Permit Application Status

PRRES20170922


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20170922
Building Permit - Residential
Certificate of Occupancy
PFEIFER HOMES INC
NEW SINGLE FAMILY
NEW HOUSE FINISHED BASEMENT COVERED DECK ** REINSPECTION FEE PAID
03/29/2017
04/04/2017
03/08/2018
Locations
Contacts
PFEIFER HOMES INC, Address:1550 SW MARKET ST  
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210, Phone:(816) 524-5245  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 03/31/2017 03/30/2017
Shannon McGuire
Plot Plan Review Approved 03/31/2017 03/30/2017
Nick Lightner
Residential Plan Review Approved 03/31/2017 03/30/2017
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $885.52 $885.52 Paid 04/04/2017
8331507-Sewer Connection Fee $480.00 $480.00 Paid 04/04/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 04/04/2017
Water Meter Fee $405.36 $405.36 Paid 04/04/2017
Right of Way Permit Fee $75.00 $75.00 Paid 04/04/2017
Additional Permit Fee $30.00 $30.00 Paid 09/13/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/9/2017 (10:30) 5/9/2017 05/09/2017
Underslab Plumbing Inspection - Residential Passed 5/30/2017 5/30/2017 05/30/2017
Water Service Inspection - R Partial 6/2/2017 (8:45) 6/2/2017 06/02/2017
Sewer Service Inspection - R Passed 6/2/2017 (8:45) 6/2/2017 06/02/2017
Water Service Inspection - R Passed 6/2/2017 6/2/2017 06/02/2017
Electrical Service Inspection Passed 8/25/2017 8/25/2017 08/25/2017
Gas Service Inspection - Residential Passed 8/25/2017 8/25/2017 08/25/2017
Erosion Control Inspection Residential Partial 8/25/2017 08/25/2017
Misc
Corrective Action Required
08/25/2017
8/25-EROSION CONTROL IN COMPLIANCE
All Rough Inspection - Residential Failed 8/25/2017 8/25/2017 08/25/2017
Misc
Corrective Action Required
08/25/2017
FRAMING: -MOVE THE ROOF SUPPORT TO FRONT CLOSET BEARING WALL OF STUDY RM -FIREBLOCKING: FB FIREPLACE WALL FROM ROOF; FB BASEMENT BATH CLOSET WALL FROM FURDOWN SPACE; FB BATH SINK WALL FROM FURDOWN SPACE -SUPPORT TOP OF HIPS ABOVE MASTER BATH AND ABOVE KITCHEN -PROVIDE MIN. 6 FT 8 INCHES HEADROOM CLEARANCE ABOVE STAIR, MEASURED VERTICALLY FROM TREAD NOSE-NOSE PLANE -ANCHOR BASEMENT SILL PLATES WITHIN 12" OF BREAKS, INCLUDING NEAR DOORS -SOLIDBLOCK JOISTS BELOW MASTER BED BEARING WALL PER PLAN -INSTALL SINGLE LVL ABOVE STORAGE RM PER PLAN -SOLIDBLOCK UNDER LVL POINT LOAD NEAR KITCHEN RANGE -BASEMENT EXTERIOR DOOR: BLOCK PER SECURITY; FILL IN GAPS BEHIND HINGES AND AT STRIKE PLATE SIDE PER LS SECURITY CODE ELECTRICAL: -BOND HYDROTUB MOTOR -MOVE THE MASTER BED SMOKE MIN. 3 FT FROM FAN -SECURE SE CABLE WITHIN 12" OF PANEL MECHANICAL: -SEAL GAP ALONG RETURN AIR DOUBLE STUDS WALL BETWEEN MASTER BED AND FIREPLACE -VENT MUD BATH BATHFAN TO OUTSIDE -EXTEND DUCT TO CEILING LEVEL AT BASEMENT HALL BATH ***OK TO INSULATE
