Permit Application Status

PRRES20193662


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193662
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK MONTICELLO LANDSCAPE REQUIREMENTS
12/23/2019
01/03/2020
06/24/2020
07/27/2020
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
DAVE@DAVERICHARDSHOMES.COM  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
BLUE VALLEY HEATING & COOLING LLC, Address:P O BOX 241, Phone:(816) 867-5122  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 12/27/2019 01/02/2020
Steve Conrick
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
12/27/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) DETECTOR OUTSIDE MBR NEEDS TO BE COMBO OR SMOKE AND CARBON DETECTOR
Plot Plan Review Approved 12/27/2019 12/27/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,062.57 $1,062.57 Paid 01/03/2020
Right of Way Permit Fee $80.00 $80.00 Paid 01/03/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/03/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 01/03/2020
Water Meter Fee $425.02 $425.02 Paid 01/03/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 01/03/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 2/18/2020 (2:00) 2/18/2020 02/18/2020
Underslab Plumbing Inspection - Residential Passed 2/19/2020 at 1:50 PM 02/19/2020
Water Service Inspection - R Passed 2/19/2020 (2:15) 2/19/2020 at 2:05 PM 02/19/2020
Electrical Service Inspection Passed 5/1/2020 5/1/2020 05/01/2020
Gas Service Inspection - Residential Failed 5/1/2020 5/1/2020 05/01/2020
Misc
Corrective Action Required
05/01/2020
-Not ready
All Rough Inspection - Residential Failed 5/1/2020 5/1/2020 at 1:20 PM 05/01/2020
Misc
Corrective Action Required
05/01/2020
**RESTORE EROSION CONTROL ALONG THE STREET FRAMING: -Provide plan on site -Complete framing of I beam and column in garage -Complete roof ventilation above garage -Nail garage corner studs and siding to corner studs per code -Strap across broken top plate at garage/front entry wall intersection -Install front entry door frame per security code -Frame roof A-frame above front bedroom per plan. -Install hanger for ceiling double joist above west middle bedroom and kitchen range -Brace ends of roof support lvl beam against rotation -Check header size above rear of master bedroom -Install snow block at roof flashing of rear living room wall -Reanchor sill plate per code at rear sunroom (within middle 1/3 of sill plates) ; anchor within 12” of breaks -Check beam size under kitchen lvl beam point load -Insulate first, then solidblock all cantilevered joists -Install hanger in basement ELECTRICAL: -Install an outdoor receptacle within 25 to if AC unit -Protect laundry circuits; at top plate above master closet/laundry door; at master bedroom bottom plate; -Over filled box at master closet switch; at master bathroom switch -Complete wiring to rear outdoor receptacle; electrical in pantry; -Secure range circuit within 12” of box -Complete fireplace electrical PLUMBING: -Protect plumbing at foyer bathroom tub -Protect laundry washeR water line -Gas piping not complete MECHANICAL: -Complete install fireplace **DO NOT INSULATE
Gas Service Inspection - Residential Passed 5/8/2020 5/8/2020 05/08/2020
Misc
Resolved
05/08/2020
-Not ready
All Rough Inspection - Residential Failed 5/8/2020 5/8/2020 at 9:10 AM 05/08/2020
Misc
Corrective Action Required
05/01/2020
**CLEAN GRAVEL AND DIRT OFF THE STREET -Complete roof ventilation above garage -Check beam size under kitchen lvl beam point load **Install (4)2x4 support stud for the lvl beam; below in basement, install a steel column down to thicken slab **OK TO INSULATE
All Rough Inspection - Residential Failed 5/11/2020 5/11/2020 at 10:40 AM 05/11/2020
Misc
Corrective Action Required
05/08/2020
-Check beam size under kitchen lvl beam point load **Install (4)2x4 support stud for the lvl beam; below in basement, install a steel column down to thicken slab **OK TO INSULATE
All Rough Inspection - Residential Partial 5/12/2020 5/12/2020 at 9:55 AM 05/12/2020
Misc
Resolved
05/12/2020
-Install a steel column down to thicken slab **OK TO ROCK
Driveway Inspection Partial 6/3/2020 6/3/2020 06/03/2020
Misc
Informational
06/03/2020
Driveway- forms and materials passed pre-inspection.
