Permit Application Status

PRRES20173427


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20173427
Building Permit - Residential
Certificate of Occupancy
SBISA HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
10/16/2017
11/03/2017
08/06/2018
Locations
Contacts
SBISA HOMES INC, Address:29710 E WINDMILL RIDGE LN  
SBISA HOMES INC, Address:29710 WINDMILL RIDGE LN, Phone:(816) 697-3604  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/18/2017 11/03/2017
Kim Brennan
Legal description
Resolved
11/02/2017

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. *Can you please add an address.
Sidewalks
Resolved
11/02/2017

Sidewalks with deminsions must be provided on the plot plan. *Can you provide the ADA ramp location.
Residential Plan Review Approved 10/18/2017 10/25/2017
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
10/16/2017

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) no carbon monoxide detector shown outside of flex room
11 Designate R-value(s) for floors, walls, ceilings, roof/ceilings.
Corrective Action Required
10/16/2017

Designate R-value(s) for floors, walls, ceilings, roof/ceilings. (LSCO 7-802)
12 Detail required separation between garage and living area including door
Corrective Action Required
10/16/2017

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5)
15 Provide size, spacing, species, and grade of rafter, ceiling joist mater
Corrective Action Required
10/16/2017

Provide size, spacing, species, and grade of rafter, ceiling joist materials and ridge and valley members. (IRC Section R802)
16 Identify location(s) of vertical supports and purlins.
Corrective Action Required
10/16/2017

Identify location(s) of vertical supports and purlins. (IRC Section R802.5.1) unable to follow the load path
17 Specification of rafter ties or ridge beam design.
Corrective Action Required
10/16/2017

Specification of rafter ties or ridge beam design. (IRC Section 802.3.1)
19 Footings, column pads, piers and grade beams - dimensions
Corrective Action Required
10/16/2017

Footings, column pads, piers and grade beams - dimensions. (IRC Section R403) dimensionally locate column pads and the reinforcement size and spacing of column pads and all peirs.
20 Footings, column pads, piers and grade beams - reinforcement
Corrective Action Required
10/16/2017

Footings, column pads, piers and grade beams - reinforcement size and spacing.
28 Identify location, size, and material of all beams, girders and vertical
Corrective Action Required
10/16/2017

Identify location, size, and material of all beams, girders and vertical supports. unable to follow the load path
29 Identify joists under bearing partitions.
Corrective Action Required
10/16/2017

Identify joists under bearing partitions. (IRC Section R502.4)
30 Identify type of protection used in unfinished areas under
Corrective Action Required
10/16/2017

Identify type of protection used in unfinished areas under floor trusses. (IRC Section R501.3)
36 Identify interior load bearing walls.
Corrective Action Required
10/16/2017