All Rough Inspection - Residential Failed 9/1/2017 9/1/2017 08/31/2017
Misc
Corrective Action Required
08/25/2017
-FIREBLOCKING: FB BASEMENT BATH CLOSET WALL FROM FURDOWN SPACE; FB BATH SINK WALL FROM FURDOWN SPACE -SUPPORT TOP OF HIPS ABOVE MASTER BATH **ADD A BLOCK TO CATCH THE TOP OF THE HIP -PROVIDE MIN. 6 FT 8 INCHES HEADROOM CLEARANCE ABOVE STAIR, MEASURED VERTICALLY FROM TREAD NOSE-NOSE PLANE **INSTALL THE SINGLE PLY LVL HEADER TO CARRY THE END LOAD OF THE JOISTS. THE LVL HEADER CAN BE OFFSET INWARD SO THE CEILING CAN BE BEVELED. -ANCHOR BASEMENT SILL PLATES WITHIN 12" OF BREAKS, INCLUDING NEAR DOORS **NOT DONE AT ALL -INSTALL SINGLE LVL ABOVE STORAGE RM PER PLAN -BASEMENT EXTERIOR DOOR: FILL IN GAPS BEHIND HINGES AND AT STRIKE PLATE SIDE PER LS SECURITY CODE **FILL IN WITH WOOD, NOT FOAM ***OK TO INSULATE
All Rough Inspection - Residential Failed 9/5/2017 9/5/2017 at 9:10 AM 09/05/2017
Misc
Corrective Action Required
08/31/2017
-SUPPORT TOP OF HIPS ABOVE MASTER BATH **ADD A BLOCK TO CATCH THE TOP OF THE HIP -PROVIDE MIN. 6 FT 8 INCHES HEADROOM CLEARANCE ABOVE STAIR, MEASURED VERTICALLY FROM TREAD NOSE-NOSE PLANE **INSTALL THE SINGLE PLY LVL HEADER TO CARRY THE END LOAD OF THE JOISTS. THE LVL HEADER CAN BE OFFSET INWARD SO THE CEILING CAN BE BEVELED. -ANCHOR BASEMENT SILL PLATES WITHIN 12" OF BREAKS, INCLUDING NEAR DOORS **RE-ANCHOR SILL PLATE AT DOOR, NEAR THE OUT-OF-PLATE ANCHOR -BASEMENT EXTERIOR DOOR: FILL IN GAPS BEHIND HINGES AND AT STRIKE PLATE SIDE PER LS SECURITY CODE **FILL IN WITH WOOD, NOT FOAM ***OK TO INSULATE
All Rough Inspection - Residential Failed 9/11/2017 9/11/2017 09/11/2017
Misc
Corrective Action Required
09/05/2017
-SUPPORT TOP OF HIPS ABOVE MASTER BATH **ADD A BLOCK TO CATCH THE TOP OF THE HIP -PROVIDE MIN. 6 FT 8 INCHES HEADROOM CLEARANCE ABOVE STAIR, MEASURED VERTICALLY FROM TREAD NOSE-NOSE PLANE **INSTALL THE SINGLE PLY LVL HEADER TO CARRY THE END LOAD OF THE JOISTS. THE LVL HEADER CAN BE OFFSET INWARD SO THE CEILING CAN BE BEVELED. **REFER BACK TO THE ENGINEER PLAN OR THE ENGINEER MUST INSPECT AND APPROVED THE FRAMING -ANCHOR BASEMENT SILL PLATES WITHIN 12" OF BREAKS, INCLUDING NEAR DOORS **RE-ANCHOR SILL PLATE AT DOOR, NEAR THE OUT-OF-PLATE ANCHOR **DRILLED HOLE BUT ANCHOR NOT INSTALLED -BASEMENT EXTERIOR DOOR: FILL IN GAPS AT STRIKE PLATE SIDE PER LS SECURITY CODE **FILL IN WITH WOOD, NOT FOAM **AT THE STRIKE PLATE SIDE, FILL IN GAP BETWEEN DOOR FRAME AND STUD (WITH SOLIDWOOD) FROM 12" ABOVE TO 12" BELOW THE STRIKE PLATE ***OK TO INSULATE **11-SEPT-REINSPECTION FEE ASSESSED. A REINSPECTION SHALL BE ASSESSED FROM EVERY SUBSEQUENT FAILED ALLROUGH INSPECTION
