Permit Application Status

PRRES20193386


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193386
Building Permit - Residential
Certificate of Occupancy
MCGRAW HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - PARTIAL FINISHED BASEMENT
11/18/2019
11/20/2019
11/02/2020
Locations
Contacts
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
chad@mcgraw-homes.com  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
UNITED ELECTRIC COMPANY, Address:PO BOX 723, Phone:(816) 795-2744  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/20/2019 11/20/2019
Dylan Eppert
Basement egress
Corrective Action Required
11/19/2019

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Basement elevation
Corrective Action Required
11/19/2019

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) PER MDP LOT IS BUILT FOR A DAYLIGHT NOT A WALKOUT.
As-graded plot plan
Corrective Action Required
11/19/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Drainage swales
Corrective Action Required
11/19/2019

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide NO DRAINAGE ARROW PROVIDED IN THE REAR OF LOT.
Residential Plan Review Approved 11/20/2019 11/19/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,232.66 $1,232.66 Paid 11/20/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid 11/20/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 11/20/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 11/20/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/20/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/20/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 11/22/2019 (10:30) 11/22/2019 at 10:35 AM 11/22/2019
Misc
Corrective Action Required
11/22/2019
THE PAD AT 3RD CAR GARAGE MUST BE DUG DOWN WITH BOTTOM FLATENED OUT
Underslab Plumbing Inspection - Residential Passed 12/30/2019 12/30/2019 at 8:45 AM 12/30/2019
Footing Inspection - Residential Passed 12/31/2019
Misc
Resolved
12/31/2019
THE PAD AT 3RD CAR GARAGE MUST BE DUG DOWN WITH BOTTOM FLATENED OUT
Sewer Service Inspection - R Passed 1/6/2020 (2:30) 1/6/2020 01/06/2020
Water Service Inspection - R Passed 1/7/2020 (10:45) 1/7/2020 01/07/2020
Piers/Caissons Inspection - Residential Passed 4/15/2020 (8:00) 4/15/2020 at 8:55 AM 04/15/2020
Electrical Service Inspection Failed 5/13/2020 5/13/2020 05/13/2020
Misc
Corrective Action Required
05/13/2020
-One neutral conductor in the service panel has damaged insulation
Gas Service Inspection - Residential Passed 5/13/2020 5/13/2020 05/13/2020
All Rough Inspection - Residential Failed 5/13/2020 5/13/2020 at 8:35 AM 05/13/2020
Misc
Corrective Action Required
05/13/2020
**REPAIR EROSION CONTROL ALONG THE PROPERTY LINE FRAMING: -Nail garage portal brace walls sheathing per code. Expose all nailing; nail all strap holes -Anchor sill plates within 12” of breaks -Provide full bearing support for front porch roof beam at garage wall -Complete framing around garage I beam -Brace ends of lvl beam against rotation -Nail together the ceiling beams above master bedroom; nail all other beams as well; Face-nail rafter-ceiling joist with 3-10d nails; check all nailings please -Nail hangers above master bathroom -Have engineer to address kitchen beam size. Currently double 16” lvl is installed -Anchor basement sill plates per code; anchor columns to floor -Toe nail all joists to top plates (3-10d or 4-8d) -Install security blocking for basement door at strike plate height -Install solid blocking under kitchen lvl beam point load ELECTRICAL: -Secure SE cable min 1.25” away from stud surface or provide protection -Install a smoke/CO alarm inside and outside front bedroom **DO NOT INSULATE
Electrical Service Inspection Passed 5/18/2020 5/18/2020 05/18/2020
Misc
Resolved
05/18/2020
-One neutral conductor in the service panel has damaged insulation
All Rough Inspection - Residential Failed 5/18/2020 5/18/2020 at 8:30 AM 05/18/2020
Misc
Corrective Action Required
05/13/2020