Identify interior load bearing walls. (IRC Section R602)
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $917.64 $917.64 Paid 11/03/2017
Right of Way Permit Fee $75.00 $75.00 Paid 11/03/2017
8331507-Sewer Connection Fee $450.00 $450.00 Paid 11/03/2017
Water Tap Fee $3,343.00 $3,343.00 Paid 11/03/2017
Water Meter Fee $431.83 $431.83 Paid 11/03/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/14/2017 (2:00) 11/14/2017 at 2:10 PM 11/14/2017
Erosion Control Inspection Residential Failed 12/5/2017 12/05/2017
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/05/2017
EROSION CONTROL REQUIRED ALONG THE STREET AND GRAVEL AT DRIVEWAY. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 12/6/2017 12/5/2017 at 1:25 PM 12/05/2017
Water Service Inspection - R Passed 12/12/2017 (3:00) 12/12/2017 at 3:15 PM 12/12/2017
Sewer Service Inspection - R Partial 12/12/2017 12/12/2017
Sewer Service Inspection - R Passed 12/13/2017 at 2:40 PM 12/13/2017
Piers/Caissons Inspection - Residential Passed 1/26/2018 (11:00) 1/26/2018 at 11:15 AM 01/26/2018
Electrical Service Inspection Failed 3/14/2018 3/14/2018 03/14/2018
Corrective Action Required
03/14/2018
-Ground service. Make sure connection is accessible -Close excessive hole at bottom of service disconnect
Gas Service Inspection - Residential Passed 3/14/2018 3/14/2018 03/14/2018
Erosion Control Inspection Residential Failed 3/14/2018 03/14/2018
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/05/2017
EROSION CONTROL REQUIRED ALONG THE STREET AND GRAVEL AT DRIVEWAY. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. **YOU ARE REQUIRED TO MAINTAIN EROSION CONTROL AROUND YOUR PLOT THROUGHOUT THE CONSTRUCTION PHASE. I CANNOT ALLOW FURTHER INSPECTION UNTIL EROSION CONTROL IS IN COMPLIANCE
All Rough Inspection - Residential Failed 3/14/2018 3/14/2018 at 9:30 AM 03/14/2018
Corrective Action Required
03/14/2018
**EROSION CONTROL SHALL BE IN COMPLIANCE FRAMING: -Provide plan on site -Nail hanger at lvl-lvl connection above basement stair -Anchor steel column -Fb dead space at front basement bedroom -Fb basement wall space from furdown -Provide full bearing support for lvl point load in return air space outside master bedroom -Land roof support struts to bearing wall: above dryer, laundry/foyer; smaller master closet -Full blocking under lvl point load at stair -Brace ends of lvl beam above kitchen from rotation -Anchor sill plates within 12” of breaks MECHANICAL: -Pan off return air from fireplace space ELECTRICAL: -Wall receptacle spacing not compliant in basement -Protect SE cable at basement bed wall top plate -Receptacle within 25 ft of ac PLUMBING: -Protect refrigerator water line and wiring **OK TO INSULATE
All Rough Inspection - Residential Failed 3/22/2018 3/22/2018 at 8:50 AM 03/22/2018
Corrective Action Required
03/14/2018
FRAMING: -Provide plan on site **plan shows no footing under stair. Have engineer address support for the LVL beam. Also header LVL is not suuported to the longer LVL with hanger **have engineer address undersized I beams installed. Plan shows 10" I beams, not 8". -Anchor steel column **not done MECHANICAL: -Pan off return air from fireplace space **please seal the gap. FYI: future code being adopted by the city will not allow this. Ducting for return air; no joist/stud space for return air **OK TO INSULATE
All Rough Inspection - Residential Passed 3/29/2018 3/29/2018 at 10:30 AM 03/29/2018
Resolved
03/29/2018
FRAMING: -Provide plan on site **plan shows no footing under stair. Have engineer address support for the LVL beam. Also header LVL is not suuported to the longer LVL with hanger **have engineer address undersized I beams installed. Plan shows 10" I beams, not 8". -Anchor steel column **not done MECHANICAL: -Pan off return air from fireplace space **please seal the gap. FYI: future code being adopted by the city will not allow this. Ducting for return air; no joist/stud space for return air **OK TO INSULATE
Electrical Service Inspection Failed 4/18/2018 4/18/2018 at 11:51 AM 04/18/2018
Electrical Service Inspection Passed 4/20/2018 4/20/2018 at 9:40 AM 04/20/2018
Driveway Inspection Partial 6/19/2018 6/19/2018 at 9:35 AM 06/19/2018
Informational
06/19/2018
Jeremy Young 06/19/2018 9:39 AM Contractor has sufficient compacted rock base. They have been instructed to carry less than 2% cross slope for the ADA compliance. The expansion joint is present.
Driveway Inspection Failed 6/21/2018 at 2:00 PM 06/22/2018
Informational
06/22/2018
Jeremy Young 06/22/2018 2:04 PM Contractor has poured the driveway. The finish of the driveway is gouged and peeling due to rain on the finish before cured. I have informed the contractor to replace the approach.
Sidewalk Inspection Partial 6/28/2018 6/27/2018 at 2:00 PM 06/27/2018
Informational
06/27/2018
Jeremy Young 06/27/2018 2:14 PM Contractor has sufficient compacted rock. the cross slope is less than 2% which meets ADA requirements.
Driveway Inspection Partial 6/28/2018 6/27/2018 at 2:15 PM 06/27/2018
Informational
06/27/2018
Jeremy Young 06/27/2018 2:17 PM Contractor has torn out the drive approach. They have less than 2% cross slope which meets ADA compliance. They have the expansion joint and will add it.
Sidewalk Inspection Passed 6/29/2018 at 7:00 AM 07/05/2018
PW-Misc
Informational
07/05/2018
The sidewalk has passed inspection. Less than 2% slope.Steve Robbins 07/05/2018 9:54 AM
Driveway Inspection Passed 7/5/2018 at 7:15 AM 07/05/2018
Informational
07/05/2018
The driveway approach has now passed inspection.Steve Robbins 07/05/2018 9:59 AM
Occupancy Inspection - Codes Residential Failed 7/26/2018 7/26/2018 at 9:40 AM 07/26/2018
Misc
Corrective Action Required
07/26/2018
-Final grade sod splashblocks -Seal exterior lights, furnace in take&exhaust, exterior gfci receptacle, and all penetrations -Install gfci receptacle near AC -Block&reinforce deck posts near house -Lag deck beam to posts -The upper stair light switch not 2-way wired to the bottom stair light switch -Basement bath sink receptacle at tripping; ceiling led luminaire missing cover -Install security strike plate and fasten into studs with 3” screws -Provide combustion air openings per code -Provide gfci protection for basement washer receptacle -Pack in insulation to fireblock and protect TJI joists -Ufer and sewer clean out must be accessible
Occupancy Inspection - Codes Residential Failed 8/1/2018 08/01/2018
Misc
Corrective Action Required
07/26/2018
-Final grade sod splashblocks -Ufer and sewer clean out must be accessible
Erosion Control Inspection Residential Passed 08/06/2018
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/06/2018
EROSION CONTROL REQUIRED ALONG THE STREET AND GRAVEL AT DRIVEWAY. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. **YOU ARE REQUIRED TO MAINTAIN EROSION CONTROL AROUND YOUR PLOT THROUGHOUT THE CONSTRUCTION PHASE. I CANNOT ALLOW FURTHER INSPECTION UNTIL EROSION CONTROL IS IN COMPLIANCE
Occupancy Inspection - Codes Residential Full C of O 8/6/2018 at 9:20 AM 08/06/2018
Misc
Resolved
08/06/2018
-Final grade sod splashblocks -Ufer and sewer clean out must be accessible
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home