Permit Application Status

PRRES20180140


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20180140
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
01/18/2018
02/06/2018
02/26/2019
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:1248 SW WYSTERIA DR  
SCOTT PRIER HOMES LLC, Address:404 SE HACKAMORE DR, Phone:(816) 509-8302  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
HOLSEY ELECTRIC, Inc, Address:1637 NW 100 RD, Phone:(816) 697-2112  
SUBURBAN PLUMBING, Address:20124 HOPS CREEK DR, Phone:(816) 985-0259  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 01/22/2018 02/02/2018
Brandon Kalwei
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
01/19/2018

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) garage and unfinished basement do not have sq. ft.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
01/19/2018

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) if the bedroom/study room is going to be a bedroom it needs to have an egress window labled
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
01/19/2018

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)if the bedroom/study room is going to be a bedroom it needs to have smoke detector inside room and smoke/carbon outside of room.
16 Identify location(s) of vertical supports and purlins.
Corrective Action Required
01/19/2018

Identify location(s) of vertical supports and purlins. (IRC Section R802.5.1) did not see any purlins labled. do you not need them?
17 Specification of rafter ties or ridge beam design.
Corrective Action Required
01/19/2018

Specification of rafter ties or ridge beam design. (IRC Section 802.3.1) did not see on plans
19 Footings, column pads, piers and grade beams - dimensions
Corrective Action Required
01/19/2018

Footings, column pads, piers and grade beams - dimensions. (IRC Section R403) no grade beams?
20 Footings, column pads, piers and grade beams - reinforcement
Corrective Action Required
01/19/2018

Footings, column pads, piers and grade beams - reinforcement size and spacing. no grade beams?
28 Identify location, size, and material of all beams, girders and vertical
Corrective Action Required
01/19/2018

Identify location, size, and material of all beams, girders and vertical supports. load path does not transfer down from the roof to the master bathroom opening.
35 Specify acceptable material and size of exterior sheathing.
Corrective Action Required
01/19/2018

