Permit Application Status

PRRES20190134


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20190134
Building Permit - Residential
Certificate of Occupancy
WYSS HOME BUILDING LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
01/23/2019
04/03/2019
12/11/2020
Locations
Contacts
WYSS HOME BUILDING LLC, Address:PO BOX 6620, Phone:(816) 820-0142  
WYSS HOME BUILDING LLC, Address:PO BOX 6620, Phone:(816) 820-0142  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
ROBERTSON PLUMBING LLC, Address:PO BOX 165, Phone:(816) 781-9340  
MCRWYSS@HOTMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/31/2019 01/31/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
01/25/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Add note "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING"***
Drainage swales
Corrective Action Required
01/25/2019

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provideD ***This lot is at the tail end of the swale running west to east. Make note of swale. The contours in the rear yard should give an understanding of how the swale needs to be maintained.***
Residential Plan Review Approved 01/25/2019 01/25/2019
Kim Brennan
Misc
Corrective Action Required
01/23/2019

Please provide the address to the property on all pages of the drawings.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,153.22 $1,153.22 Paid 04/03/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/03/2019
8331507-Sewer Connection Fee $480.00 $480.00 Paid 04/03/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 04/03/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 04/03/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 4/8/2019 4/8/2019 at 9:30 AM 04/08/2019
Water Service Inspection - R Passed 4/8/2019 4/8/2019 at 1:40 PM 04/08/2019
Erosion Control Inspection Residential Failed 4/11/2019 04/11/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/11/2019
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 4/11/2019 4/11/2019 at 9:30 AM 04/11/2019
Electrical Service Inspection Passed 7/3/2019 07/03/2019
Gas Service Inspection - Residential Passed 7/3/2019 07/03/2019
All Rough Inspection - Residential Failed 7/3/2019 7/3/2019 at 8:50 AM 07/03/2019
Misc
Corrective Action Required
07/03/2019
FRAMING: -Nail siding to sill plate outside master closet -Install (3)2x4 stud support for lvl beam at pantry/dead space wall -Fb fireplace space from roof; Fb all basement wall from ceiling space; Insulation must fill the whole depth of wall space and min 16” below ceiling level; Insulation used as fireblocking material must have paper face removed; fireblocking insulation must be securely stapled in place; Fb all dead spaces from ceiling space; -Nail stud in rear basement bedroom/bathroom wall -Support upper stair step ELECTRICAL: -Protect wiring at garage wall near 3rd car wall receptacle PLUMBING: -Protect 3” plumbing at ceiling in basement bathroom -Support all plumbing at max 4 ft spacing -Protect plumbing in rear basement bathroom closet -Provide access to clean out behind the basement arty thing **OK TO INSULATE
All Rough Inspection - Residential Passed 7/11/2019 7/11/2019 at 11:05 AM 07/11/2019
Misc
Resolved
07/11/2019
FRAMING: -Nail siding to sill plate outside master closet -Install (3)2x4 stud support for lvl beam at pantry/dead space wall -Fb fireplace space from roof; Fb all basement wall from ceiling space; Insulation must fill the whole depth of wall space and min 16” below ceiling level; Insulation used as fireblocking material must have paper face removed; fireblocking insulation must be securely stapled in place; Fb all dead spaces from ceiling space; -Nail stud in rear basement bedroom/bathroom wall -Support upper stair step ELECTRICAL: -Protect wiring at garage wall near 3rd car wall receptacle PLUMBING: -Protect 3” plumbing at ceiling in basement bathroom -Support all plumbing at max 4 ft spacing -Protect plumbing in rear basement bathroom closet -Provide access to clean out behind the basement arty thing **OK TO INSULATE
Driveway Inspection Passed 7/19/2019 (A.M.) 7/19/2019 07/22/2019
Misc
Informational
07/19/2019
Driveway - forms and materials passed pre-inspection .
Misc
Informational
07/22/2019
Driveway - passed final inspection .
Driveway Inspection Passed 10/15/2019 10/15/2019 10/15/2019
Misc
Informational
07/19/2019
Driveway - forms and materials passed pre-inspection .
Misc
Informational
10/15/2019
Driveway - passed final inspection.
Erosion Control Inspection Residential Passed 10/17/2019
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/17/2019
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 10/17/2019 10/17/2019 at 8:55 AM 10/17/2019
Misc
Corrective Action Required
10/17/2019
-Sidewalk not approved on record -Submit as-graded plot plan to city -Lawn irrigation permit -Water meter lid must flush with grade level -Provide min 6” clearance from window trim to grade -No pendant allowed in master closet
Sidewalk Inspection Partial 10/18/2019
Misc
Informational
10/18/2019
Sidewalk forms and materials passed pre-inspection. 10/09/19
Sidewalk Inspection Passed 10/18/2019
Misc
Informational
10/18/2019
Sidewalk passed final inspection.
Occupancy Inspection - Codes Residential Temporary C of O 10/23/2019 10/23/2019 at 10:45 AM 10/23/2019
Misc
Corrective Action Required
10/17/2019
-Lawn irrigation permit -As-graded plot plan is required
Plot Plan Inspection Passed 11/1/2019 11/01/2019
Plot Plan Inspection Passed 11/17/2020 11/17/2020
Occupancy Inspection - Codes Residential Temporary C of O 11/17/2020
Misc
Corrective Action Required
10/23/2019
**TCO UNTIL 12-1-2020** -Obtain Lawn irrigation permit and back flow certification
Occupancy Inspection - Codes Residential Full C of O 12/11/2020
Misc
Resolved
12/11/2020
**TCO UNTIL 12-1-2020** -Obtain Lawn irrigation permit and back flow certification
Documents & Images
Date Uploaded File Type Document Name
01/23/2019 Letter Codes Residential Plan Review
01/25/2019 Letter Codes Residential Plan Review
04/03/2019 Receipt Receipt for transaction: 2019-001231
04/03/2019 Letter Codes Building Permit
04/04/2019 Plot Plan DOC040419-04042019093524
04/08/2019 Letter INSPECTION SUMMARY
04/08/2019 Letter INSPECTION SUMMARY
04/11/2019 Letter INSPECTION SUMMARY
04/11/2019 Letter INSPECTION SUMMARY
07/03/2019 Letter INSPECTION SUMMARY
07/03/2019 Letter INSPECTION SUMMARY
07/03/2019 Letter INSPECTION SUMMARY
07/11/2019 Letter INSPECTION SUMMARY
07/19/2019 Letter INSPECTION SUMMARY
07/19/2019 Letter INSPECTION SUMMARY
10/17/2019 Letter INSPECTION SUMMARY
10/17/2019 Letter INSPECTION SUMMARY
10/23/2019 Letter Codes Temporary Certificate of Occupancy
10/29/2019 Park Ridge 4th Plat Lot 315 FG 19.1025
11/01/2019 Letter INSPECTION SUMMARY
03/26/2020 Letter Codes 140 Day Letter
11/16/2020 Plot Plan As Graded Plot Plan
11/17/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter Codes Temporary Certificate of Occupancy
12/11/2020 Letter Codes Final Certificate of Occupancy
12/11/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home