Erosion Control Inspection Residential Failed 6/10/2020 06/10/2020
Misc
Corrective Action Required
06/10/2020
Please see blow . Over grown vegetation on lot. Per city ordinance: Section 302.4 shall be amended as follows: Weeds. Premises and exterior property shall be maintained free from weeds or plant growth in excess of 10". Noxious weeds shall be prohibited. Weeds shall be defined as all grasses, annual plants and vegetation, other than trees or shrubs provided; however, this term shall not include cultivated flowers and gardens. Upon failure of the owner or agent having charge of a property to cut and destroy weeds after service of a notice of violation, they shall be subject to prosecution in accordance with Section 106.3 and as prescribed by the authority having jurisdiction. Upon failure to comply with the notice of violation, any duly authorized employee of the jurisdiction or contractor hired by the jurisdiction shall be authorized to enter upon the property in violation and cut and destroy the weeds growing thereon, and the costs of such removal shall be paid by the owner or agent responsible for the property. (Ord. No. 8583, § 1, 3-19-2019)
Erosion Control Inspection Residential Failed 6/19/2020 at 2:40 PM 06/19/2020
Misc
Corrective Action Required
06/10/2020
Please see blow . Over grown vegetation on lot. Per city ordinance: Section 302.4 shall be amended as follows: Weeds. Premises and exterior property shall be maintained free from weeds or plant growth in excess of 10". Noxious weeds shall be prohibited. Weeds shall be defined as all grasses, annual plants and vegetation, other than trees or shrubs provided; however, this term shall not include cultivated flowers and gardens. Upon failure of the owner or agent having charge of a property to cut and destroy weeds after service of a notice of violation, they shall be subject to prosecution in accordance with Section 106.3 and as prescribed by the authority having jurisdiction. Upon failure to comply with the notice of violation, any duly authorized employee of the jurisdiction or contractor hired by the jurisdiction shall be authorized to enter upon the property in violation and cut and destroy the weeds growing thereon, and the costs of such removal shall be paid by the owner or agent responsible for the property. (Ord. No. 8583, § 1, 3-19-2019) **MOST OF THE WEED WERE MOWED DOWN; HOWEVER, ALONG THE FENCE WITHIN THIS LOT, THERE ARE STILL SOME OVERGROWN VEGETATION THAT NEEDS TO BE MOWED DOWN. I CONTACTED THE BUILDER (CODY) AND LET HIM KNOW
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/19/2020
DEFICIENT EROSION CONTROL INSTALLATION. INSTALL SILT FENCE ALONG THE STREET AND CLEAN MUD&GRAVEL OFF STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Passed 07/23/2020
Erosion Control Inspection Residential Passed 07/23/2020
Misc
Resolved
06/22/2020
Please see blow . Over grown vegetation on lot. Per city ordinance: Section 302.4 shall be amended as follows: Weeds. Premises and exterior property shall be maintained free from weeds or plant growth in excess of 10". Noxious weeds shall be prohibited. Weeds shall be defined as all grasses, annual plants and vegetation, other than trees or shrubs provided; however, this term shall not include cultivated flowers and gardens. Upon failure of the owner or agent having charge of a property to cut and destroy weeds after service of a notice of violation, they shall be subject to prosecution in accordance with Section 106.3 and as prescribed by the authority having jurisdiction. Upon failure to comply with the notice of violation, any duly authorized employee of the jurisdiction or contractor hired by the jurisdiction shall be authorized to enter upon the property in violation and cut and destroy the weeds growing thereon, and the costs of such removal shall be paid by the owner or agent responsible for the property. (Ord. No. 8583, § 1, 3-19-2019) **MOST OF THE WEED WERE MOWED DOWN; HOWEVER, ALONG THE FENCE WITHIN THIS LOT, THERE ARE STILL SOME OVERGROWN VEGETATION THAT NEEDS TO BE MOWED DOWN. I CONTACTED THE BUILDER (CODY) AND LET HIM KNOW
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/23/2020
DEFICIENT EROSION CONTROL INSTALLATION. INSTALL SILT FENCE ALONG THE STREET AND CLEAN MUD&GRAVEL OFF STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 7/23/2020 7/23/2020 at 8:10 AM 07/23/2020
Misc
Corrective Action Required
07/23/2020
-Obtain Lawn irrigation permit -Driveway not approved on record -Sod, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, etc -Garage door not self closing -Install switch and receptacle cover plates throughout -Install secondary lock device for slide door per LS security code -Complete kitchen plumbing and electrical -Securely fasten wiring per code along basement ceiling joists -Remove covers from smoke alarms -Seal return air space in basement -Complete electrical to water heater -Fasten cover to service panel -Provide AFCI protection for fireplace -Garage not inspected at this time. Painters still working in garage -Support receptacle yokes at garage receptacle and receptacle near AC
Driveway Inspection Passed 7/24/2020 7/24/2020 07/24/2020
Misc
Informational
06/03/2020
Driveway- forms and materials passed pre-inspection.
Misc
Informational
06/04/2020
Driveway passed final inspection.
Occupancy Inspection - Codes Residential Temporary C of O 7/27/2020 7/27/2020 at 9:05 AM 07/27/2020
Misc
Corrective Action Required
07/23/2020
-Obtain Lawn irrigation permit
Occupancy Inspection - Codes Residential Full C of O 07/27/2020
Misc
Resolved
07/27/2020
-Obtain Lawn irrigation permit
Documents & Images
Date Uploaded File Type Document Name
12/27/2019 Letter Codes Residential Plan Review
01/03/2020 Receipt Receipt for transaction: 2020-000037
01/03/2020 Letter DS Building Permit
01/06/2020 Plot Plan DOC010620-01062020080608
02/10/2020 Engineer Report/Study Garys Fndn 1113 NE Goshen Ct Lee's Summit Mo Footing Forming and Reinforcement Inspection Report 1-29-20
02/18/2020 Letter INSPECTION SUMMARY
02/19/2020 Letter INSPECTION SUMMARY
02/19/2020 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
05/11/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
06/03/2020 Letter INSPECTION SUMMARY
06/04/2020 Engineer Report/Study Final_2020.06.03_DPier_LSMO_Pat Cochran Concrete
06/10/2020 Letter INSPECTION SUMMARY
06/19/2020 Letter INSPECTION SUMMARY
07/23/2020 Letter INSPECTION SUMMARY
07/23/2020 Letter INSPECTION SUMMARY
07/23/2020 Letter INSPECTION SUMMARY
07/24/2020 Letter INSPECTION SUMMARY
07/27/2020 Letter Codes Temporary Certificate of Occupancy
07/27/2020 Letter Codes Final Certificate of Occupancy
07/27/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home