Permit Application Status

PRRES20193663


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193663
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY PARTIALLY FINISHED BASEMENT COVERED DECK
12/23/2019
01/10/2020
06/24/2020
02/27/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 12/27/2019 01/09/2020
Steve Conrick
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
12/27/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) lower level bedrooms missing smoke detectors inside rooms and combo detectors outside rooms missing combo detector outside of bedrooms
Plot Plan Review Approved 12/27/2019 01/09/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,111.12 $1,111.12 Paid 01/10/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/10/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/10/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 01/10/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 01/10/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 01/10/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/11/2020 (11:00) 2/11/2020 02/11/2020
Misc
Informational
02/11/2020
Drilled piers already poured 2/11/20 11:12 Footing ok to pour
Piers/Caissons Inspection - Residential Passed 2/7/2020 02/14/2020
Underslab Plumbing Inspection - Residential Passed 4/13/2020 4/13/2020 04/13/2020
Sewer Service Inspection - R Passed 5/7/2020 05/07/2020
Water Service Inspection - R Passed 6/2/2020 (10:15) 6/2/2020 06/02/2020
Erosion Control Inspection Residential Failed 06/04/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/04/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Passed 6/9/2020 6/9/2020 06/09/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/04/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 7/9/2020 7/9/2020 07/09/2020
Miscellaneous Correction
Corrective Action Required
07/09/2020
-ANCHOR BOLTS TO BE IN MIDDLE 3RD OF PLATE-GARAGE -TIGHTEN ANCHOR BOLTS IN GARAGE -STUDS NOTCHED GREATER THAN 25%-GARAGE -NAIL JOIST LAP CONNECTIONS IN GARAGE -FIRE BLOCK BEAMS IN GARAGE -SLOPE DWV VENT PIPE TOWARD DRAINS -STRAP TOP PLATE IN BATHROOM BY GARAGE -NAIL BOTTOM PLATE AT DOORWAY IN OFFICE -GARAGE CIRCUIT TO BE DEDICATED TO GARAGE ONLY/ KITCHEN CIRCUITS TO SERVE KITCHEN ONLY -PATHCH HOLE/ FIRE STOP IN FLOOR OF PANTRY -MISSING JOIST HANGERS IN OWNERS CLOSET -SEAL UPWARD PENETRATION IN MASTER BATH PLATE -FIRE BLOCK TUB TRAP IN MASTER BATH -MISSING NAILS IN JOIST HANGERS MASTER BED -MISSING ALL LIB -MISSING EC2 ALL LOCATIONS -MISSING (4) 2X6 AT STOOP -STRAP PLATE AT GREAT ROOM LVL HEADER -PROVIDE LATERAL SUPPORT FOR LVLS AND GIRDERS IN GREAT ROOM -SOLID BLOCK CEILING JOISTS AT COVERED DECK -MISSING (3) 2X4 AT OFFICE 2 -PROVIDE COLLAR TIES ABOVE STOOP -PROVIDE ATTIC ACCESS IN OWNERS CLOSET -PROVIDE HORIZONTAL FIRESTOP AT STAIRS/FUROUT WALL -PROVIDE HANGERS AND THRUST BLOCKS AT STAIR STRINGERS PER PLANS -ANCHOR BOTTOM PLATES IN BASEMENT-MECHANICAL ROOM -PROVIDE SOLID BLOCKING ABOVE BEAM -SEAL GAP IN FLOOR BY EGRESS DOOR -FIRE STOP DEAD SPACES BED 4 -MISSING JOIST HANGERS AT DECK -MISSING LEDGER BOLTS AND ALL BOLT CONNECTIONS AT DECK -POSTS OVER NOTCHED AND NOT PER PLAN S3.0 -BLOCKING OF JOISTS PARALLEL TO FOUNDATION PER S2.0
Gas Service Inspection - Residential Passed 07/09/2020
Electrical Service Inspection Passed 07/09/2020
Gas Piping Inspection - Residential Passed 07/09/2020
All Rough Inspection - Residential Failed 7/16/2020 7/16/2020 07/16/2020
Miscellaneous Correction
Corrective Action Required
07/09/2020
****DO NOT SHEET ROCK**** -MISSING EC1 ALL LOCATIONS
All Rough Inspection - Residential Passed 7/17/2020 7/17/2020 07/17/2020
Miscellaneous Correction
Resolved
07/17/2020
****DO NOT SHEET ROCK**** -MISSING EC1 ALL LOCATIONS
Driveway Inspection Passed 8/12/2020 8/12/2020 08/12/2020
Misc
Informational
08/12/2020
On Wednesday, 8-12-2020. I performed a driveway inspection and found the forming and sub-grade to meet city standards and passes inspection.