Specify acceptable material and size of exterior sheathing. (IRC SEction R703) did not see on plans
Plot Plan Review Approved 01/22/2018 01/19/2018
Troy Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,122.81 $1,122.81 Paid 02/06/2018
Right of Way Permit Fee $75.00 $75.00 Paid 02/06/2018
8331507-Sewer Connection Fee $600.00 $600.00 Paid 02/06/2018
Water Tap Fee $3,343.00 $3,343.00 Paid 02/06/2018
Water Meter Fee $431.83 $431.83 Paid 02/06/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/16/2018 2/16/2018 at 3:35 PM 02/16/2018
Sewer Service Inspection - R Passed 3/7/2018 3/8/2018 at 8:10 AM 03/08/2018
Water Service Inspection - R Passed 3/7/2018 3/8/2018 at 8:05 AM 03/08/2018
Underslab Plumbing Inspection - Residential Passed 3/14/2018 at 10:30 AM 03/14/2018
Gas Service Inspection - Residential Passed 5/25/2018 05/25/2018
Electrical Service Inspection Passed 5/25/2018 05/25/2018
All Rough Inspection - Residential Failed 5/25/2018 5/25/2018 at 10:15 AM 05/25/2018
Misc
Corrective Action Required
05/25/2018
FRAMING: -Fur out wall for R-13 at garage wall return air -Support top of hip rafter above mud -Support hip above garage -Install attic access for roof above garage Nail together studs supporting the front porch beam -Fb vertical spaces in garage from joist space -Install proper hangers for double and triple joist Nail cross beam to adjacent stud at rear bathroom -Min 3 studs nailed together and solidblock underneath I beam point load at dining angled wall -Have engineer address brace wall at rear greatroom corner not per plan -Land roof support to bearing wall; or double joist underneath PLUMBING: -Stud shoe at kitchen exterior wall and all exterior wall where bored more than 40%; strap top plates bored more than 50% ***OK TO INSULATE
All Rough Inspection - Residential Failed 6/1/2018 6/1/2018 at 9:00 AM 06/01/2018
Misc
Corrective Action Required
05/25/2018
FRAMING: -Nail cross 2x4 beam to adjacent stud at rear bathroom -Have engineer address brace wall at rear greatroom corner not per plan PLUMBING: -Strap top plates bored more than 50% at exterior walls ***OK TO INSULATE
All Rough Inspection - Residential Partial 6/4/2018 6/4/2018 at 11:45 AM 06/04/2018
Misc
Corrective Action Required
06/01/2018
FRAMING: -Have engineer address brace wall at rear greatroom corner not per plan ***OK TO ROCK
Piers/Caissons Inspection - Residential Passed 6/14/2018 6/14/2018 at 10:05 AM 06/14/2018
Driveway Inspection Partial 7/9/2018 7/9/2018 at 1:10 PM 07/09/2018
Informational
07/09/2018
Brice Lawson 07/09/2018 1:59 PM The driveway approach forms have been set. It appears that the base rock for the approach has been compacted. The contractor plans to install the expansion joint filler and 4K KCMMB conrete tomorrow. I asked the contractor to submit a copy of the delivery ticket for the concrete.
Driveway Inspection Passed 7/17/2018 at 2:05 PM 07/17/2018
Informational
07/11/2018
Brice Lawson 07/11/2018 3:57 PM The contractor submitted a copy of the concrete ticket that shows 4000# KCMMB concrete mix was used for the driveway approach.
Informational
07/17/2018
Brice Lawson 07/17/2018 2:51 PM The driveway approach has been installed. It appears to be a typical installation. The driveway approach is less than 36' wide in the ROW.
All Rough Inspection - Residential Passed 02/15/2019
Misc
Resolved
02/15/2019
FRAMING: -Have engineer address brace wall at rear greatroom corner not per plan ***OK TO ROCK
Occupancy Inspection - Codes Residential Failed 2/15/2019 2/15/2019 at 9:20 AM 02/15/2019
Misc
Corrective Action Required
02/15/2019
-OBTAIN LAWN IRRIGATION PERMIT AND SUBMIT TO THE CITY THE BACKFLOW TEST REPORT -LEVEL AND SET WATER METER LID -LOCATE SEWER TRACER WIRE AND INSTALL SEWER TRACER BOX -THE DECK BEAM SHALL BE ATTACHED TO POSTS WITH TW0 1/2" THROUGH BOLTS -INSTALL SECURITY STRIKE PLATE FOR REAR EXTERIOR DOOR -INSTALL WATER HAMMERING ARRESGTOR FOR THE DISH WASHER -ANCHOR BASEMENT STEEL COLUMN -SUPPORT THE JOIST ADJACENT TO THE B VENT IN BASEMENT -SLOPE THE B-VENT MIN 1/4" PER FT -THE RECEPTACLE IN MASTER BATH SHALL BE GFCI -ELECTRICIAN PLEASE READ THE NEC REQUIREMENT THAT THE HYDROTUB MOTOR RECEPTACLE CIRCUIT MUST BE INDIVIDUAL CIRCUIT, NOT SHARED WITH THE LAVATORY RECEPTACLE CIRCUIT. NEC 680.71
Occupancy Inspection - Codes Residential Temporary C of O 2/22/2019 at 8:40 AM 02/22/2019
Misc
Corrective Action Required
02/15/2019
-LEVEL AND SET WATER METER LID -LOCATE SEWER TRACER WIRE AND INSTALL SEWER TRACER BOX -SUPPORT THE JOIST ADJACENT TO THE B VENT IN BASEMENT **USE THE L BRACKET TO SUPPORT JOIST TO RIM -THE RECEPTACLE IN MASTER BATH SHALL BE GFCI **NEC REQUIRES **ALL** RECEPTCLES INSIDE THE BATHROOM SHALL BE GFCI-PROTECTED
Occupancy Inspection - Codes Residential Full C of O 2/26/2019 2/26/2019 at 9:55 AM 02/26/2019
Misc
Resolved
02/26/2019
-LEVEL AND SET WATER METER LID -LOCATE SEWER TRACER WIRE AND INSTALL SEWER TRACER BOX -SUPPORT THE JOIST ADJACENT TO THE B VENT IN BASEMENT **USE THE L BRACKET TO SUPPORT JOIST TO RIM -THE RECEPTACLE IN MASTER BATH SHALL BE GFCI **NEC REQUIRES **ALL** RECEPTCLES INSIDE THE BATHROOM SHALL BE GFCI-PROTECTED
Documents & Images
Date Uploaded File Type Document Name
01/19/2018 Letter Codes Residential Plan Review
02/06/2018 Receipt Receipt for transaction: 2018-000451
02/06/2018 Letter Codes Building Permit
02/07/2018 Plot Plan DOC020718-006
02/16/2018 Letter Inspection Summary
03/08/2018 Letter Inspection Summary
03/14/2018 Letter Inspection Summary
05/25/2018 Letter Inspection Summary
06/01/2018 Letter Inspection Summary
06/04/2018 Letter Inspection Summary
06/14/2018 Letter Inspection Summary
07/09/2018 Letter DE-Daily Inspection Summary
07/11/2018 Concrete Ticket For Driveway Approach
07/17/2018 Letter DE-Daily Inspection Summary
09/10/2018 Engineer Report/Study Prier Plan 9312 Wall Bracing Issue 6-4-18_
02/15/2019 Letter INSPECTION SUMMARY
02/15/2019 Letter INSPECTION SUMMARY
02/22/2019 Letter Codes Temporary Certificate of Occupancy
02/26/2019 Letter Field Certificate of Occupancy
02/27/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home