Summary
PRRES20181747
Building Permit - Residential
Certificate of Occupancy
ASPEN HOMEBUILDERS LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
06/07/2018
06/18/2018
09/22/2021
Locations
Contacts
ASPEN HOME BUILDERS LLC, Address:6618 ROYAL ST #B, Phone:(816) 507-0123  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
ASPEN HOMEBUILDERS LLC, Address:6618 ROYAL ST STE B  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/11/2018 06/18/2018
Steve Conrick
Property boundary
Corrective Action Required
06/11/2018

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. ***All property lines must match the bearings shown on the plat***
Right-of-way
Corrective Action Required
06/11/2018

The right-of-way with dimensions must be provided on the plot plan. ***Add ROW information and street name***
Basement opening elevations
Corrective Action Required
06/11/2018

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. ***List the MBOE as shown on the Master Drainage Plan***
As-graded plot plan
Corrective Action Required
06/11/2018

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Please put "AS-GRADED PLOT PLAN REQUIRED PRIOR TO SODDING" in a bubble.***
Residential Plan Review Approved 06/11/2018 06/12/2018
Brandon Kalwei
01 One (1) complete permit application
Corrective Action Required
06/07/2018

One (1) complete permit application
07 Identify emergency escape openings from bedrooms
Corrective Action Required
06/07/2018

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
12 Detail required separation between garage and living area including door
Corrective Action Required
06/07/2018

