Permit Application Status

PRRES20192818


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20192818
Building Permit - Residential
Certificate of Occupancy
FOUSHEE HOMES INC
NEW SINGLE FAMILY
NEW HOUSE WITH FINISHED AND UNFINISHED BASEMENT AND DECK
09/30/2019
10/03/2019
11/12/2020
Locations
Contacts
FOUSHEE HOMES INC, Address:4064 NE CHAPEL MANOR DR  
FOUSHEE HOMES INC, Address:2511 RINGO ROAD, Phone:(816) 918-2958  
BF.FOUSHEE@GMAIIL.COM  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 10/02/2019 10/02/2019
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
10/01/2019

Braced wall detail references 2012 building code and must reference 2018.
Miscellaneous Correction
Corrective Action Required
10/01/2019

The notes page reference an optional suspended stoop is this going to be a suspended slab or not?
Plot Plan Review Approved 10/02/2019 10/01/2019
Dylan Eppert
Legal description
Corrective Action Required
10/01/2019

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. PLAT NUMBER WAS NOT LISTED.
Property boundary
Corrective Action Required
10/01/2019

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. BEARING ON EAST SIDE IS MISSING.
Basement egress
Corrective Action Required
10/01/2019

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. EGRESS WELL IS MISSING ON THE NORTH SIDE WHERE BEDROOM #3 IS LOCATED IN THE BASEMENT.
Planning Review (RES) Rejected 10/03/2019 10/01/2019
Victoria Nelson
Miscellaneous Correction
Corrective Action Required
10/01/2019

