Permit Application Status

PRRES20172630


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20172630
Building Permit - Residential
Certificate of Occupancy
PARK HOMES LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED PATIO FINISHED BASEMENT
07/31/2017
10/26/2017
06/10/2019
Locations
Contacts
PARK HOMES LLC, Address:644 NE LAKE POINTE DR  
PARK HOMES LLC, Address:4550 WARWICK BLVD APT 1204, Phone:(816) 564-2333  
BLUE VALLEY CONSTRUCTION GROUP, LLC, Address:P O BOX 241, Phone:(816) 867-5122  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
MCGRATH ELECTRIC, Address:601 E MAIN ST, Phone:(816) 726-3265  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/02/2017 08/22/2017
Nick Lightner
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $877.70 $877.70 Paid 10/26/2017
8331507-Sewer Connection Fee $360.00 $360.00 Paid 10/26/2017
Water Tap Fee $3,343.00 $3,343.00 Paid 10/26/2017
Water Meter Fee $431.83 $431.83 Paid 10/26/2017
Right of Way Permit Fee $75.00 $75.00 Paid 10/26/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 11/10/2017 (11:30) 11/10/2017 at 11:30 AM 11/10/2017
Misc
Corrective Action Required
11/10/2017
EROSION CONTROL NOT INSTALLED. INSPECTION DENIED
Footing Inspection - Residential Passed 11/10/2017 at 2:30 PM 11/10/2017
Misc
Resolved
11/10/2017
EROSION CONTROL NOT INSTALLED. INSPECTION DENIED
Underslab Plumbing Inspection - Residential Passed 12/5/2017 12/5/2017 at 10:40 AM 12/05/2017
Water Service Inspection - R Passed 1/10/2018 (2:30) 1/10/2018 at 2:30 PM 01/10/2018
Sewer Service Inspection - R Passed 1/10/2018 (2:30) 1/10/2018 at 2:35 PM 01/10/2018
Erosion Control Inspection Residential Failed 4/16/2018 04/16/2018
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/16/2018
EROSION CONTROL REQUIRED PER LS STANDARD. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Piers/Caissons Inspection - Residential Passed 4/6/2018 04/16/2018
Gas Service Inspection - Residential Passed 4/16/2018 4/16/2018 at 8:10 AM 04/16/2018
Erosion Control Inspection Residential Failed 4/26/2018 04/26/2018
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/16/2018
INSTALL EROSION AT REAR CORNER OF LOT NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Failed 4/26/2018 04/26/2018
Misc
Corrective Action Required
04/26/2018
-Locate and ground to ufer with#4 copper grounding electrode conductor -Ground service to water service line
All Rough Inspection - Residential Failed 4/26/2018 4/26/2018 at 9:25 AM 04/26/2018
Misc
Corrective Action Required
04/26/2018
FRAMING: -Plan on site. Check bearing wall at master bed area -Install the straps at inner side of garage portal brace walls. See plan -Anchor and protect garage steel column -Provide space for R15 insulation at garage wall return air -Brace all double 2x10 ceiling beam and LVL beam ends from rotation -Nail wall intersection at master bath shower -Flashing above window trim at rear -Double ceiling header joist above kitchen -Install flashing at stoop in such way that water not getting into the basement space below and concrete not in contact with wood -Fb fireplace space from roof. Use 3/4" sheathing or approved materials -Fb wall from furdown. Use 3/4” sheathing or other approved materials -Solidblock all joist ends above I beams -Toe nail joists to basement top and sill plates per code (3-8d) -Complete framing at basement shower and fb wall from ceiling as required -Solidblock cantilevered joists below master bed -Fb basement bedroom closet wall space from furdown space MECHANICAL: -Install fireplace and connect gas line -Dryer duct exceed length limit -Pan off return air space from ceiling furdown space above basement bedroom closet ELECTRICAL: -Protect wiring where secured within 1.25 of ceiling nailing surface. Look inside bed closet and near smoke alarm outside bedrooms -Receptacle at rear accessible from and reachable within 6.5 ft of grade PLUMBING: -Install loop vent per code -Vent roof flashing **DO NOT INSULATE
All Rough Inspection - Residential Failed 5/9/2018 5/9/2018 at 8:55 AM 05/09/2018
Misc
Corrective Action Required
04/26/2018
FRAMING: -Provide plan on site. Check bearing wall at master bed area -Provide space for R15 insulation at garage wall return air **You need to fur out the wall so the wall can be insulated -Frame around the garage steel column for 5/8" fire rock -Install flashing at stoop in such way that water not getting into the basement space below and concrete not in contact with wood -Fb wall from furdown. -Solidblock cantilevered joists below master bed **DONT FORGET TO INSULATE AND SEAL THE CANTILEVERED FLOOR -Fb basement bedroom closet wall space from furdown space MECHANICAL: -Install fireplace and connect gas line **Secure fireplace to framing -Pan off return air space from ceiling furdown space above basement bedroom closet ELECTRICAL: -Protect wiring where secured within 1.25 of ceiling nailing surface. Look inside bed closet and near smoke alarm outside bedrooms **Not done. You must protect the wiring **OK TO INSULATE
All Rough Inspection - Residential Failed 5/15/2018 at 1:25 PM 05/15/2018
Misc
Corrective Action Required
05/09/2018
FRAMING: -Provide plan on site. Check bearing wall at master bed area **take off roof load from walls not designated as bearing wall -Install flashing at stoop in such way that water not getting into the basement space below and concrete not in contact with wood -Solidblock cantilevered joists below master bed **DONT FORGET TO INSULATE AND SEAL THE CANTILEVERED FLOOR. YOU MUST INSULATE THE CANTILEVERED JOIST SPACE. PLEASE MECHANICAL: -Pan off return air space from ceiling furdown space above basement bedroom closet **go down to basement bedroom, then to closet, and look up. The return air space is opened to the ceiling space below. Pan underneath the joists to isolate the RA from ceiling space ELECTRICAL ADDENUM: -The guy who re-routed the dryer duct damaged the wiring. Two things must be done: rewire the circuit and make sure to reroute the wiring so that the wiring is not in contact with the hot dryer duct. **OK TO INSULATE
Electrical Service Inspection Passed 5/15/2018 at 2:00 PM 05/15/2018
Misc
Resolved
05/15/2018
-Locate and ground to ufer with#4 copper grounding electrode conductor -Ground service to water service line
All Rough Inspection - Residential Partial 5/21/2018 5/21/2018 at 9:30 AM 05/21/2018
Misc
Corrective Action Required
05/15/2018
FRAMING: -Install flashing at stoop in such way that water not getting into the basement space below and concrete not in contact with wood -Solidblock cantilevered joists below master bed **DONT FORGET TO INSULATE AND SEAL THE CANTILEVERED FLOOR. YOU MUST INSULATE THE CANTILEVERED JOIST SPACE. PLEASE **OK TO ROCK
Suspended Slab Inspection Passed 7/20/2018 (9:00) 7/20/2018 at 9:15 AM 07/20/2018
Driveway Inspection Partial 7/20/2018 7/20/2018 at 9:40 AM 07/20/2018
Informational
07/20/2018
The driveway is formed and has been compacted. Ready to pour.Steve Robbins 07/20/2018 10:00 AM
Sidewalk Inspection Partial 7/20/2018 7/20/2018 at 9:50 AM 07/20/2018
PW-Misc
Informational
07/20/2018
The sidewalk has been formed and rock has been compacted. ready to pour.Steve Robbins 07/20/2018 10:04 AM
Driveway Inspection Passed 7/24/2018 at 8:30 AM 07/24/2018
Informational
07/24/2018
The driveway has been poured and appears to meet all city standards.Steve Robbins 07/24/2018 9:13 AM
Sidewalk Inspection Passed 7/24/2018 at 8:40 AM 07/24/2018
PW-Misc
Informational
07/20/2018
The sidewalk has been formed and rock has been compacted. ready to pour.Steve Robbins 07/20/2018 10:04 AM
