Summary
PRRES20170806
Building Permit - Residential
Certificate of Occupancy
NICK ZVACEK CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT
03/22/2017
05/05/2017
09/20/2018
Locations
Contacts
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR  
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Rejected 03/24/2017 04/26/2017
Nick Lightner
Residential Plan Review Approved 03/24/2017 03/22/2017
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $965.46 $965.46 Paid 05/05/2017
8331504-EFHB Middle Big Creek, Full $535.68 $535.68 Paid 05/05/2017
8331507-Sewer Connection Fee $480.00 $480.00 Paid 05/05/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 05/05/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 05/05/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 05/05/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/11/2017 (4:00) 5/11/2017 05/11/2017
Underslab Plumbing Inspection - Residential Failed 6/8/2017 6/8/2017 06/08/2017
Misc
Corrective Action Required
06/08/2017
UNDERSLAB DRAINAGE INCOMPLETE
Underslab Plumbing Inspection - Residential Passed 6/9/2017 6/9/2017 06/09/2017
Misc
Resolved
06/09/2017
UNDERSLAB DRAINAGE INCOMPLETE
Erosion Control Inspection Residential Failed 8/24/2017 at 10:40 AM 08/24/2017
All Rough Inspection - Residential Not Ready 8/24/2017 8/24/2017 at 10:50 AM 08/24/2017
Misc
Corrective Action Required
08/24/2017
NO INSPECTION - EROSION CONTROL
Piers/Caissons Inspection - Residential Passed 8/29/2017 (8:00) 8/29/2017 at 8:30 AM 08/29/2017
Electrical Service Inspection Passed 8/24/2017 8/29/2017 at 8:35 AM 08/29/2017
Gas Service Inspection - Residential Passed 8/24/2017 8/29/2017 at 8:40 AM 08/29/2017
Gas Piping Inspection - Residential Passed 8/29/2017 at 8:45 AM 08/29/2017
Erosion Control Inspection Residential Partial 8/29/2017 at 8:50 AM 08/29/2017
All Rough Inspection - Residential Failed 8/29/2017 at 8:55 AM 08/29/2017
Misc
Corrective Action Required
08/24/2017
BSMT: Firestop furrouts and penetrations. BSMT: Blocking at cantelever. BSMT: Finish plumbing installation. BSMT: Anchor columns. BSMT: Floot joists bored within 2" of bottom (near elec panel). 1st FLR: Firestop top of duct chase. 1st FLR: Corner nailing. 1st FLR: >2 consecutive studs bored for DWV in Master Bath. 1st FLR: Vent bath fan. 1st FLR: Firestop at ceiling line of Great Room. GARAGE: Need 4 studs under steel beam. GARAGE: Need attic access. 2nd FLR: Ridge is supported on a non-load-bearing wall. 2nd FLR: Snow blocking at South wall. ALL: Missing purlins. ALL: Elec. nail guards. ALL: Protect NM within 6' attic access. ALL: Top-plate straps where bored for DWV should be nailed (not fastened with drywall screws).
All Rough Inspection - Residential Failed 9/1/2017 9/1/2017 at 12:00 PM 09/01/2017
Misc
Corrective Action Required
08/29/2017
1. BSMT: Firestop furrouts and penetrations. 2. BSMT: Blocking at cantelever. 3. BSMT: Finish plumbing installation. *Firestop top of deadspace behind shower. 4. BSMT: Anchor columns. 5. BSMT: Floor joists bored within 2" of bottom (near elec panel). 6. 1st FLR: Firestop top of duct chase. 7. 1st FLR: Corner nailing. 8. 1st FLR: >2 consecutive studs bored for DWV in Master Bath. 9. GARAGE: Need attic access. *Finish framing. 10. 2nd FLR: Ridge is supported on a non-load-bearing wall. 11. ALL: Missing purlins. *Newly installed purlins are not long enough, are not adequately supported, and the purlin legs that are in place bear on non-load-bearing walls. 12. ALL: Elec. nail guards. 13. ALL: Protect NM within 6' attic access. 14. ALL: Top-plate straps where bored for DWV should be nailed (not fastened with drywall screws).
All Rough Inspection - Residential Failed 9/7/2017 at 9:35 AM 09/07/2017
Misc
Corrective Action Required
09/01/2017
1. BSMT: Firestop furrouts and penetrations. 3. BSMT: Finish plumbing installation. *Firestop top of deadspace behind shower. 5. BSMT: Floor joists bored within 2" of bottom (near elec panel). 6. 1st FLR: Firestop top of duct chase. 7. 1st FLR: Corner nailing. 9. GARAGE: Need attic access. *Finish framing. **Need joist hangers. 10. 2nd FLR: Ridge is supported on a non-load-bearing wall. *Builder is working with Architect to get revised plans (re: Item #s 10 & 11). 11. ALL: Missing purlins. *Newly installed purlins are not long enough, are not adequately supported, and the purlin legs that are in place bear on non-load-bearing walls. 12. ALL: Elec. nail guards. 13. 2nd FLR: Protect NM within 6' attic access. 14. ALL: Top-plate straps where bored for DWV should be nailed (not fastened with drywall screws).