Please label materials for exterior elevations
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,019.20 $1,019.20 Paid 10/03/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid 10/03/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 10/03/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 10/03/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/03/2019
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/03/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/8/2019 10/8/2019 at 1:15 PM 10/08/2019
Underslab Plumbing Inspection - Residential Failed 10/23/2019 at 10:00 AM 10/23/2019
Misc
Corrective Action Required
10/23/2019
-NOT READY
Sewer Service Inspection - R Passed 11/4/2019 11/4/2019 at 10:35 AM 11/04/2019
Water Service Inspection - R Partial 11/4/2019 11/04/2019
Water Service Inspection - R Passed 11/5/2019 (11:15) 11/5/2019 at 1:15 PM 11/05/2019
Underslab Plumbing Inspection - Residential Passed 11/20/2019 11/20/2019 11/20/2019
Misc
Resolved
11/20/2019
-NOT READY
Foundation Inspection - Residential Partial 12/23/2019 12/23/2019 at 1:00 PM 12/23/2019
Misc
Corrective Action Required
12/23/2019
-Based on the conversation with the foreman there, the basement was filled with AB3. Slab reinforcement was #4@24" on center. -Garage floor rebars not epoxied into the foundation wall. No plan on site
All Rough Inspection - Residential Failed 5/5/2020 5/5/2020 at 9:00 AM 05/05/2020
Misc
Corrective Action Required
05/05/2020
GARAGE PORTAL WALLS FRAMING ONLY-OK
All Rough Inspection - Residential Failed 5/15/2020 5/15/2020 at 9:25 AM 05/15/2020
Misc
Corrective Action Required
05/05/2020
-GARAGE PORTAL WALLS FRAMING ONLY-OK **GO AHEAD AND INSULATE THE CANTILEVERED JOISTS. I WILL INSPECT THE SOLIDBLOCKING AT ALL-ROUGH
Gas Service Inspection - Residential Passed 6/10/2020 6/10/2020 06/10/2020
Electrical Service Inspection Failed 6/10/2020 6/10/2020 06/10/2020
Misc
Corrective Action Required
06/10/2020
-Protect SE conductor connections to service panel power bus bars
All Rough Inspection - Residential Failed 6/10/2020 6/10/2020 at 8:50 AM 06/10/2020
Misc
Corrective Action Required
05/15/2020
FRAMING: -Exterior wall on the north side is less than ten ft from the house to the north and is required to have 1-hr fire rating with exposure on both sides -Anchor sill plate within 12” of breaks -Nail corner studs per code -Fb double stud wall at garage/stair from roof; Fb all floor penetrations -Tempered glass window required where within 2 ft of master bedroom exterior door -Install security blocking for exterior doors -Provide full support for living room ceiling beam -Block underneath point load -Anchor basement columns to floor; tighten down all basement anchor nuts; anchor within 12” of breaks -Toe nail joists to basement sill and top wall plates per code -Fb space at basement bathroom shower from ceiling space -Provide full support for double joists in basement -Solidblock cantilevered joist at north basement wall -Move roof load at front bedroom and bathroom to other bearing walls or install double joists below MECHANICAL: -Pan off return air space from rest of stud space not used as return air -At basement bedroom and bathroom, pan off return air space from ceiling fur down and unused joist space; seal return air space from other joist space; install wall register -Lower supply duct to bedroom ceiling level ELECTRICAL: -Protect wiring within six ft of attic access; secure wiring to attic light along framing -Secure wiring per code at dining door to deck -Protect wiring running across bottom of joists in basement -Secure wiring min 1” from water heater b-vent -Parallel electrical wiring inside return air space along the stair -Secure and support wiring above basement family area at interval no more than 4.5 ft -Unbend kitchen range cable below range **DO NOT INSULATE
Misc
Corrective Action Required
06/12/2020
scheduling for 6/15 pending -rated north wall rating all other items will be complete.Robert 816-918-2958
All Rough Inspection - Residential Failed 6/15/2020 6/15/2020 06/15/2020
Misc
Corrective Action Required
06/10/2020
FRAMING: -Exterior wall on the north side is less than ten ft from the house to the north and is required to have 1-hr fire rating with exposure on both sides - -Nail corner studs per code -Fb double stud wall at garage/stair from roof; Fb all floor penetrations ( seal top) -Tempered glass window required where within 2 ft of master bedroom exterior -; anchor within 12” of breaks ( anchor bolt bottom plate at steel column patio door) -Fb space at basement bathroom shower from ceiling space( seal top) ELECTRICAL -Parallel electrical wiring inside return air space along the stair -Overbend kitchen range cable below range **DO NOT INSULATE
Electrical Service Inspection Failed 6/15/2020 6/15/2020 06/15/2020
Misc
Corrective Action Required
06/10/2020
-Protect SE conductor connections to service panel power bus bars
All Rough Inspection - Residential Failed 7/2/2020 7/2/2020 at 9:20 AM 07/02/2020
Misc
Corrective Action Required
06/15/2020
-Exterior wall on the north side is less than ten ft from the house to the north and is required to have 1-hr fire rating with exposure on both sides **Inspect later as approved by CMR -Tempered glass window required where within 2 ft of master bedroom exterior **Check later -Fb wall space at basement wet bar from ceiling space (fb top) **Use fiberglass to fb the holes. Take pictures **OK TO INSULATE/ROCK IF THE FIREBLOCKING IS DONE
Electrical Service Inspection Failed 7/2/2020 7/2/2020 07/02/2020
Misc
Corrective Action Required
06/15/2020
-Protect SE conductor connections to service panel power bus bars **The panel should come with the protective caps
All Rough Inspection - Residential Failed 7/29/2020 7/29/2020 at 9:20 AM 07/29/2020
Misc
Corrective Action Required
07/02/2020
-Exterior wall on the north side is less than ten ft from the house to the north and is required to have 1-hr fire rating with exposure on both sides **Code requires 1 hr rating with exposure on both sides for fire sepration distance less than 10 ft. This means 5/8" type X rock on the interior side as well for the wall with <10ft fire separation distance. Please get back to the city for CMR approval -Tempered glass window required where within 2 ft of master bedroom exterior **Check later
Electrical Service Inspection Passed 7/30/2020 7/30/2020 at 7:50 AM 07/30/2020
Misc
Resolved
07/30/2020
-Protect SE conductor connections to service panel power bus bars **The panel should come with the protective caps
Driveway Inspection Partial 8/13/2020 (P.M.) 8/13/2020 08/13/2020
Misc
Informational
08/13/2020
8-13-20 2:02pm The forms are set and the aggregate is compacted. They are ready to pour.
Erosion Control Inspection Residential Passed 11/10/2020 11/10/2020 11/10/2020
Piers/Caissons Inspection - Residential Passed 11/10/2020
Occupancy Inspection - Codes Residential Failed 11/10/2020 11/10/2020 11/10/2020
Miscellaneous Correction
Informational
10/08/2019
-Obtain lawn sprinkler permit and backflow certification -Install cooktop Deck: -Provide missing bolts 16" OC in end joists at house -Provide angle clips on end joists not fully bearing on post -Provide (2) bolts in each rim joist to post connection -Provide graspable handrail at steps
Foundation Inspection - Residential Passed 11/12/2020
Misc
Informational
11/12/2020
-Based on the conversation with the foreman there, the basement was filled with AB3. Slab reinforcement was #4@24" on center. -Garage floor rebars not epoxied into the foundation wall. No plan on site
Occupancy Inspection - Codes Residential Full C of O 11/12/2020 11/12/2020 11/12/2020
Miscellaneous Correction
Resolved
11/12/2020
-Obtain lawn sprinkler permit and backflow certification -Install cooktop Deck: -Provide missing bolts 16" OC in end joists at house -Provide angle clips on end joists not fully bearing on post -Provide (2) bolts in each rim joist to post connection -Provide graspable handrail at steps
Documents & Images
Date Uploaded File Type Document Name
10/01/2019 Letter Codes Residential Plan Review
10/03/2019 Receipt Receipt for transaction: 2019-006595
10/03/2019 Letter DS Building Permit
10/03/2019 Plot Plan DOC100319-007
10/08/2019 Letter INSPECTION SUMMARY
10/23/2019 Letter INSPECTION SUMMARY
11/04/2019 Letter INSPECTION SUMMARY
11/04/2019 Letter INSPECTION SUMMARY
11/05/2019 Letter INSPECTION SUMMARY
11/20/2019 Letter INSPECTION SUMMARY
11/20/2019 Letter INSPECTION SUMMARY
11/20/2019 Letter INSPECTION SUMMARY
12/23/2019 Letter INSPECTION SUMMARY
05/05/2020 Letter INSPECTION SUMMARY
05/15/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/22/2020 Plot Plan scan_98498_2020-06-22-14-39-32
07/02/2020 Letter INSPECTION SUMMARY
07/02/2020 Letter INSPECTION SUMMARY
07/29/2020 Letter INSPECTION SUMMARY
07/30/2020 Letter INSPECTION SUMMARY
08/13/2020 Letter INSPECTION SUMMARY
10/15/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/12/2020 Letter Codes Final Certificate of Occupancy
11/12/2020 Letter Field Certificate of Occupancy
11/12/2020 Letter INSPECTION SUMMARY
11/12/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents