Permit Application Status

PRRES20181586


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20181586
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
05/23/2018
06/01/2018
06/20/2022
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/19/2018 06/19/2018
Steve Conrick
Plot Plan Review Approved 05/29/2018 05/29/2018
Troy Thompson
Residential Plan Review Approved 05/25/2018 05/25/2018
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
05/23/2018

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) not shown in bedroom #3.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $886.39 $886.39 Paid 06/01/2018
Right of Way Permit Fee $75.00 $75.00 Paid 06/01/2018
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/01/2018
Water Tap Fee $3,343.00 $3,343.00 Paid 06/01/2018
Water Meter Fee $431.83 $431.83 Paid 06/01/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 6/28/2018 (10:00) 6/28/2018 at 9:50 AM 06/28/2018
Misc
Corrective Action Required
06/28/2018
THE PIER AT NE BASEMENT CORNER SHALL BE 4'X4'X16" DEEP **OK TO POUR THE REST OF THE FOOTING
Footing Inspection - Residential Passed 6/28/2018 (1:45) 6/28/2018 at 1:55 PM 06/28/2018
Misc
Resolved
06/28/2018
THE PIER AT NE BASEMENT CORNER SHALL BE 4'X4'X16" DEEP **OK TO POUR THE REST OF THE FOOTING
Erosion Control Inspection Residential Failed 7/19/2018 07/19/2018
Misc
Corrective Action Required
07/19/2018
-RESTORE EROSION CONTROL ALONG STREET AND PROVIDE 3/4" GRAVEL FILTER AT LOT ENTRANCE NO FURTHER INSPECTION IF EROSION CONTROL IS NOT IN COMPLIANCE
Underslab Plumbing Inspection - Residential Passed 7/19/2018 7/19/2018 at 10:55 AM 07/19/2018
Water Service Inspection - R Passed 7/25/2018 (1:00) 7/25/2018 at 1:25 PM 07/25/2018
Sewer Service Inspection - R Passed 7/25/2018 (9:30) 7/25/2018 at 9:20 AM 07/25/2018
Piers/Caissons Inspection - Residential Passed 9/27/2018 (8:00) 9/27/2018 at 9:15 AM 09/27/2018
Driveway Inspection Partial 10/1/2018 10/1/2018 at 12:35 PM 10/02/2018
Informational
10/02/2018
The driveway has been formed and appears to have 4" of compacted rock. Everthing looks good and is ready to pour.Steve Robbins 10/02/2018 8:27 AM
Sidewalk Inspection Partial 10/1/2018 10/1/2018 at 12:40 PM 10/02/2018
PW-Misc
Informational
10/02/2018
The sidewalk has been formed and has 4" of rock that has been compacted. At the end of the property line there is a MH that needs to be raised up, I am going to speak with Holthouse about this situation. I told them they can pour up to 2 panels before the MH.Steve Robbins 10/02/2018 8:34 AM
Electrical Service Inspection Passed 10/15/2018 10/15/2018 10/15/2018
Gas Service Inspection - Residential Passed 10/15/2018 10/15/2018 10/15/2018
All Rough Inspection - Residential Failed 10/15/2018 10/15/2018 at 9:45 AM 10/15/2018
Misc
Corrective Action Required
10/15/2018
**RE-ESTABLISH EROSION CONTROL FRAMING: -Plan does not match construction. See foundation wall layout and span of 16” I beam. -Nail garage portal wall sheathing at seams and sill plate -Install full stud support under front bedroom ridge beam -Nail corner studs per code -Front bedroom studs not continuous from floor to ceiling -Studs not continuous rear master bedroom -Fb fireplace space from roof -Reduce valley rafter span above living room -Deck floor framing -Anchor garage steel column and frame around column for fire protection -Install collar ties per code above garage -Solidblock all cantilevered joists -Toe nail all joists to wall top plates and sill plates -Seal all penetrations of ceiling joist return air space -Fb basement wall space vertically at ten ft or less interval -Install triple joist under front bedroom ridge beam point load MECHANICAL: -Seal duct joints in basement bedroom PLUMBING: -Protect plumbing in basement laundry ELECTRICAL: -Wiring outside wall space at basement laundry **DO NOT INSULATE
All Rough Inspection - Residential Failed 11/6/2018 11/6/2018 11/06/2018
Misc
Corrective Action Required
10/15/2018
NO CORRECTIONS MADE, SEVERAL SUBS ON THE JOB, PLANS STILL DON'T MATCH. DO NOT CALL FOR RE-INSPECTION UNTIL DESIGN PROFESSIONAL OF RECORD ADDRESSES THE PLAN. FRAMING: -Plan does not match construction. See foundation wall layout and span of 16” I beam. -Nail garage portal wall sheathing at seams and sill plate -Install full stud support under front bedroom ridge beam -Nail corner studs per code -Front bedroom studs not continuous from floor to ceiling -Studs not continuous at rear master bedroom -Fb fireplace space from roof -Reduce valley rafter span above living room -Deck floor framing not framed per plan -Anchor garage steel column and frame around column for fire protection -Install collar ties per code above garage -Solidblock all cantilevered joists -Toe nail all joists to wall top plates and sill plates -Seal all penetrations of ceiling joist return air space -Fb basement wall space vertically at ten ft or less interval -Install triple joist under front bedroom ridge beam point load MECHANICAL: -Seal duct joints in basement bedroom PLUMBING: -Protect plumbing in basement laundry ELECTRICAL: -Wiring outside wall space at basement laundry **DO NOT INSULATE
All Rough Inspection - Residential Failed 11/13/2018 11/13/2018 11/13/2018