All Rough Inspection - Residential Failed 9/26/2017 at 9:15 AM 09/26/2017
Misc
Corrective Action Required
09/07/2017
1. BSMT: Firestop furrouts and penetrations. 3. BSMT: Firestop top of deadspace behind shower. 6. 1st FLR: Firestop top of duct chase. 9. GARAGE: Need attic access. *Finish framing. **Need joist hangers. 10. 2nd FLR: Ridge is supported on a non-load-bearing wall. *The Engineer's recommended repairs have not been completed. 12. ALL: Elec. nail guards. 13. 2nd FLR: Protect NM within 6' attic access. 14. ALL: Top-plate straps where bored for DWV should be nailed (not fastened with drywall screws).
All Rough Inspection - Residential Failed 9/29/2017 9/29/2017 at 3:45 AM 09/29/2017
Misc
Corrective Action Required
09/26/2017
10. 2nd FLR: Ridge is supported on a non-load-bearing wall. *The Engineer's recommended repairs have not been completed. **Move/Install struts as discussed on 9/29.
All Rough Inspection - Residential Passed 10/2/2017 at 1:25 AM 10/02/2017
Misc
Resolved
10/02/2017
10. 2nd FLR: Ridge is supported on a non-load-bearing wall. *The Engineer's recommended repairs have not been completed. **Move/Install struts as discussed on 9/29.
Sewer Service Inspection - R Passed 10/11/2017 (10:45) 10/11/2017 at 11:10 AM 10/11/2017
Water Service Inspection - R Partial 10/11/2017 at 11:15 AM 10/11/2017
Water Service Inspection - R Passed 10/12/2017 (8:45) 10/12/2017 at 10:25 AM 10/12/2017
Driveway Inspection Passed 10/13/2017 10/23/2017 at 9:35 AM 10/23/2017
Informational
10/23/2017
Tom Chandler 10/23/2017 9:38 AM Driveway has been completed and passed final inspection.
Plot Plan Inspection Passed 4/4/2018 at 1:40 PM 04/04/2018
Occupancy Inspection - Codes Residential Failed 4/10/2018 4/10/2018 04/10/2018
R313 SMOKE ALARMS
Corrective Action Required
04/10/2018
- CONNECT BSMT BATH VENT. BACK UNFINIHSED AREA. -LABEL SMOKES. - LAWN SPRINKLER PERMIT. -HAMMER ARESTOR -BSMT BEDROOM HAS NO EGRESS CANNOT BE USED AS BEDROOM WITH A CLOTHES CLOSET. -ROCK UNDER BSMT STAIRS -SELF CLOSING GARAGAE DOOR HINGE
Occupancy Inspection - Codes Residential Failed 9/11/2018 9/11/2018 at 9:30 AM 09/11/2018
R313 SMOKE ALARMS
Resolved
09/11/2018
- CONNECT BSMT BATH VENT. BACK UNFINIHSED AREA. -LABEL SMOKES. - LAWN SPRINKLER PERMIT. -HAMMER ARESTOR -BSMT BEDROOM HAS NO EGRESS CANNOT BE USED AS BEDROOM WITH A CLOTHES CLOSET. -ROCK UNDER BSMT STAIRS -SELF CLOSING GARAGAE DOOR HINGE
R313 SMOKE ALARMS
Corrective Action Required
09/11/2018
* Label smoke alarms*
Occupancy Inspection - Codes Residential Full C of O 9/20/2018 9/20/2018 09/20/2018
R313 SMOKE ALARMS
Resolved
09/20/2018
* Label smoke alarms*
Documents & Images
Date Uploaded File Type Document Name
05/05/2017 Receipt Receipt for transaction: 2017-001864
05/05/2017 Letter Codes Building Permit
05/09/2017 Plot Plan DOC050917-009
05/11/2017 Letter Inspection Summary
06/08/2017 Letter Inspection Summary
06/09/2017 Letter Inspection Summary
08/24/2017 Letter Inspection Summary
08/29/2017 Letter Inspection Summary
09/01/2017 Letter Inspection Summary
09/07/2017 Letter Inspection Summary
09/25/2017 Letter Framing Review Comments
09/26/2017 Letter Inspection Summary
09/29/2017 Letter Inspection Summary
10/02/2017 Letter Inspection Summary
10/11/2017 Letter Inspection Summary
10/12/2017 Letter Inspection Summary
10/23/2017 Letter DE-Daily Inspection Summary
04/10/2018 Letter Inspection Summary
04/10/2018 Letter Inspection Summary
08/28/2018 Letter Codes 140 Day Letter
09/11/2018 Letter Inspection Summary
09/20/2018 Letter Field Certificate of Occupancy
09/21/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home