-Brace ends of lvl beam above the living rm against rotation -Nail hangers above master bathroom -Have engineer to address kitchen beam size. Currently double 16” lvl is installed -Toe nail all joists to top plates (3-10d or 4-8d) **DO NOT INSULATE
All Rough Inspection - Residential Passed 5/19/2020 5/19/2020 at 8:30 AM 05/19/2020
Misc
Resolved
05/19/2020
-Brace ends of lvl beam above the living rm against rotation -Nail hangers above master bathroom -Have engineer to address kitchen beam size. Currently double 16” lvl is installed -Toe nail all joists to top plates (3-10d or 4-8d) **DO NOT INSULATE
Driveway Inspection Partial 6/23/2020 6/23/2020 06/23/2020
Misc
Informational
06/23/2020
Driveway - forms and materials passed Pre-inspection. 6-23-20 Tuesday.
Driveway Inspection Passed 6/29/2020 6/29/2020 06/29/2020
Misc
Informational
06/23/2020
Driveway - forms and materials passed Pre-inspection. 6-23-20 Tuesday.
Misc
Informational
06/29/2020
Driveway - passed final inspection.
Sidewalk Inspection Partial 7/9/2020 (Ready Now) 7/9/2020 07/09/2020
Misc
Informational
07/09/2020
Sidewalk - forms and materials passed pre-inspection.
Sidewalk Inspection Passed 7/10/2020 7/10/2020 07/10/2020
Misc
Informational
07/09/2020
Sidewalk - forms and materials passed pre-inspection.
Misc
Informational
07/10/2020
Sidewalk - passed final inspection.
Occupancy Inspection - Codes Residential Failed 10/2/2020 10/2/2020 10/02/2020
Misc
Corrective Action Required
10/02/2020
-Obtain lawn irrigation permit -As-graded plot plan is required -Make sure that the sewer tracer wire and port are installed and available at grade level -Provide street address near source of light -Provide sump pump extension -Seal exterior wall penetrations -Install roof soffit screens -Garage door not self closing -Fix ground fault condition for half bathroom receptacle -Provide a wall receptacle at cabinet wall space on right side of fireplace -Provide gfci protection for master bathroom receptacles -Provide AFCI protection for washer outlet -Complete kitchen hood duct -Provide min 100 sq inch area for each combustion air opening -Anchor basement column -Securely support lawn irrigation to foundation wall
Plot Plan Inspection Passed 10/8/2020 10/08/2020
Occupancy Inspection - Codes Residential Full C of O 11/2/2020 11/2/2020 11/02/2020
Misc
Resolved
11/02/2020
-Make sure that the sewer tracer wire and port are installed and available at grade level -Provide street address near source of light -Provide sump pump extension -Seal exterior wall penetrations -Install roof soffit screens -Garage door not self closing -Fix ground fault condition for half bathroom receptacle -Provide a wall receptacle at cabinet wall space on right side of fireplace -Provide gfci protection for master bathroom receptacles -Provide AFCI protection for washer outlet -Complete kitchen hood duct -Provide min 100 sq inch area for each combustion air opening -Anchor basement column -Securely support lawn irrigation to foundation wall
Documents & Images
Date Uploaded File Type Document Name
11/19/2019 Letter Codes Residential Plan Review
11/20/2019 Receipt Receipt for transaction: 2019-007409
11/20/2019 Letter DS Building Permit
11/21/2019 Engineer Report/Study DOC112119-006
11/21/2019 Plot Plan DOC112119-007
11/22/2019 Letter INSPECTION SUMMARY
12/30/2019 Letter INSPECTION SUMMARY
12/31/2019 Letter INSPECTION SUMMARY
01/06/2020 Letter INSPECTION SUMMARY
01/07/2020 Letter INSPECTION SUMMARY
04/15/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/18/2020 Letter INSPECTION SUMMARY
05/18/2020 Letter INSPECTION SUMMARY
05/19/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
07/09/2020 Letter INSPECTION SUMMARY
07/10/2020 Letter INSPECTION SUMMARY
10/02/2020 Letter INSPECTION SUMMARY
10/07/2020 Plot Plan APPROVED AS-BUILT
11/02/2020 Letter Codes Final Certificate of Occupancy
11/02/2020 Letter Field Certificate of Occupancy
11/02/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home