fb double stud wall in basement vertically every ten ft of less -Toe nail joists to basement sill plate and top plates with 3-10d or 4-8d box nails ELECTRICAL: -Protect wiring within six ft of attic access -Protect wiring at rear dining area where located within 1.25” of framing surface **OK TO INSULATE
Electrical Service Inspection Passed 7/22/2020 7/22/2020 07/22/2020
Gas Service Inspection - Residential Passed 7/22/2020 7/22/2020 07/22/2020
All Rough Inspection - Residential Failed 7/24/2020 7/24/2020 at 8:00 AM 07/24/2020
Misc
Corrective Action Required
07/22/2020
FRAMING: -Fb foyer wall from roof -Support rafters to 2x10 purlin with hangers or blocking underneath rafters -Have engineer address non-continuous 2x4 studs in exterior wall exceeding 12 ft in garage and front bedroom -Fb fireplace space from roof. -Fb double stud wall in basement vertically every ten ft of less **OK TO INSULATE
All Rough Inspection - Residential Passed 8/7/2020 8/7/2020 08/07/2020
Misc
Resolved
08/07/2020
-Have engineer address non-continuous 2x4 studs in exterior wall exceeding 12 ft in garage and front bedroom
Driveway Inspection Partial 9/23/2020 (Ready Now) 9/23/2020 09/23/2020
Misc
Informational
09/23/2020
Driveway - Forms and materials passed pre-inspection.
Driveway Inspection Passed 9/28/2020 9/28/2020 09/28/2020
Misc
Informational
09/23/2020
Driveway - Forms and materials passed pre-inspection.
Misc
Informational
09/28/2020
Driveway - Passed final inspection.
Occupancy Inspection - Codes Residential Failed 11/4/2020 11/4/2020 11/04/2020
Misc
Corrective Action Required
11/04/2020
**INSTALL EROSION CONTROL ALONG THE STREET BEFORE TCO CAN BE ISSUED -Provide address near source of light -Provide guardrail at stoop at open side where the edge is more than 30” above grade, as measured 36” out from edge -As-graded plot plan -Final grade, sod, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, etc -Secure AC whip within 12” of disconnect -Install tamper-proof caps at AC valves -Drive the grounding rod down below ground, with the clamp buried under ground -Deck: nail joist hanger near post; provide two lag screws at each ledger board break -All dedicated non-gfci receptacles in garage and unfinished basement to be identified (label, marking, etc) -Install face plates for receptacle outlets in garage -Fb garage wall penetrations under sink -Complete installing cooktop -Install breaker lock for oven, cooktop, and kitchen hood -Provide dedicated single plug receptacle for the alarm and future water softener or provide gfci protection -Door to lower garage not self-closing -Label breakers in sub panel
Occupancy Inspection - Codes Residential Temporary C of O 11/6/2020 11/6/2020 11/06/2020
Misc
Corrective Action Required
11/04/2020
-Final grade per plot plan, sod, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level
Erosion Control Inspection Residential Passed 11/06/2020
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/06/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Plot Plan Inspection Passed 1/5/2021 01/05/2021
Occupancy Inspection - Codes Residential Full C of O 1/5/2021 01/05/2021
Misc
Resolved
01/05/2021
-Final grade per plot plan, sod, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level
Documents & Images
Date Uploaded File Type Document Name
02/20/2020 Letter Codes Residential Plan Review
02/27/2020 Receipt Receipt for transaction: 2020-000863
02/27/2020 Letter DS Building Permit
03/12/2020 Letter INSPECTION SUMMARY
03/30/2020 Letter INSPECTION SUMMARY
03/30/2020 Letter INSPECTION SUMMARY
03/31/2020 Letter INSPECTION SUMMARY
04/09/2020 Letter INSPECTION SUMMARY
05/29/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/24/2020 Letter INSPECTION SUMMARY
08/05/2020 Engineer Report/Study Untitled000
08/07/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter INSPECTION SUMMARY
09/28/2020 Letter INSPECTION SUMMARY
11/04/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter Codes Temporary Certificate of Occupancy
11/06/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter Codes Residential Plan Review
11/06/2020 Letter INSPECTION SUMMARY
01/04/2021 Plot Plan APPROVED AS-BUILT
01/05/2021 Letter Codes Final Certificate of Occupancy
01/05/2021 Letter Field Certificate of Occupancy
01/05/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents