Permit Application Status

PRRES20193373


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193373
Building Permit - Residential
Certificate of Occupancy
Wood Brothers Construction INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - PATIAL FINISHED BASEMENT
11/15/2019
02/13/2020
02/27/2024
Locations
Contacts
Wood Brothers Construction INC, Address:PO Box 553  
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
WOODBROTHERSINC@GMAIL.COM  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
DREWIS ELECTRIC INC, Address:1714 N 4TH AVE E, Phone:(515) 208-7779  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/20/2019 12/05/2019
Dylan Eppert
Basement egress
Corrective Action Required
11/18/2019

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. BASEMENT EGRESS WELL NOT LABELED FOR BEDROOM #3
Miscellaneous Correction
Corrective Action Required
11/19/2019

DECK ON PLOT PLAN IS LABELED DECK HOWEVER CONSTRUCTION DRAWINGS SHOW COVERED DECK AND UNCOVERED DECK PLEASE CLARIFY.
Planning Review (RES) Approved 11/20/2019 11/18/2019
Dylan Eppert
Residential Plan Review Approved 11/20/2019 11/18/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,121.91 $1,121.91 Paid 02/13/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 02/13/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 02/13/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 02/13/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/13/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/13/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 5/1/2020 (9:30) 5/1/2020 at 8:55 AM 05/01/2020
Misc
Corrective Action Required
05/01/2020
MISSING A PIER PAD NEAR STAIR FOOTING
Footing Inspection - Residential Passed 05/01/2020
Misc
Resolved
05/01/2020
MISSING A PIER PAD NEAR STAIR FOOTING
Underslab Plumbing Inspection - Residential Passed 6/2/2020 6/2/2020 at 8:50 AM 06/02/2020
Sewer Service Inspection - R Passed 6/18/2020 (1:45) 6/18/2020 at 2:10 PM 06/18/2020
Water Service Inspection - R Passed 6/23/2020 (9:15) 6/23/2020 at 9:35 AM 06/23/2020
Piers/Caissons Inspection - Residential Passed 6/24/2020 06/24/2020
Informational
06/24/2020
REMOVE THE LUMBER OUT OF THE HOLE BEFORE POURING
Driveway Inspection Partial 3/3/2021 3/3/2021 03/03/2021
Misc
Informational
03/03/2021
Driveway - forms and materials passed pre-inspection. contractor needs to ensure they patch broken curb.
Driveway Inspection Passed 3/5/2021 3/5/2021 03/05/2021
Misc
Informational
03/03/2021
Driveway - forms and materials passed pre-inspection. contractor needs to ensure they patch broken curb.
Misc
Informational
03/05/2021
Driveway - passed final inspection.
Electrical Service Inspection Passed 3/11/2021 3/11/2021 03/11/2021
Gas Service Inspection - Residential Passed 3/11/2021 3/11/2021 03/11/2021
All Rough Inspection - Residential Failed 3/11/2021 3/11/2021 03/11/2021
Misc
Corrective Action Required
03/11/2021
FRAMING: -Install garage portal wall straps -Strap wall top plates lapped less than 24” in master bathroom closet -Install security blocking at deck door -Brace ends of lvl beam from rotation -Reinforce non-continuous studs at front bedroom gable wall (strapping across hinge line) -Add another stud for support of stoop beam at front bedroom wall -Fb basement wall vertically every ten ft or less ; fb wall from I beam soffit ; fb space at basement bathroom shower from joist space; fb rear basement bedroom wall from joist space -Install 2 stud support for lvl beam at stair wall -Anchor basement column -Support point load under front bedroom lvl ridge to I beam in basement ELECTRICAL: -Complete electrical in garage; outdoor receptacle outside garage; complete electrical throughout -Protect SE at master closet; at deck door; at oven; PLUMBING: -Protect water line at master shower MECHANICAL: -Pan off basement family room return air space from fir down ceiling space **OK TO INSULATE
All Rough Inspection - Residential Failed 3/18/2021 3/18/2021 03/18/2021
Misc
Corrective Action Required
03/11/2021
FRAMING: -Fb wall from I beam soffit ; fb space at basement bathroom shower from joist space ELECTRICAL: -Complete electrical throughout **Secure wiring within 12" of panel **OK TO INSULATE
All Rough Inspection - Residential Passed 9/3/2021 9/3/2021 09/03/2021
Misc
Resolved
09/03/2021
FRAMING: -Fb wall from I beam soffit ; fb space at basement bathroom shower from joist space ELECTRICAL: -Complete electrical throughout **Secure wiring within 12" of panel **OK TO INSULATE
Occupancy Inspection - Codes Residential Failed 9/3/2021 9/3/2021 09/03/2021
Misc
Corrective Action Required
09/03/2021
-Obtain lawn irrigation permit and submit the backflow test report to city -Sidewalk not installed -Final grade, sod, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, etc -Front entry light fixtures must be such that the light bulbs cannot be removed without tooling -Exterior not inpected. Complete all exterior -Complete deck -Deck receptacle cover plate not installed -Complete circuit to cooktop j-box. Use proper raceway -Install cooktop, oven, and kitchen hood -Install stair handrail -Receptacle located within six ft of wet bar sink must be gfci-protected -Smoke alarm at front basement bedroom not interconnected -Provide handle tie for multi wire branch circuit -Label all breakers -Install breaker lock for oven, cooktop, and hood -Install face plate for furnace switch -Secure NM cables every 4.5 ft or less -Seal water service line penetration of foundation wall -Secure lawn irrigation water line
Occupancy Inspection - Codes Residential Temporary C of O 9/3/2021 09/03/2021
Misc
Corrective Action Required
09/03/2021
-Obtain lawn irrigation permit and submit the backflow test report to city -Sidewalk not installed -Final grade, sod, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, etc -Front entry light fixtures must be such that the light bulbs cannot be removed without tooling -Exterior not inpected. Complete all exterior -Complete deck -Deck receptacle cover plate not installed -Complete circuit to cooktop j-box. Use proper raceway -Install cooktop, oven, and kitchen hood -Install stair handrail -Receptacle located within six ft of wet bar sink must be gfci-protected -Smoke alarm at front basement bedroom not interconnected -Provide handle tie for multi wire branch circuit -Label all breakers -Install breaker lock for oven, cooktop, and hood -Install face plate for furnace switch -Secure NM cables every 4.5 ft or less -Seal water service line penetration of foundation wall -Secure lawn irrigation water line
Occupancy Inspection - Codes Residential Temporary C of O 9/8/2021 9/8/2021 09/08/2021
Misc
Corrective Action Required
09/03/2021
-Final grade, sod, downspout and sump pump extensions -Exterior: paint gas service piping; install tamper proof caps at AC shraeder valves; ladder at window well
Documents & Images
Date Uploaded File Type Document Name
11/19/2019 Letter Codes Residential Plan Review
02/13/2020 Receipt Receipt for transaction: 2020-000583
02/13/2020 Letter DS Building Permit
05/01/2020 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
06/02/2020 Letter INSPECTION SUMMARY
06/18/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
03/03/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/18/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter Codes Temporary Certificate of Occupancy
09/03/2021 Plot Plan APPROVED PLOT PLAN
09/07/2021 Lawn irrigation permit
09/08/2021 Letter Codes Temporary Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home