Permit Application Status

PRRES20191430


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191430
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - ROOF TRUSS - SUSPENDED SLAB - UNFINISHED BASEMENT
06/05/2019
06/10/2019
04/15/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/07/2019 06/10/2019
Dylan Eppert
City infrustructure
Corrective Action Required
06/05/2019

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. *missing sanitary manholes. Confused on the storm mh in the rear yard.
Residential Plan Review Approved 06/07/2019 06/05/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,463.46 $1,463.46 Paid 06/10/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/10/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 06/10/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 06/10/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/10/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/10/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/10/2019 (8:30) 7/10/2019 at 8:30 AM 07/10/2019
Concrete Walls and Columns Inspection Passed 7/19/2019 7/19/2019 07/19/2019
Sewer Service Inspection - R Passed 7/26/2019 7/26/2019 at 3:00 PM 07/26/2019
Water Service Inspection - R Partial 7/26/2019 07/26/2019
Water Service Inspection - R Passed 7/29/2019 7/29/2019 at 1:00 PM 07/29/2019
Underslab Plumbing Inspection - Residential Passed 8/2/2019 8/2/2019 at 8:45 AM 08/02/2019
Electrical Service Inspection Passed 10/11/2019 10/11/2019 10/11/2019
Gas Service Inspection - Residential Failed 10/11/2019 10/11/2019 10/11/2019
Miscellaneous Correction
Corrective Action Required
10/11/2019
No pressure on system
Gas Piping Inspection - Residential Passed 10/11/2019 10/11/2019 10/11/2019
All Rough Inspection - Residential Failed 10/11/2019 10/11/2019 10/11/2019
Misc
Corrective Action Required
10/11/2019
** Draft stop has not been done throughout the house ** Main floor bathroom does not have an exhaust vent ** Flex room has wall space over 24” under window without an outlet ** North west upstairs bedroom is missing wire protection in the corner ** Windows at master bath tub need to be safety glass ** Missing joist hanger under porch
Gas Service Inspection - Residential Passed 10/15/2019 10/15/2019 10/15/2019
Miscellaneous Correction
Resolved
10/15/2019
No pressure on system
All Rough Inspection - Residential Passed 10/15/2019 10/15/2019 10/30/2019
Misc
Resolved
10/30/2019
Misc
Resolved
10/30/2019
Driveway Inspection Partial 11/20/2019 11/20/2019 11/20/2019
Misc
Informational
11/20/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 11/20/2019 (P.M.) 11/20/2019 11/20/2019
Misc
Informational
11/20/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 11/27/2019 12/09/2019
Misc
Informational
11/20/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 11/27/2019 12/09/2019
Misc
Informational
11/20/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 1/29/2020 01/29/2020
Misc
Corrective Action Required
01/29/2020
-Seal outside light fixtures -guard rail needed on front porch where over 30” from grade -security screws needed at rear door -Anti siphon device set screw needs to be sheared off -Final grade, sod, and splash blocks need to be installed -Microwave and oven need to have lockout device in electrical panel -Sump pump discharge need to be 36 inches from foundation -Proper Joist hangers needed for deck stair landing on north side -Hard surface landing needed for exterior deck -Secure AC whip
All Rough Inspection - Residential Passed 1/29/2020 01/30/2020
Misc
Resolved
01/30/2020
Misc
Resolved
01/30/2020
** Main floor bathroom does not have an exhaust vent ** Flex room has wall space over 24” under window without an outlet
Occupancy Inspection - Codes Residential Temporary C of O 1/30/2020 1/30/2020 01/30/2020
Misc
Corrective Action Required
01/29/2020
-Seal outside light fixtures -guard rail needed on front porch where over 30” from grade -Final grade, sod, and splash blocks need to be installed -Sump pump discharge need to be 36 inches from foundation -Proper Joist hangers needed for deck stair landing on north side -Secure AC whip
Occupancy Inspection - Codes Residential Full C of O 4/15/2020 4/15/2020 04/15/2020
Misc
Resolved
04/15/2020
Documents & Images
Date Uploaded File Type Document Name
06/05/2019 Letter Codes Residential Plan Review
06/10/2019 Receipt Receipt for transaction: 2019-003438
06/10/2019 Letter Codes Building Permit
06/12/2019 Plot Plan DOC061219-06122019083034
07/10/2019 Letter INSPECTION SUMMARY
07/19/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
08/02/2019 Letter INSPECTION SUMMARY
08/08/2019 Engineer Report/Study 4425 Nautilus Pl_Lot 18 Raintree Lake Final_2019.08.05_BSlab_LSMO_Pat Cochran
08/15/2019 Engineer Report/Study 4425 SW Nautilus Pl_Lot 18 Raintree Lake Final_2019.08.14_SuspGSlab_LSMO_Pat Cochran
10/11/2019 Letter INSPECTION SUMMARY
10/11/2019 Letter INSPECTION SUMMARY
10/11/2019 Letter INSPECTION SUMMARY
10/11/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/30/2019 Letter INSPECTION SUMMARY
11/20/2019 Letter INSPECTION SUMMARY
11/20/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
01/29/2020 Letter INSPECTION SUMMARY
01/30/2020 Letter Codes Temporary Certificate of Occupancy
04/15/2020 Letter Field Certificate of Occupancy
04/15/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home