Misc
Corrective Action Required
11/06/2018
FRAMING: -Nail garage portal wall sheathing at still and break in the sheathing. -Solid Block garage cantilever. -Seal around fireblocking/ penetrations in fireblocking in basement finish areas. Okay to insulate
All Rough Inspection - Residential Passed 11/21/2018 11/21/2018 at 9:00 AM 11/21/2018
Misc
Resolved
11/21/2018
FRAMING: -Nail garage portal wall sheathing at still and break in the sheathing. -Solid Block garage cantilever. -Seal around fireblocking/ penetrations in fireblocking in basement finish areas. Okay to insulate
Driveway Inspection Passed 4/10/2019 at 9:00 AM 05/07/2019
Misc
Informational
05/07/2019
The driveway has been poured and appears to meet all city standards.
Sidewalk Inspection Passed 5/7/2019 at 1:00 PM 05/07/2019
PW-Misc
Informational
10/02/2018
The sidewalk has been formed and has 4" of rock that has been compacted. At the end of the property line there is a MH that needs to be raised up, I am going to speak with Holthouse about this situation. I told them they can pour up to 2 panels before the MH.Steve Robbins 10/02/2018 8:34 AM
Misc
Informational
05/07/2019
The remainder of the sidewalk has been poured and the sanitary lid has been adjusted to the grade of the sidewalk.
Erosion Control Inspection Residential Passed 12/06/2019
Misc
Resolved
12/06/2019
-RESTORE EROSION CONTROL ALONG STREET AND PROVIDE 3/4" GRAVEL FILTER AT LOT ENTRANCE NO FURTHER INSPECTION IF EROSION CONTROL IS NOT IN COMPLIANCE
Occupancy Inspection - Codes Residential Failed 12/6/2019 12/6/2019 at 8:45 AM 12/06/2019
Misc
Corrective Action Required
12/06/2019
**NO ACCESS TO HOUSE. LOCKBOX CODE DOES NOT WORK. ATTEMPTED TO CONTACT BUILDER BUT UNSUCCESSFUL. -Install tamper-proof caps at AC valves -Raise AC support bed to min 3” above grade -Seal exterior wall penetrations, seal above meter and AC disconnect -Locate sewer tracer wire and install the sewer tracer box -Provide min 3 ft discharge at downspouts and sump pump discharge -Install backyard flood light -Deck: reframe to eliminate the deck floor load off the cantilevered joists. Get engineer to involve if you don;'t know how to do it; install two lag screws at ends of ledger board **NO ACCESS TO HOUSE
Occupancy Inspection - Codes Residential Failed 6/16/2020 6/16/2020 at 10:20 AM 06/16/2020
Misc
Corrective Action Required
12/06/2019
-Obtain lawn irrigation permit -Remove all debris from storm inlet -Provide full support underneath west deck post -Install backyard flood light -Install water hammering arrestor for dishwasher -Install anti backflow device at basement hose bib -Receptacle located within six ft of the wet bar sink must be gfci-protected -Screw the basement exterior door embedded brace into studs with 3” screws -Remove paper facing from insulation -Cut off the excess grounding rebar
Occupancy Inspection - Codes Residential Failed 6/23/2020 6/23/2020 at 8:20 AM 06/23/2020
Misc
Corrective Action Required
06/16/2020
-Remove all debris from storm inlet -Provide full support underneath west deck post -Install water hammering arrestor for dishwasher -Install anti backflow device at basement hose bib
Occupancy Inspection - Codes Residential Failed 12/27/2021 12/27/2021 12/27/2021
Misc
Corrective Action Required
06/23/2020
-Remove all debris from storm inlet -Provide full support underneath west deck post -Install water hammering arrestor for dishwasher -Install anti backflow device at basement hose bib **12/27-No one is at home. The house is currently occupied without an issued certificate of occupancy, in violation of the city ordinance. Please correct the above deficiencies and schedule an inspection as soon as possible.
Occupancy Inspection - Codes Residential Failed 1/7/2022 1/7/2022 01/07/2022
Misc
Corrective Action Required
12/27/2021
-Remove all debris from storm inlet
Occupancy Inspection - Codes Residential Full C of O 06/20/2022
Misc
Resolved
06/20/2022
Documents & Images
Date Uploaded File Type Document Name
05/23/2018 Letter Codes Residential Plan Review
06/01/2018 Receipt Receipt for transaction: 2018-003359
06/01/2018 Letter Codes Building Permit
06/05/2018 Plans DOC060518-013
06/15/2018 Plot Plan SKM_C36818061509400
06/15/2018 Plot Plan Lot 46 Walkout
06/20/2018 Plot Plan Plot plan for walkout basement
06/28/2018 Letter Inspection Summary
06/28/2018 Letter Inspection Summary
07/19/2018 Letter Inspection Summary
07/25/2018 Letter Inspection Summary
09/27/2018 Letter Inspection Summary
10/02/2018 Letter DE-Daily Inspection Summary
10/02/2018 Letter DE-Daily Inspection Summary
10/15/2018 Letter Inspection Summary
11/06/2018 Letter Inspection Summary
11/13/2018 Letter INSPECTION SUMMARY
11/21/2018 Letter INSPECTION SUMMARY
05/07/2019 Letter DE-Daily Inspection Summary
05/07/2019 Letter DE-Daily Inspection Summary
12/06/2019 Letter INSPECTION SUMMARY
12/06/2019 Letter INSPECTION SUMMARY
06/16/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
12/17/2021 Letter Codes 10 Day Letter
12/27/2021 Letter INSPECTION SUMMARY
01/07/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter Field Certificate of Occupancy
06/20/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home