Permit Application Status

PRRES20171814


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20171814
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT
06/02/2017
06/09/2017
12/03/2017
06/21/2018
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:1248 SW WYSTERIA DR  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/09/2017 06/07/2017
Jonathon Hilton
Residential Plan Review Approved 06/09/2017 06/07/2017
Jonathon Hilton
Plot Plan Review Approved 06/06/2017 06/07/2017
Nick Lightner
Basement opening elevations
Resolved
06/07/2017

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. *Please provide the MBOE on the plot plan.
Spot elevations
Resolved
06/07/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *Please double check the drainage on the SW corner of the house.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,056.53 $1,056.53 Paid 06/09/2017
8331507-Sewer Connection Fee $540.00 $540.00 Paid 06/09/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 06/09/2017
Water Meter Fee $405.36 $405.36 Paid 06/09/2017
Right of Way Permit Fee $75.00 $75.00 Paid 06/09/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/13/2017 6/13/2017 06/13/2017
Underslab Plumbing Inspection - Residential Passed 6/29/2017 6/29/2017 06/28/2017
Electrical Service Inspection Passed 8/23/2017 8/23/2017 08/23/2017
Gas Service Inspection - Residential Passed 8/23/2017 8/23/2017 08/23/2017
All Rough Inspection - Residential Failed 8/23/2017 8/23/2017 08/23/2017
Misc
Corrective Action Required
08/23/2017
FRAMING: -NAIL THE GARAGE PORTAL FRAME WALL SHEATHING TO SILL PLATE 3" OC -ANCHOR ALL SILL PLATES WITHIN 12" OF BREAKS IN GARAGE AND BASEMENT -NAIL HANGERS ABOVE MASTER SHOWER; NAIL THE HANGER AT LVL-LVL CONNECTION ABOVE KITCHEN -MASTER BED EXTERIOR DOOR-FILL IN GAP WITH SOLID WOOD AT STRIKE PLATE SIDE PER LS SECURITY CODE -BRACE TRIPLE LVL BEAM END FROM ROTATION -INSTALL TWO STUD SUPPORT AND NAIL TOGETHER. MASTER SHOWER/HALLWAY AT ANGLED WALL CORNER -SUPPORT BOTTOM OF THE VALLEY RAFTER AT KITCHEN CORNER -NAIL CORNER STUDS AT FRONT BED -THE A-FRAME ABOVE FROM BED-COMPLETELY FILL IN GAP BETWEEN THE RAFTERS AND THE RIDGE -AT FRONT BEDROOM, LAND THE SUPPORT STRUT FOR THE RIDGE TO THE BEARING WALL (REAR CLOSET WALL) -BASEMENT EXTERIOR DOOR-FILL IN GAP WITH SOLID WOOD AT STRIKE PLATE SIDE AND HINGES PER LS SECURITY CODE -FIREBLOCK THE NORTH BASEMENT BATH WALL FROM CEILING FURDOWN SPACE; FB SPACE AT SOUTH BATH TUB ELECTRICAL: -COMPLETE ELECTRICAL IN MASTER CLOSET MECHANICAL: -PAN OFF THE ELECTRICAL WIRING FROM THE RETURN AIR SPACE AT TRIANGULAR SPACE ADJACENT TO MASTER BATH SINK ***OK TO INSULATE
All Rough Inspection - Residential Failed 8/28/2017 8/28/2017 08/28/2017
Misc
Corrective Action Required
08/23/2017
-ANCHOR ALL SILL PLATES WITHIN 12" OF BREAKS IN BASEMENT **AT EXTERIOR DOOR
Sewer Service Inspection - R Partial 8/30/2017 (4:00) 8/30/2017 08/30/2017
