Summary
PRRES20193536
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT COVERED DECK
12/04/2019
12/11/2019
01/08/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
ZACHARY W MOFFETT, Address:2113 SPARROW CIRCLE   
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
PERMITTING@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/06/2019 12/10/2019
Steve Conrick
Residential Plan Review Approved 12/06/2019 12/05/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,291.69 $1,291.69 Paid 12/11/2019
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 12/11/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 12/11/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 12/11/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 12/11/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/11/2019
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/11/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/4/2020 2/4/2020 02/04/2020
Underslab Plumbing Inspection - Residential Passed 3/9/2020 3/9/2020 03/09/2020
Sewer Service Inspection - R Passed 3/30/2020 (11:15) 3/30/2020 03/30/2020
Water Service Inspection - R Passed 3/31/2020 3/31/2020 03/31/2020
Piers/Caissons Inspection - Residential Passed 5/13/2020 (11:00) 5/13/2020 at 11:29 AM 05/13/2020
Misc
Informational
05/13/2020
(1) 24 x 36 (2) 24 x 50 deck piers
Electrical Service Inspection Passed 6/23/2020 6/23/2020 06/23/2020
Gas Piping Inspection - Residential Passed 6/23/2020 6/23/2020 06/23/2020
Gas Service Inspection - Residential Passed 6/23/2020 6/23/2020 06/23/2020
All Rough Inspection - Residential Failed 6/23/2020 6/23/2020 06/23/2020
Misc
Corrective Action Required
06/23/2020
- Staple plans - Fireblock at HVAC, DWV fur outs in garage - Missing joist hanger, top of mud room at dbl joist connection - Nail off all joist hangers - Protect and secure pex at showers - Nail off all H2.5 truss straps, 1st floor bed - Seal all upward penetrations - Fireblock HVAC DWV chase living room - Protection plates at all NM within 1 1/4” of end of framing member - Truss hangers per plans - Truss bracing per plans - No truss layout found for 2nd floor - anchor all columns to floor - Joist hangers required at garage cantilever connection to dbl joist in basement, over 4’
All Rough Inspection - Residential Failed 6/29/2020 6/29/2020 06/29/2020
Misc
Corrective Action Required
06/29/2020
- Staple plans - Fireblock at HVAC, DWV fur outs in garage - Protect and support pex at showers - Fireblock HVAC DWV chase living room - Truss hangers per plans - Truss bracing per plans - No truss layout found for 2nd floor - unable to inspect 2nd floor - Complete and terminate NM master water closet
All Rough Inspection - Residential Failed 7/2/2020 7/2/2020 07/02/2020
Misc
Corrective Action Required
06/29/2020
- Truss hangers per plans - unable to determine 2nd floor - Truss bracing per plans - unable to determine 2nd floor - No truss package layout found in packet for 2nd floor - unable to inspect 2nd floor truss
All Rough Inspection - Residential Passed 7/7/2020 7/7/2020 07/07/2020
Misc
Resolved
07/07/2020
Sidewalk Inspection Partial 7/16/2020 7/16/2020 07/16/2020
Misc
Informational
07/16/2020
7-16-20 2:25pm They have the forms set to spec at this time and the aggregate is compacted. They have been told to use a broom Finnish and with white cure sprayed evenly.
Driveway Inspection Partial 7/16/2020 7/16/2020 07/16/2020
Misc
Informational
07/16/2020
7-16-20 2:28pm The forms are set and aggregate is compacted. They are ready to pour.
Sidewalk Inspection Passed 07/17/2020
Driveway Inspection Passed 07/17/2020
Occupancy Inspection - Codes Residential Failed 10/12/2020 10/12/2020 10/12/2020
Misc
Corrective Action Required
10/12/2020
-Complete final grade and sod -Install guardrail at front porch, more than 30” from grade -Place splash blocks at all downspout and sump pump discharge locations, minimum 36” discharge from foundation -Seal all penetrations in siding, seal along top of meter can and AC disconnect -Cleanup construction debris on lot -Anti tip device required in range -Security screws at back door -GFCI protection required at dishwasher -Label all dedicated outlets in garage and unfinished basement as not GFCI protected -Size attic access cover in garage to fit and seal
Plot Plan Inspection Failed 12/09/2020
Misc
Corrective Action Required
12/09/2020
Uncover manhole MH U-2 as shown on plot plan
Occupancy Inspection - Codes Residential Failed 12/9/2020 12/9/2020 12/09/2020
Misc
Corrective Action Required
12/09/2020
-Complete Sod -Place splash blocks at all downspout and sump pump discharge locations, minimum 36” discharge from foundation -Uncover manhole MH U-2 as shown on plot plan
Occupancy Inspection - Codes Residential Failed 12/10/2020 12/10/2020 12/10/2020
Misc
Corrective Action Required
12/09/2020
-Uncover manhole MH U-2 as shown on plot plan
Plot Plan Inspection Passed 1/8/2021 1/8/2021 01/08/2021
Occupancy Inspection - Codes Residential Full C of O 1/8/2021 1/8/2021 01/08/2021
Misc
Resolved
01/08/2021
Documents & Images
Date Uploaded File Type Document Name
12/05/2019 Letter Codes Residential Plan Review
12/11/2019 Receipt Receipt for transaction: 2019-007684
12/11/2019 Letter DS Building Permit
12/12/2019 Drawing DOC121219-12122019095422
12/12/2019 Plot Plan DOC121219-12122019095437
02/04/2020 Letter INSPECTION SUMMARY
03/09/2020 Letter INSPECTION SUMMARY
03/30/2020 Letter INSPECTION SUMMARY
03/31/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
07/02/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
07/17/2020 Letter INSPECTION SUMMARY
07/17/2020 Letter INSPECTION SUMMARY
10/12/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter INSPECTION SUMMARY
12/10/2020 Letter INSPECTION SUMMARY
01/08/2021 Plot Plan Approved Plot Plan
01/08/2021 Letter INSPECTION SUMMARY
01/08/2021 Letter Field Certificate of Occupancy
01/08/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: