Summary
PRRES20193374
Building Permit - Residential
Certificate of Occupancy
Wood Brothers Construction INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT COVERED DECK
11/15/2019
12/05/2019
08/18/2022
Locations
Contacts
Wood Brothers Construction INC, Address:PO Box 553  
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
DAVE'S ELECTRIC, Address:1601 SW JEFFERSON ST, Phone:(816) 525-0409  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
WOODBROTHERSINC@GMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/22/2019 11/22/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
11/21/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 11/21/2019 11/21/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,725.30 $1,725.30 Paid 12/05/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/05/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/05/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 12/05/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 12/05/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 12/05/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/23/2019 12/23/2019 at 1:25 PM 12/23/2019
Underslab Plumbing Inspection - Residential Passed 2/24/2020 2/24/2020 at 8:45 AM 02/24/2020
Piers/Caissons Inspection - Residential Passed 3/26/2020 at 1:10 PM 03/26/2020
Sewer Service Inspection - R Passed 4/30/2020 4/30/2020 at 12:55 PM 04/30/2020
Water Service Inspection - R Passed 5/1/2020 (10:15) 5/1/2020 at 11:00 AM 05/01/2020
All Rough Inspection - Residential Failed 8/7/2020 8/7/2020 08/06/2020
Misc
Corrective Action Required
08/06/2020
**FRAMING: -Deck: shim gap under deck beam at post support; shim gap at joist hanger support -Support hips above master bedroom -Provide hanger support at lvl-lvl connection above rear bedroom -Anchor basement sill plates within 12” of breaks -Misplaced I beam support column at basement wet bar area ELECTRICAL: -Protect wiring within six ft of attic access above master bedroom MECHANICAL: -Tape seal hole in bath fan duct above master toilet PLUMBING: -Protect water lines at oven; condensate drain pipe at mud wall **OK TO INSULATE
Electrical Service Inspection Passed 8/7/2020 8/7/2020 08/06/2020
Gas Service Inspection - Residential Failed 8/7/2020 8/7/2020 08/06/2020
Misc
Corrective Action Required
08/06/2020
Pressure less than ten psi
All Rough Inspection - Residential Passed 8/18/2020 8/18/2020 at 8:55 AM 08/18/2020
Misc
Resolved
08/18/2020
**FRAMING: -Deck: shim gap under deck beam at post support; shim gap at joist hanger support -Support hips above master bedroom -Provide hanger support at lvl-lvl connection above rear bedroom -Anchor basement sill plates within 12” of breaks -Misplaced I beam support column at basement wet bar area ELECTRICAL: -Protect wiring within six ft of attic access above master bedroom MECHANICAL: -Tape seal hole in bath fan duct above master toilet PLUMBING: -Protect water lines at oven; condensate drain pipe at mud wall **OK TO INSULATE
Gas Service Inspection - Residential Failed 8/18/2020 08/18/2020
Misc
Corrective Action Required
08/06/2020
Pressure less than ten psi **Cannot get to the gauge because of the sheetrock in the way
Driveway Inspection Passed 09/08/2020
Misc
Informational
09/08/2020
Driveway - passed pre-inspection on 9/320. Final inspection 9/8/20 8:20AM Driveway passed.
Gas Service Inspection - Residential Passed 11/17/2020 11/17/2020 11/17/2020
Misc
Resolved
11/17/2020
Pressure less than ten psi **Cannot get to the gauge because of the sheetrock in the way
Occupancy Inspection - Codes Residential Failed 4/13/2021 4/13/2021 04/13/2021
Misc
Corrective Action Required
04/13/2021
-As-graded plot plan is required -Clear out obstruction at the rear storm inlet and install silt fence around -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, above all exterior gfci receptacles, above AC disconnects -Paint the gas service piping -Provide min 6” clearance from siding to grade at north side -Secure north side exterior gfci receptacle and seal above all exterior gfci receptacles -Provide landing outside escape well window and install ladder -Install tamper-proof caps at AC valves -City amendment of the NEC requires all dedicated non-gfci receptacles in garage and unfinished basement to be identified (label, marking, etc) -Where’s the breaker for the oven? Install breaker lock for oven -Remove all foundation wall ties -Install breaker lock for out-of-sight water heater -Protect wiring running across bottom of floor joists; secure wiring every 4.5 ft of less -Furnace condensate lines must be able to be cleaned out -Add more support for the AC lines and exhaust pvc per installation manual
Occupancy Inspection - Codes Residential Temporary C of O 4/14/2021 4/14/2021 04/14/2021
Misc
Corrective Action Required
04/13/2021
-As-graded plot plan is required -Clear out obstruction at the rear storm inlet and install silt fence around -Provide min 6” clearance from siding to grade at north side -Provide landing outside escape well window and install ladder -Add more support for the AC lines and exhaust pvc per installation manual **leave the manual on site for the AC. Support furnace 2” pvc at max 5 ft interval
Occupancy Inspection - Codes Residential Full C of O 08/18/2022
Misc
Resolved
08/18/2022
-As-graded plot plan is required -Clear out obstruction at the rear storm inlet and install silt fence around -Provide min 6” clearance from siding to grade at north side -Provide landing outside escape well window and install ladder
Documents & Images
Date Uploaded File Type Document Name
11/21/2019 Letter Codes Residential Plan Review
12/05/2019 Receipt Receipt for transaction: 2019-007599
12/05/2019 Letter DS Building Permit
12/05/2019 Plot Plan DOC120519-015
12/23/2019 Letter INSPECTION SUMMARY
02/24/2020 Letter INSPECTION SUMMARY
03/26/2020 Letter INSPECTION SUMMARY
04/30/2020 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
08/06/2020 Letter INSPECTION SUMMARY
08/06/2020 Letter INSPECTION SUMMARY
08/06/2020 Letter INSPECTION SUMMARY
08/18/2020 Letter INSPECTION SUMMARY
08/18/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
04/13/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter Codes Temporary Certificate of Occupancy
08/18/2022 Letter Codes Final Certificate of Occupancy
08/18/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home