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) does not specify self closing
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,012.58 $1,012.58 Paid 06/18/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 06/18/2018
8331507-Sewer Connection Fee $630.00 $630.00 Paid 06/18/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 06/18/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 06/18/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/5/2018 7/5/2018 at 9:00 AM 07/05/2018
Sewer Service Inspection - R Passed 8/3/2018 (10:45) 8/3/2018 at 11:30 AM 08/03/2018
Water Service Inspection - R Passed 8/6/2018 8/6/2018 at 1:30 PM 08/06/2018
Underslab Plumbing Inspection - Residential Passed 8/9/2018 8/9/2018 at 9:30 AM 08/09/2018
Piers/Caissons Inspection - Residential Passed 9/13/2018 9/13/2018 at 10:10 AM 09/13/2018
All Rough Inspection - Residential Failed 10/26/2018 10/26/2018 10/26/2018
Misc
Corrective Action Required
10/26/2018
Incomplete inspection- Inspection denied for erosion control at the rear , none in place. Inspection incomplete due to amount of issues including Erosion control. address and see below. -Heat ducts hanging below ceiling 2nd floor. Support and secure per code. -Dwv in south exterior wall needs mid support , at landing area. All dwv shall have a mid support between floors. -Flue clearance at 2nd floor flue chase. Complete fur down for chase. Fire stop with 3/4” plywood not siding. -Tie rafters to ceiling joist over mstr bed. -Lateral brace ceiling joist at the ends front side of mstr. -Snow block all step flashing -Perlin over rear rear bedroom. -Strap top plates sw corner of mstr bedroom at 2x6 wall & at Ne corner at Bath wall. -Support heels of stair stringers. -Electrical Box and open wiring not furred out base of stairs 1st floor. -No fireplace installed. -Secure wardlfex per code at fireplace. -No security blocking. -Fire stopping rear breakfast room each corner. -Cut floor joist breakfast room for DWV. -Portal framing rear great room wall. -Install bearing studs per plans. Load points. -Cut floor joist over garage entry hall. -Portal framing per plans rear of house.CS_PF -Firstop with 3/4” flue chase 1st floor. -Firestop garage chase , 1/2” installed open gaps. -Support DWV 48”. -Lvl header over mud room not on the plans. Header cut short and not connecting to king stud. -Wall bracing not install at all locations 1st floor. 2nd- -Back wall of front bedroom is not a bearing wall on the plans. Lands in the middle of the floor joist below. - check wall bracing over 45°. -Master bedroom/closet bath has bearing walls not labeled on plans. -No garage beam post installed.
All Rough Inspection - Residential Failed 11/14/2018 11/14/2018
Misc
Corrective Action Required
10/26/2018
-Flue clearance at 2nd floor flue chase. Complete fur down for chase. Fire stop with 3/4” plywood not siding. flue clearance on 1st,2nd floors. -Perlin over rear rear bedroom. no purlin installed , raftes have a vaulted ceiling load on them. -Secure wardlfex per code at fireplace. incomplete -Lvl header over mud room not on the plans. ** This is a 2 story wall, plan shows a single window a tripple is installed (over 4' )provide Engineering on the header installed not according to plans. -Back wall of front bedroom is not a bearing wall on the plans. Lands in the middle of the floor joist below. ...Check rear bedroom wall ceiling joist land on non-bearing wall. -missing dbl joist over kitchen. -Missing ebam post in bsmt at stair wall.
All Rough Inspection - Residential Failed 11/29/2018 11/29/2018 11/29/2018
Misc
Corrective Action Required
11/14/2018
-Flue clearance at 2nd floor flue chase. Clearance to 2x4 needs to be 1” And to 3/4” smart trim. Ok to insulate
Electrical Service Inspection Passed 11/29/2018 11/29/2018 11/29/2018
Gas Service Inspection - Residential Passed 11/29/2018 11/29/2018 11/29/2018
All Rough Inspection - Residential Passed 12/4/2018 12/4/2018 12/04/2018
Misc
Resolved
12/04/2018
-Flue clearance at 2nd floor flue chase. Clearance to 2x4 needs to be 1” And to 3/4” smart trim. Ok to insu
Driveway Inspection Partial 2/13/2019 2/13/2019 02/13/2019
Misc
Informational
02/13/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 2/13/2019 2/13/2019 02/13/2019
Misc
Informational
02/13/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 2/18/2019 03/05/2019
Misc
Informational
02/13/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 2/18/2019 03/05/2019
Misc
Informational
02/13/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 3/18/2019 3/18/2019 03/18/2019
Misc
Corrective Action Required
03/18/2019
-Landing at patio steps needs to be either same as the 1st step or 36" -no light switch at basement level. switch for stair lighting needs to be a each level. - check all exterior items, gutters ,paint, splashblocks, final grade, sod.
Occupancy Inspection - Codes Residential Temporary C of O 3/20/2019 3/20/2019 03/20/2019
Misc
Corrective Action Required
03/18/2019
- check all exterior items, gutters ,paint, splashblocks, final grade, sod.
Occupancy Inspection - Codes Residential Temporary C of O 5/20/2019 05/16/2019
Misc
Corrective Action Required
03/20/2019
- check all exterior items, gutters ,paint, splashblocks, final grade, sod. Extend to 6/15
Occupancy Inspection - Codes Residential Temporary C of O 6/12/2019 06/12/2019
Misc
Corrective Action Required
05/16/2019
sewer location devise needs to be installed flush with grade, lying on top of sod. Submit As-Graded-Plot plan. see original plot plan submitted with permit. Contact Steve Conrick 969-1200 for questions regarding plot plan Tco extended for plot plan.
Plot Plan Inspection Passed 6/21/2019 06/21/2019
Occupancy Inspection - Codes Residential Failed 6/28/2019 06/28/2019
Misc
Corrective Action Required
06/12/2019
sewer location devise needs to be installed flush with grade, lying on top of sod. Tco extended
Occupancy Inspection - Codes Residential Full C of O 09/22/2021
Misc
Resolved
09/22/2021
sewer location devise needs to be installed flush with grade, lying on top of sod. Tco extended
Documents & Images
Date Uploaded File Type Document Name
06/07/2018 Letter Codes Residential Plan Review
06/11/2018 Letter Codes Residential Plan Review
06/18/2018 Receipt Receipt for transaction: 2018-003976
06/18/2018 Letter Codes Building Permit
06/21/2018 Plot Plan DOC062118-06212018113511
07/05/2018 Letter Inspection Summary
08/03/2018 Letter Inspection Summary
08/06/2018 Letter Inspection Summary
08/09/2018 Letter Inspection Summary
09/13/2018 Letter Inspection Summary
10/26/2018 Letter Inspection Summary
11/14/2018 Letter INSPECTION SUMMARY
11/29/2018 Letter INSPECTION SUMMARY
11/29/2018 Letter INSPECTION SUMMARY
11/29/2018 Letter INSPECTION SUMMARY
11/29/2018 Letter INSPECTION SUMMARY
02/13/2019 Letter INSPECTION SUMMARY
02/13/2019 Letter INSPECTION SUMMARY
03/05/2019 Letter INSPECTION SUMMARY
03/05/2019 Letter INSPECTION SUMMARY
03/18/2019 Letter INSPECTION SUMMARY
03/20/2019 Letter Codes Temporary Certificate of Occupancy
05/16/2019 Letter Codes Temporary Certificate of Occupancy
05/16/2019 Letter INSPECTION SUMMARY
06/12/2019 Letter Codes Temporary Certificate of Occupancy
06/21/2019 Letter INSPECTION SUMMARY
06/21/2019 DOC062119-06212019163748
06/28/2019 Letter INSPECTION SUMMARY
09/22/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home