Permit Application Status

PRRES20173028


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20173028
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
HOUSE WITH COVERED PATIO
09/08/2017
09/25/2017
05/10/2018
Locations
Contacts
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210, Phone:(816) 524-5245  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/12/2017 09/20/2017
Nick Lightner
Easements
Resolved
09/20/2017

All easements with deminsions must be provided on the plot plan. *Can you please provide the utility easement in the rear of the yard.
Spot elevations
Resolved
09/20/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *Can you please provide more info in the rear of the yard. I am worried that the house maybe to low and it wont direct the water away from it. I did see the arrow, but maybe contours or extra elevation points.
City infrustructure
Resolved
09/20/2017

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. *Can you please double check to make sure that there is a storm lid located on the SW corner of the lot.
Residential Plan Review Approved 09/12/2017 09/11/2017
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $779.80 $779.80 Paid 09/25/2017
8331507-Sewer Connection Fee $330.00 $330.00 Paid 09/25/2017
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 09/25/2017
8350015-Water Meter Fee $431.83 $431.83 Paid 09/25/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 09/25/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/27/2017 (10:30) 9/27/2017 at 10:20 AM 09/27/2017
Sewer Service Inspection - R Passed 10/13/2017 (10:30) 10/13/2017 at 11:55 AM 10/13/2017
Water Service Inspection - R Partial 10/13/2017 (10:30) 10/13/2017 10/13/2017
Erosion Control Inspection Residential Failed 10/13/2017 10/13/2017
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/13/2017
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Failed 10/16/2017 10/16/2017 at 9:05 AM 10/16/2017
Misc
Corrective Action Required
10/16/2017
**DENIED INSPECTION DUE TO LACK OF EROSION CONTROL
Erosion Control Inspection Residential Failed 10/16/2017 10/16/2017
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/13/2017
EROSION CONTROL REQUIRED ALL AROUND LOT, INCLUDING DISTURBED SOIL/DIRT PILE. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 10/17/2017 10/16/2017 at 1:35 PM 10/16/2017
Misc
Resolved
10/16/2017
**DENIED INSPECTION DUE TO LACK OF EROSION CONTROL
Water Service Inspection - R Passed 10/16/2017 10/16/2017 10/16/2017
Erosion Control Inspection Residential Partial 10/16/2017 10/16/2017
DCM1 ESC REQUIRED NO FURTHER INSP
Partial Correction
10/16/2017
10/16-EROSION CONTROL IN COMPLIANCE
Driveway Inspection Partial 11/27/2017 11/27/2017 at 10:35 AM 11/27/2017
Driveway Inspection Passed 11/30/2017 at 10:20 AM 11/30/2017
Erosion Control Inspection Residential Failed 12/11/2017 12/11/2017
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/11/2017
DEFICIENT EROSION CONTROL INSTALLATION. REPAIR EROSION CONTROL. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Electrical Service Inspection Passed 12/11/2017 12/11/2017 12/11/2017
Gas Service Inspection - Residential Passed 12/11/2017 12/11/2017 12/11/2017
All Rough Inspection - Residential Failed 12/11/2017 12/11/2017 at 8:00 AM 12/11/2017
Misc
Corrective Action Required
12/11/2017
FRAMING: -Min 6'8" headroom clearance requird above stair near the front end of the diagonal lvl -Install full supports under lvl and all other beams at stair wall -Anchor within 12” of breaks and at interval no more than six ft (missing anchors) -Anchor garage portal wall sill plates -Add more nailing to H-frames or install straps -Nail corner studs w/ 16d@12" oc or equivalent nailing -Complete fur out for b vent in garage -Install collar ties above laundry&garage area -Brace lvl beam above living rm from rotation -Install hanger support for ceiling beam connections above front bed/bath wall -Block rear door stud and fill in gap at strike plate side per security code -Tempered glass window required adjacent to rear door -Fireblock fireplace space from roof PLUMBING: -Protect water line at master shower -Protect water at front bed/bath wall ***OK TO INSULATE
All Rough Inspection - Residential Failed 12/13/2017 12/13/2017 at 9:50 AM 12/13/2017
Misc
Corrective Action Required
12/11/2017
-Add more nailing to H-frames or install straps **min. 7 nails into H-frame&lvl per APA or just strap -Complete fur out for b vent in garage **need to fireblock opening at top -Install hanger support for ceiling beam connections above front bed/bath wall **the wall is not a bearing wall. not designed to carry the roof load. The 3x beam is. -Fill in gap at strike plate side per security code -Tempered glass window required adjacent to rear door ***OK TO INSULATE **About the stair headroom clearance, I OK with this, but next time you need to move the header a couple of inches to be fully compliant
All Rough Inspection - Residential Passed 12/18/2017 12/18/2017 at 11:35 AM 12/18/2017
Misc
Resolved
12/18/2017
-Add more nailing to H-frames or install straps **min. 7 nails into H-frame&lvl per APA or just strap -Complete fur out for b vent in garage **need to fireblock opening at top -Install hanger support for ceiling beam connections above front bed/bath wall **the wall is not a bearing wall. not designed to carry the roof load. The 3x beam is. -Fill in gap at strike plate side per security code -Tempered glass window required adjacent to rear door ***OK TO INSULATE **About the stair headroom clearance, I OK with this, but next time you need to move the header a couple of inches to be fully compliant
Occupancy Inspection - Codes Residential Failed 4/18/2018 4/18/2018 at 8:15 AM 04/18/2018
Misc
Corrective Action Required
04/18/2018
-INSPECTION DENIED DUE TO LACK OF EROSION CONTROL AND MUD ON THE STREET. I CALLED AND LEFT THE MESSAGE WEEKS AGO ABOUT THE EROSION CONTROL AND MUD ON THE STREET. I ALSO POSTED THE EROSION CONTROL SIGNAGE ON THE SAME DAY. NOTHING WAS DONE SINCE.
Erosion Control Inspection Residential Failed 4/18/2018 04/18/2018
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/11/2017
EROSION CONTROL AND STREET CLEANUP REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 5/1/2018 5/1/2018 at 8:50 AM 05/01/2018
Misc
Corrective Action Required
04/18/2018
-INSPECTION DENIED DUE TO LACK OF EROSION CONTROL AND MUD ON THE STREET. I CALLED AND LEFT THE MESSAGE WEEKS AGO ABOUT THE EROSION CONTROL AND MUD ON THE STREET. I ALSO POSTED THE EROSION CONTROL SIGNAGE ON THE SAME DAY. NOTHING WAS DONE SINCE.
Occupancy Inspection - Codes Residential Not Ready 5/2/2018 5/2/2018 05/02/2018
Misc
Corrective Action Required
05/01/2018
-INSPECTION DENIED DUE TO LACK OF EROSION CONTROL AND MUD ON THE STREET. I CALLED AND LEFT THE MESSAGE WEEKS AGO ABOUT THE EROSION CONTROL AND MUD ON THE STREET. I ALSO POSTED THE EROSION CONTROL SIGNAGE ON THE SAME DAY. NOTHING WAS DONE SINCE.
Sidewalk Inspection Partial 5/7/2018 at 10:40 AM 05/07/2018
PW-Misc
Informational
05/07/2018
Jeremy Young 05/07/2018 10:57 AM Contractor has the sidewalk ready to pour. They have an area that is currently right at ADA compliance. They also have a width tightening close to the driveway. I have marked the sidewalk and have contacted the contractor to have those fixed.
Erosion Control Inspection Residential Passed 05/09/2018
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/09/2018
EROSION CONTROL AND STREET CLEANUP REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 5/9/2018 5/9/2018 at 9:30 AM 05/09/2018
Misc
Corrective Action Required
05/02/2018
-SIDEWALK NOT APPROVED ON RECORD -REAR PORCH PIERS NOT INSPECTED BY CITY -INSTALL SUMP PUMP EXTENSION -SEAL EXTERIOR: ABOVE METER, AC DISCONNECT, GFCI, WALL PENETRATIONS, ETC -FIX DAMAGED SIDING NEAR GAS METER AREA -DRIVE GROUNDING ROD ALL THE WAY TO GROUND; THE GROUNDING CLAMP SHALL BE BELOW GRADE -INSTALL MAXIMUM 30 AMP BREAKER FOR THE AC UNIT
Occupancy Inspection - Codes Residential Full C of O 5/10/2018 5/10/2018 at 9:30 AM 05/10/2018
Misc
Resolved
05/10/2018
-SIDEWALK NOT APPROVED ON RECORD -REAR PORCH PIERS NOT INSPECTED BY CITY -INSTALL SUMP PUMP EXTENSION -SEAL EXTERIOR: ABOVE METER, AC DISCONNECT, GFCI, WALL PENETRATIONS, ETC -FIX DAMAGED SIDING NEAR GAS METER AREA -DRIVE GROUNDING ROD ALL THE WAY TO GROUND; THE GROUNDING CLAMP SHALL BE BELOW GRADE -INSTALL MAXIMUM 30 AMP BREAKER FOR THE AC UNIT
Sidewalk Inspection Failed 5/10/2018 5/11/2018 at 1:50 PM 05/11/2018
PW-Misc
Informational
05/07/2018
Jeremy Young 05/07/2018 10:57 AM Contractor has the sidewalk ready to pour. They have an area that is currently right at ADA compliance. They also have a width tightening close to the driveway. I have marked the sidewalk and have contacted the contractor to have those fixed.
PW-Misc
Informational
05/11/2018
Jeremy Young 05/11/2018 2:02 PM There are 4 panels that need to be replaced. There are gouges on each panel that have broken the top layer of the sidewalk.
Documents & Images
Date Uploaded File Type Document Name
09/25/2017 Receipt Receipt for transaction: 2017-006506
09/25/2017 Letter Codes Building Permit
09/26/2017 Plans DOC092617
09/27/2017 Letter Inspection Summary
10/13/2017 Letter Inspection Summary
10/16/2017 Letter Inspection Summary
10/16/2017 Letter Inspection Summary
12/11/2017 Letter Inspection Summary
12/13/2017 Letter Inspection Summary
12/18/2017 Letter Inspection Summary
04/18/2018 Letter Inspection Summary
05/01/2018 Letter Inspection Summary
05/07/2018 Letter DE-Daily Inspection Summary
05/09/2018 Letter Inspection Summary
05/10/2018 Letter Field Certificate of Occupancy
05/11/2018 Letter Codes Final Certificate of Occupancy
05/11/2018 Letter DE-Daily Inspection Summary
Upload Documents
  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:
Browse..





    Portal Home