Misc
Corrective Action Required
08/30/2017
-CONNECT SEWER TRACER WIRE WITH SPLIT BOLT AND RUN TO HOUSE
Water Service Inspection - R Partial 8/29/2017 (4:00) 8/30/2017 08/30/2017
Water Service Inspection - R Passed 8/31/2017 08/31/2017
Sewer Service Inspection - R Passed 8/30/2017 (4:00) 8/31/2017 08/31/2017
Misc
Resolved
08/31/2017
-CONNECT SEWER TRACER WIRE WITH SPLIT BOLT AND RUN TO HOUSE
Piers/Caissons Inspection - Residential Passed 9/5/2017 9/5/2017 09/05/2017
Driveway Inspection Passed 9/21/2017 9/21/2017 at 10:00 AM 09/21/2017
Sidewalk Inspection Passed 9/21/2017 9/21/2017 at 10:00 AM 09/21/2017
Erosion Control Inspection Residential Failed 9/21/2017 at 10:00 AM 09/21/2017
Corrective Action Required
09/21/2017
ESC device(s) needed on NE corner of the property.
All Rough Inspection - Residential Passed 11/10/2017
Misc
Resolved
11/10/2017
-ANCHOR ALL SILL PLATES WITHIN 12" OF BREAKS IN BASEMENT **AT EXTERIOR DOOR
Occupancy Inspection - Codes Residential Failed 11/10/2017 11/10/2017 at 1:15 PM 11/10/2017
Misc
Corrective Action Required
11/10/2017
-OBTAIN LAWN IRRIGATION PERMIT. SUBMIT THE BACKFLOW VALVE TEST REPORT TO CITY -SEAL EXTERIOR WALL PENETRATIONS -INSTALL SPLASHBLOCKS FOR DOWNSPOUTS AT REAR AND AT SUMP PUMP DISCHARGE -GFCI RECEPTACLE NEAR AC HAS HOT/NEUTRAL REVERSED. -INSTALL PROPER OUTDOOR-RATED FASTERNERS FOR DECK HANGERS. SOME HANGER MISSING NAILS -INSTALL OUTDOOR RECEPTACLE AT SIDE OF 3RD CAR GARAGE OR TERMINATE AND CAP -COMPLETE GAS HOOK-UP AND PROTECT GAS CONNECTOR TO COOKTOP -RECEPTACLE IN LAUNDRY RM WITHIN 6 FT OF SINK MUST BE GFCI-PROTECTED -PENDANT LIGHT FIXTURE NOT ALLOWED WITHIN A BATH TUB ZONE. DEF: ZONE 8 FT ABOVE FLOOD RIM AND 3 FT OUT FROM INNER WALL OF TUB
Occupancy Inspection - Codes Residential Temporary C of O 11/14/2017 11/14/2017 at 9:45 AM 11/14/2017
Misc
Corrective Action Required
11/10/2017
-OBTAIN LAWN IRRIGATION PERMIT. SUBMIT THE BACKFLOW VALVE TEST REPORT TO CITY -INSTALL SEWER TRACER BOX
Occupancy Inspection - Codes Residential Full C of O 6/21/2018 at 9:15 AM 06/21/2018
Misc
Resolved
06/21/2018
-INSTALL SEWER TRACER BOX
Documents & Images
Date Uploaded File Type Document Name
06/06/2017 Letter Codes Residential Plan Review
06/09/2017 Receipt Receipt for transaction: 2017-003679
06/09/2017 Letter Codes Building Permit
06/12/2017 Plot Plan DOC061217-009
06/13/2017 Letter Inspection Summary
06/28/2017 Letter Inspection Summary
08/23/2017 Letter Inspection Summary
08/28/2017 Letter Inspection Summary
08/30/2017 Letter Inspection Summary
08/31/2017 Letter Inspection Summary
09/05/2017 Letter Inspection Summary
09/21/2017 Letter Inspection Summary
11/10/2017 Letter Inspection Summary
11/14/2017 Letter Codes Temporary Certificate of Occupancy
12/21/2017 Letter Codes 10 Day Letter
06/21/2018 Letter Field Certificate of Occupancy
06/22/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home