Permit Application Status

PRRES20163192


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20163192
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY HOME COVERED DECK
12/14/2016
01/12/2017
06/13/2018
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 219119  
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 12/16/2016 12/19/2016
Jennifer Thompson
Residential Plan Review Approved 12/16/2016 12/16/2016
Jonathon Hilton
Plot Plan Review Approved 12/16/2016
Kim Brennan
Plot Plan Review Rejected 12/16/2016 12/15/2016
Jonathon Smith
Plot Plan Review (P&D) Rejected 12/16/2016 12/14/2016
Jennifer Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,027.07 $1,027.07 Paid 01/12/2017
8331507-Sewer Connection Fee $540.00 $540.00 Paid 01/12/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 01/12/2017
Water Meter Fee $405.36 $405.36 Paid 01/12/2017
Right of Way Permit Fee $75.00 $75.00 Paid 01/12/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/20/2017 (8:15) 1/20/2017 01/20/2017
Underslab Plumbing Inspection - Residential Passed 2/8/2017 2/8/2017 02/08/2017
Sewer Service Inspection - R Passed 2/15/2017 02/17/2017
Water Service Inspection - R Partial 2/17/2017 (8:00) 2/17/2017 02/17/2017
Water Service Inspection - R Passed 2/17/2017 (2:00) 2/17/2017 02/17/2017
Piers/Caissons Inspection - Residential Passed 4/10/2017 (8:00) 4/10/2017 04/10/2017
Electrical Service Inspection Passed 5/9/2017 5/9/2017 05/09/2017
Gas Service Inspection - Residential Failed 5/9/2017 5/9/2017 05/09/2017
Misc
Corrective Action Required
05/09/2017
-NO PRESSURE
All Rough Inspection - Residential Failed 5/9/2017 5/9/2017 05/09/2017
Misc
Corrective Action Required
05/09/2017
FRAMING: -PROVIDE FULL CITY APPROVED PLAN ON SITE, INCLUDING ANY REVISION (SUN ROOM) -NAIL ALL EXTERIOR SIDING PER CODE -UNCOVER THE FLOOR FRAMING OF THE SUN ROOM -GARAGE PORTAL BRACE WALLS: COMPLETE INSTALL SHEATHING TO THE REST OF THE WALL; SEAMS MUST BE WITHIN 24" OF MID-WALL HEIGHT AND MUST BE BLOCKED AND NAILED; NAIL SHEATHING 3" OC -PROVIDE ATTIC ACCESS TO ROOF SPACE ABOVE GARAGE -COMPLETE GARAGE SOFFIT AND FIREBLOCK AS REQUIRED -ABOVE GARAGE, FIX THE OVERNOTCHED JOIST AT SHOWER TRAP BY HEADER OFF TO ADJACENT JOIST. THE HEADER JOIST MUST BE WITHIN 3 FT OF I BEAM SUPPORT, OR THE TRIMMER JOISTS MUST BE DOUBLED UP -BLOCK LAPPED JOISTS ABOVE GARAGE I BEAM -SUPPORT JOIST AT MUD RM/GARAGE WALL RETURN AIR SPACE -AT GARAGE WALL&CEILING RETURN AIR SPACE, PROVIDE R-15 THERMAL ENVELOP AT WALL AND R-19 AT CEILING -FIREBLOCK DUCT CHASE FROM JOIST SPACE -HEADER OFF THE JOIST AT DUCT CHASE -NAIL DOUBLE HANGER NEAR SUN RM INTERIOR DOOR -COMPLETE INSTALLING SUN RM EXTERIOR DOOR; INSTALL SECURITY BLOCKING; FILL IN ANY EXCESSIVE GAP AT HINGES AND STRIKE PLATE SIDE PER SECURITY CODE -INSULATION USED AS FIREBLOCKING MATERIAL MUST BE STAPLED IN PLACE -HAVE THE ENGINEER ADDRESS THE FULL SUPPORT FOR THE I BEAM THAT