Permit Application Status

PRRES20183692


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20183692
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW HOUSE SUSPENDED SLAB FINISHED AND UNFINISHED BASEMENT COVERED DECK
10/25/2018
11/01/2018
03/02/2020
Locations
Contacts
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
UNITED ELECTRIC COMPANY, Address:PO BOX 723, Phone:(816) 795-2744  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
chad@mcgraw-homes.com  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 10/29/2018 10/30/2018
Brandon Kalwei
Plot Plan Review Approved 10/29/2018 10/29/2018
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,166.83 $1,166.83 Paid 11/01/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/01/2018
8331507-Sewer Connection Fee $450.00 $450.00 Paid 11/01/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 11/01/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 11/01/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 11/7/2018 11/7/2018 at 1:30 PM 11/07/2018
Misc
Corrective Action Required
11/07/2018
NO CITY-APPROVED PRINTS FOUND ON SITE. NOT READY.
Footing Inspection - Residential Passed 11/7/2018 11/7/2018 at 3:35 PM 11/07/2018
Misc
Resolved
11/07/2018
NO CITY-APPROVED PRINTS FOUND ON SITE. NOT READY.
Sewer Service Inspection - R Passed 11/27/2018 (1:00) 11/27/2018 11/27/2018
Water Service Inspection - R Passed 11/28/2018 11/28/2018 at 12:45 PM 11/28/2018
Underslab Plumbing Inspection - Residential Failed 12/17/2018 12/17/2018 at 8:20 AM 12/17/2018
Misc
Corrective Action Required
12/17/2018
-PROTECT WATER LINE THROUGH SLAB
Underslab Plumbing Inspection - Residential Passed 12/18/2018 12/17/2018 12/17/2018
Misc
Resolved
12/17/2018
-PROTECT WATER LINE THROUGH SLAB
Suspended Slab Inspection Passed 2/12/2019 2/12/2019 at 11:45 AM 02/12/2019
Piers/Caissons Inspection - Residential Passed 4/11/2019 4/11/2019 at 9:20 AM 04/11/2019
All Rough Inspection - Residential Failed 4/24/2019 4/24/2019 04/24/2019
Misc
Corrective Action Required
04/24/2019
FRAMING: -Fb floor penetrations by central vac -Move roof support strut above laundry to bearing wall -Brace lvl beam ends from rotation -Fill in with wood gap behind deck door hinges and at strike plate side per security code -Nail hanger at stair -Install (3)2x4 support for kitchen lvl point load down to basement stair grade beam -Install stud shoes for over-bored studs in basement bedroom -Install joist hangers below master shower -Double joist not aligned with bearing fireplace/bedroom wall. Install blockings between double joist every 4 ft -Install security blocking for basement walkout door ELECTRICAL: -Wiring at master shower -Ducting directly above panel -Cannot break the sub panel bar. **OK TO INSULATE
Electrical Service Inspection Passed 4/24/2019 4/24/2019 04/24/2019
Gas Service Inspection - Residential Passed 4/24/2019 4/24/2019 04/24/2019
All Rough Inspection - Residential Failed 5/1/2019 5/1/2019 at 9:35 AM 05/01/2019
Misc
Corrective Action Required
04/24/2019
FRAMING: -Fill in with wood gap behind deck door hinges and at strike plate side per security code -Install (3)2x4 support for kitchen lvl point load down to basement stair grade beam **Reinstall electrical. Should have moved the electrical wiring out of the way so the studs can be installed without excessive notching -Double joist not aligned with bearing fireplace/bedroom wall. Install blockings between double joist every 4 ft **blocking at wrong place. Mkae sure to place blockings at locations of the point loads. The bearing wall mentioned in this is the one that has the central vac pipe going down **OK TO INSULATE
All Rough Inspection - Residential Failed 5/2/2019 at 1:40 PM 05/02/2019
Misc
Corrective Action Required
05/01/2019
FRAMING: -Fill in with wood gap behind deck door hinges and at strike plate side per security code -Double joist not aligned with bearing fireplace/bedroom wall. Install blockings between double joist every 4 ft **blocking at wrong place. Mkae sure to place blockings at locations of the point loads. The bearing wall mentioned in this is the one that has the central vac pipe going down **OK TO INSULATE
All Rough Inspection - Residential Passed 5/3/2019 5/3/2019 at 9:00 AM 05/03/2019