PW-Misc
Informational
07/24/2018
The sidewalk has been poured and appears to meet all city standards.Steve Robbins 07/24/2018 9:16 AM
Occupancy Inspection - Codes Residential Failed 4/3/2019 4/3/2019 at 10:10 AM 04/03/2019
Misc
Corrective Action Required
04/03/2019
THIS IS NOT READY FOR INSPECTION: MISSING PLUMBING, COOK TOP, DRYER OVERCURRENT, ETC
All Rough Inspection - Residential Passed 4/3/2019 04/25/2019
Misc
Resolved
04/25/2019
FRAMING: -Install flashing at stoop in such way that water not getting into the basement space below and concrete not in contact with wood -Solidblock cantilevered joists below master bed **DONT FORGET TO INSULATE AND SEAL THE CANTILEVERED FLOOR. YOU MUST INSULATE THE CANTILEVERED JOIST SPACE. PLEASE **OK TO ROCK
Occupancy Inspection - Codes Residential Failed 4/25/2019 4/25/2019 at 9:50 AM 04/25/2019
Misc
Corrective Action Required
04/03/2019
-Final grade, sod, splash blocks -Notch deck posts and install deck beam to posts -Fix ground fault condition of rear gfci receptacle -Seal exterior wall penetrations -Secure AC whip -Install tamper proof caps at AC coolant valve -Install front light. Light fixture shall meet security code -Install CO&smoke alarm outside front bedroom -Connect gas supply to cooktop -Receptacle right side of cooktop-support receptacle yoke and provide gfci protection -Install security strike plate at deck door screwed to studs with 3” screws -Support receptacle yokes at wet bar countertop -Install breaker lock for oven, out-of-sight water heater
Occupancy Inspection - Codes Residential Failed 4/29/2019 4/29/2019 at 9:30 AM 04/29/2019
Misc
Corrective Action Required
04/25/2019
**INSTALL SILT FENCE PER CITY REQUIREMENT, ESPECIALLY ALONG PROPERTY LINE -Final grade, sod, splash blocks -Notch deck posts and install deck beam to posts -Seal exterior wall penetrations -Install security strike plate at deck door screwed to studs with 3” screws
Occupancy Inspection - Codes Residential Failed 4/30/2019 4/30/2019 at 9:10 AM 04/30/2019
Misc
Corrective Action Required
04/29/2019
**INSTALL SILT FENCE PER CITY REQUIREMENT, ESPECIALLY ALONG PROPERTY LINE -Sod, splash blocks
Erosion Control Inspection Residential Passed 06/10/2019
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/25/2019
INSTALL EROSION AT REAR CORNER OF LOT NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Full C of O 6/10/2019 at 10:25 AM 06/10/2019
Misc
Resolved
06/10/2019
**INSTALL SILT FENCE PER CITY REQUIREMENT, ESPECIALLY ALONG PROPERTY LINE -Sod, splash blocks
Documents & Images
Date Uploaded File Type Document Name
08/22/2017 Letter Codes Residential Plan Review
08/25/2017 Letter Codes Residential Plan Review
10/26/2017 Receipt Receipt for transaction: 2017-006997
10/26/2017 Letter Codes Building Permit
10/30/2017 Plot Plan DOC103017-012
11/10/2017 Letter Inspection Summary
11/10/2017 Letter Inspection Summary
12/05/2017 Letter Inspection Summary
01/10/2018 Letter Inspection Summary
04/06/2018 Letter Inspection Summary
04/16/2018 Letter Inspection Summary
04/26/2018 Letter Inspection Summary
05/09/2018 Letter Inspection Summary
05/15/2018 Letter Inspection Summary
05/21/2018 Letter Inspection Summary
07/20/2018 Letter Inspection Summary
07/20/2018 Letter DE-Daily Inspection Summary
07/20/2018 Letter DE-Daily Inspection Summary
07/24/2018 Letter DE-Daily Inspection Summary
07/24/2018 Letter DE-Daily Inspection Summary
04/03/2019 Letter INSPECTION SUMMARY
04/25/2019 Letter INSPECTION SUMMARY
04/25/2019 Letter INSPECTION SUMMARY
04/29/2019 Letter INSPECTION SUMMARY
04/30/2019 Letter INSPECTION SUMMARY
06/10/2019 Letter Codes Final Certificate of Occupancy
06/10/2019 Letter Field Certificate of Occupancy
06/10/2019 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home