Erosion Control Inspection Residential Passed 10/09/2020
Misc
Resolved
10/09/2020
-Deficient erosion control, must be in compliance within two days or stop or order will be issued. Erosion control front of house requires maintenance, erosion control required at rear property line. -Remove debris from curb/gutter immediately
Plot Plan Inspection Failed 10/27/2020
Misc
Corrective Action Required
10/27/2020
-5’ sidewalk required per approved plot plan -locate and expose manhole in north rear yard corner as shown on plot plan -final grade per approved plot plan
Occupancy Inspection - Codes Residential Failed 10/27/2020 10/27/2020 10/27/2020
Misc
Corrective Action Required
10/27/2020
-5’ sidewalk shown on plot plan -Final grade per approved plot and sod -Downspouts and sump piping to discharge minimum 36 inches from foundation -Remove trash and construction debris from interior and exterior -Seal all exterior penetrations -Label dedicated circuits at receptacles as non-GFCI protected in garage and unfinished basement area -Receptacle outlet box above fireplace cannot be set back from the non-combustible finished surface more than 1/4” -Install all outlet plate covers -Both 20A microwave circuits require AFCI protection
Occupancy Inspection - Codes Residential Temporary C of O 11/2/2020 11/2/2020 11/02/2020
Misc
Corrective Action Required
10/27/2020
-5’ sidewalk required as shown on plot plan -Final grade per approved plot and sod -Downspouts and sump piping to discharge minimum 36 inches from foundation TCO valid through 12/02/2020
Occupancy Inspection - Codes Residential Temporary C of O 11/23/2020 11/23/2020 11/23/2020
Misc
Corrective Action Required
11/02/2020
- No sidewalk inspection on record, contact Development Services to resolve this issue TCO valid through 12/02/2020
Erosion Control Inspection Residential Passed 11/23/2020
Misc
Resolved
11/23/2020
-Deficient erosion control, must be in compliance within two days or stop or order will be issued. Erosion control front of house requires maintenance, erosion control required at rear property line. -Remove debris from curb/gutter immediately
Deck Final Inspection - Residential Passed 11/23/2020
Plot Plan Inspection Passed 11/23/2020
Misc
Resolved
11/23/2020
-5’ sidewalk required per approved plot plan -locate and expose manhole in north rear yard corner as shown on plot plan -final grade per approved plot plan
Occupancy Inspection - Codes Residential Failed 05/18/2021
Misc
Corrective Action Required
11/23/2020
- No sidewalk inspection on record, contact Development Services to resolve this issue TCO valid through 12/02/2020
Misc
Corrective Action Required
05/18/2021
The temporary certificate of occupancy has expired at this address. If remaining correction items are complete please schedule an occupancy inspection. If remaining correction items are not complete a permit extension request must be submitted in writing with the expected date of completion.
Sidewalk Inspection Passed 11/6/2020 11/6/2020 05/18/2021
Misc
Informational
05/18/2021
On Tuesday, 5-18-2021. A final inspection was preformed for city sidewalk and passed all city requirements.
Documents & Images
Date Uploaded File Type Document Name
12/27/2019 Letter Codes Residential Plan Review
01/10/2020 Receipt Receipt for transaction: 2020-000132
01/10/2020 Letter DS Building Permit
01/10/2020 Plot Plan DOC011020-002
02/11/2020 Letter INSPECTION SUMMARY
02/13/2020 Engineer Report/Study 1908 SW River Run Dr_PIER INSP_2020-02-07
04/13/2020 Letter INSPECTION SUMMARY
04/16/2020 Engineer Report/Study Final_2020.04.14_GBSlab_LSMO_Concrete Design
05/07/2020 Letter INSPECTION SUMMARY
06/02/2020 Letter INSPECTION SUMMARY
06/04/2020 Letter INSPECTION SUMMARY
06/04/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
07/09/2020 Letter INSPECTION SUMMARY
07/09/2020 Letter INSPECTION SUMMARY
07/09/2020 Letter INSPECTION SUMMARY
07/09/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
07/17/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
10/09/2020 Letter INSPECTION SUMMARY
10/26/2020 Letter INSPECTION SUMMARY
10/27/2020 Letter INSPECTION SUMMARY
10/27/2020 Letter INSPECTION SUMMARY
11/02/2020 Letter Codes Temporary Certificate of Occupancy
11/23/2020 Letter Codes Temporary Certificate of Occupancy
11/23/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home