Misc
Resolved
05/03/2019
FRAMING: -Fill in with wood gap behind deck door hinges and at strike plate side per security code -Double joist not aligned with bearing fireplace/bedroom wall. Install blockings between double joist every 4 ft **blocking at wrong place. Mkae sure to place blockings at locations of the point loads. The bearing wall mentioned in this is the one that has the central vac pipe going down **OK TO INSULATE
Piers/Caissons Inspection - Residential Failed 6/26/2019 (1:30) 6/26/2019 at 1:50 PM 06/26/2019
Misc
Corrective Action Required
06/26/2019
NOT SURE WHAT THE PIERS, BESIDE THE DECK PIERS, ARE FOR. HAVE IT APPROVED ON THE PLOT PLAN. POUR AT OWN RISK
Piers/Caissons Inspection - Residential Passed 07/25/2019
Misc
Resolved
07/25/2019
NOT SURE WHAT THE PIERS, BESIDE THE DECK PIERS, ARE FOR. HAVE IT APPROVED ON THE PLOT PLAN. POUR AT OWN RISK
Occupancy Inspection - Codes Residential Failed 7/25/2019 7/25/2019 at 10:35 AM 07/25/2019
Misc
Corrective Action Required
07/25/2019
-Sidewalk and driveway not approved on record -Final grade, sod, splashblocks, sump pump extension -Access to cooktop gas shut off valve -Install stair light -Provide clean out for furnace condensate drainage -Insulate wall at basement walkout door -Screw exterior doors embedded brace to studs **You and Judd need to work out resolving the mud flowed onto the adjacent house lot on the east
Sidewalk Inspection Passed 6/5/2019 (P.M.) 6/5/2019 07/29/2019
Informational
06/06/2019
Sidewalk-forms and materials passed pre-inspection.
Misc
Informational
07/29/2019
Sidewalk- passed final inspection .
Driveway Inspection Passed 5/29/2019 (P.M.) 5/29/2019 07/29/2019
Misc
Informational
05/30/2019
Driveway/Walkway Pre- inspection forms and materials passed.
Misc
Informational
07/29/2019
Driveway-passed final inspection .
Occupancy Inspection - Codes Residential Failed 8/2/2019 8/2/2019 at 1:40 PM 08/02/2019
Misc
Corrective Action Required
07/25/2019
-Final grade, sod, splashblocks, sump pump extension
Misc
Corrective Action Required
08/02/2019
TEMPORARY OR PERMANENT EROSION CONTROL REQUIRED AT ALL DOWN-SLOPING BOUNDARIES FOR TCO TO BE ISSUED.
Occupancy Inspection - Codes Residential Temporary C of O 8/6/2019 8/6/2019 at 3:00 PM 08/06/2019
Misc
Corrective Action Required
08/02/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; 3`-0 SPLASH BLOCKS OR LEADERS; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE; AC CONDENSER PAD LEVEL & 3" ABOVE GRADE.
Misc
Resolved
08/06/2019
TEMPORARY OR PERMANENT EROSION CONTROL REQUIRED AT ALL DOWN-SLOPING BOUNDARIES FOR TCO TO BE ISSUED.
Driveway Inspection Passed 7/29/2019 7/29/2019 10/11/2019
Misc
Informational
05/30/2019
Driveway/Walkway Pre- inspection forms and materials passed.
Misc
Informational
10/11/2019
Driveway - passed final inspection.
Sidewalk Inspection Passed 7/29/2019 7/29/2019 10/11/2019
Misc
Informational
10/11/2019
Sidewalk - passed final inspection.
Occupancy Inspection - Codes Residential Full C of O 3/2/2020 at 8:45 AM 03/02/2020
Misc
Resolved
03/02/2020
Documents & Images
Date Uploaded File Type Document Name
10/25/2018 Letter Codes Residential Plan Review
11/01/2018 Receipt Receipt for transaction: 2018-007082
11/01/2018 Letter Codes Building Permit
11/02/2018 Plot Plan DOC110218-11022018084519
11/07/2018 Letter Inspection Summary
11/07/2018 Letter Inspection Summary
11/27/2018 Letter INSPECTION SUMMARY
12/17/2018 Letter INSPECTION SUMMARY
02/12/2019 Letter INSPECTION SUMMARY
04/11/2019 Letter INSPECTION SUMMARY
04/24/2019 Letter INSPECTION SUMMARY
04/24/2019 Letter INSPECTION SUMMARY
04/24/2019 Letter INSPECTION SUMMARY
05/01/2019 Letter INSPECTION SUMMARY
05/02/2019 Letter INSPECTION SUMMARY
05/03/2019 Letter INSPECTION SUMMARY
06/06/2019 Letter DE-Daily Inspection Summary
06/26/2019 Letter INSPECTION SUMMARY
07/25/2019 Letter INSPECTION SUMMARY
07/25/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
08/02/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter Codes Temporary Certificate of Occupancy
08/06/2019 Letter Codes Temporary Certificate of Occupancy
03/02/2020 Letter Field Certificate of Occupancy
03/02/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home