All Rough Inspection - Residential Passed 9/13/2017 9/13/2017 09/13/2017
Misc
Resolved
09/13/2017
-SUPPORT TOP OF HIPS ABOVE MASTER BATH **ADD A BLOCK TO CATCH THE TOP OF THE HIP -PROVIDE MIN. 6 FT 8 INCHES HEADROOM CLEARANCE ABOVE STAIR, MEASURED VERTICALLY FROM TREAD NOSE-NOSE PLANE **INSTALL THE SINGLE PLY LVL HEADER TO CARRY THE END LOAD OF THE JOISTS. THE LVL HEADER CAN BE OFFSET INWARD SO THE CEILING CAN BE BEVELED. **REFER BACK TO THE ENGINEER PLAN OR THE ENGINEER MUST INSPECT AND APPROVED THE FRAMING -ANCHOR BASEMENT SILL PLATES WITHIN 12" OF BREAKS, INCLUDING NEAR DOORS **RE-ANCHOR SILL PLATE AT DOOR, NEAR THE OUT-OF-PLATE ANCHOR **DRILLED HOLE BUT ANCHOR NOT INSTALLED -BASEMENT EXTERIOR DOOR: FILL IN GAPS AT STRIKE PLATE SIDE PER LS SECURITY CODE **FILL IN WITH WOOD, NOT FOAM **AT THE STRIKE PLATE SIDE, FILL IN GAP BETWEEN DOOR FRAME AND STUD (WITH SOLIDWOOD) FROM 12" ABOVE TO 12" BELOW THE STRIKE PLATE ***OK TO INSULATE **11-SEPT-REINSPECTION FEE ASSESSED. A REINSPECTION SHALL BE ASSESSED FROM EVERY SUBSEQUENT FAILED ALLROUGH INSPECTION
Driveway Inspection Passed 9/20/2017 9/20/2017 at 12:15 PM 09/20/2017
Occupancy Inspection - Codes Residential Failed 2/6/2018 2/6/2018 02/06/2018
Misc
Corrective Action Required
09/11/2017
-HANDRAILS BASEMENT AND GARAGE ARE REQUIRED TO TERMINATE AT THE NOSING OF THE BOTTOM TREAD. -GARAGE CANTILEVER, INSTALL 5/8THS GYP ON THE UNDERSIDE.
Occupancy Inspection - Codes Residential Full C of O 3/8/2018 3/8/2018 at 8:20 AM 03/08/2018
Misc
Resolved
03/08/2018
-HANDRAILS BASEMENT AND GARAGE ARE REQUIRED TO TERMINATE AT THE NOSING OF THE BOTTOM TREAD. -GARAGE CANTILEVER, INSTALL 5/8THS GYP ON THE UNDERSIDE.
Documents & Images
Date Uploaded File Type Document Name
04/04/2017 Receipt Receipt for transaction: 2017-001216
04/04/2017 Letter Codes Building Permit
05/09/2017 Letter Inspection Summary
05/30/2017 Letter Inspection Summary
06/02/2017 Letter Inspection Summary
06/02/2017 Letter Inspection Summary
08/25/2017 Letter Inspection Summary
08/31/2017 Letter Inspection Summary
09/05/2017 Letter Inspection Summary
09/11/2017 Letter Re-Inspection Fee
09/11/2017 Letter Inspection Summary
09/12/2017 Engineer Report/Study DOC091217-012
09/13/2017 Receipt Receipt for transaction: 2017-006330
09/13/2017 Letter Inspection Summary
09/13/2017 Engineer Report/Study 1324 NE BRANDYWINE DR
09/20/2017 Letter Inspection Summary
02/06/2018 Letter Inspection Summary
03/08/2018 Letter Field Certificate of Occupancy
03/14/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home