SPANS FROM EAST SIDE OF HOUSE TO CORNER OF DUCT CHASE -INSTALL HANGER FOR THE TRIPLE JOIST CONNECTION TO I BEAM -ABOVE FRONT DINING AREA, INSTALL DOUBLE CEILING JOIST UNDER POINT LOAD OF THE ROOF SUPPORT BEAM ABOVE FRONT BED -BRACE INTERIOR WALLS PER PLAN -AT MID-STAIR LANDING, SUPPORT WALL BOTTOM PLATE TO SILL -PROVIDE MIN. 6 FT 8 INCHES HEADROOM CLEARANCE ABOVE STAIR PER CODE -INSTALL DOUBLE JOIST UNDER WALL LINE OF FRONT DINING. CHECK PLAN -MIGHT DOUBLE JOIST UNDER KITCHEN ISLAND. CHECK PLAN PLUMBING: -PROTECT CSST GAS LINE AT ENTRY INTO FIREPLACE -PROTECT PLUMBING IN MASTER BATH ELECTRICAL: -REAR LIVING RM WALL RECEPTACLE SPACING NOT COMPLIANT; SAME FOR THE MIDDLE BED ROOM ABOVE -PROTECT WIRING ABOVE KITCHEN RANGE MECHANICAL: -COMPLETE DUCTING OF BATH FAN AND HOOD TO OUTDOOR ****DO NOT INSULATE
All Rough Inspection - Residential Failed 5/11/2017 5/11/2017 05/11/2017
Misc
Corrective Action Required
05/09/2017
FRAMING: -PROVIDE FULL CITY APPROVED PLAN ON SITE **INSTALL DOUBLE LVL BEAM ABOVE GARAGE PER PLAN **HAVE ENGINEER OK THE LARGER I BEAM AT STAIR IN BASEMENT. PLAN CALLS FOR SMALLER BEAM WITH ADDITIONAL COLUMN SUPPORT **INSTALL STEEL COLUMNS AS CALLED FOR ON PLAN **THE REAR DINING RM WALLS ARE CS-PF WALLS PER PLAN. HAVE ENGINEER ADDRESS FIX **THE TRIPLE BEAM ABOVE FRONT BED NOT EXTENDING ALL THE WAY TO THE BEARING WALL. HAVE ENGINEER ADDRESS -NAIL ALL EXTERIOR SIDING PER CODE **NAIL THE SIDING TO SILL PLATE @ 6" OC -GARAGE PORTAL BRACE WALLS: COMPLETE INSTALL SHEATHING TO THE REST OF THE WALL; SEAMS MUST BE WITHIN 24" OF MID-WALL HEIGHT; NAIL SHEATHING 3" OC -PROVIDE ATTIC ACCESS TO ROOF SPACE ABOVE GARAGE **HAVE YOUR ELECTRICIAN PROTECT THE WIRING NEAR THE ATTIC ACCESS -COMPLETE GARAGE SOFFIT AND FIREBLOCK AS REQUIRED **UNBLOCK THE COLD AIR RETURN SPACE **PAN OFF THE RA SPACE FROM SOFFIT -ABOVE GARAGE, FIX THE OVERNOTCHED JOIST AT SHOWER TRAP BY HEADER OFF TO ADJACENT JOIST. **INSTALL ANOTHER HEADER JOIST TO REDUCE SUBFLOOR SHEATHING SPAN TO 24" OR LESS -AT GARAGE WALL&CEILING RETURN AIR SPACE, PROVIDE R-15 THERMAL ENVELOP AT WALL AND R-19 AT CEILING **FUR OUT TO ALLOW R-15 INSULATION AT WALL AND R-19 AT CEILING -NAIL DOUBLE HANGER NEAR SUN RM INTERIOR DOOR -COMPLETE INSTALLING SUN RM EXTERIOR DOOR; INSTALL SECURITY BLOCKING; FILL IN ANY EXCESSIVE GAP AT HINGES AND STRIKE PLATE SIDE PER SECURITY CODE -HAVE THE ENGINEER ADDRESS THE FULL SUPPORT FOR THE I BEAM THAT SPANS FROM EAST SIDE OF HOUSE TO CORNER OF DUCT CHASE **PLAN ALSO CALLS FOR STEEL COLUMN SUPPORT -ABOVE FRONT DINING AREA, INSTALL A BEAM UNDER POINT LOAD OF THE ROOF SUPPORT BEAM ABOVE FRONT BED. CHECK WITH THE ENGINEER **SEE THE FIRST DEFICIENCY -BRACE INTERIOR WALLS PER PLAN **MASTER BED WALL MECHANICAL: -COMPLETE DUCTING OF BATH FAN AND HOOD TO OUTDOOR ***OK TO INSULATE
Gas Service Inspection - Residential Passed 5/11/2017 5/11/2017 05/11/2017
Misc
Resolved
05/11/2017
-NO PRESSURE
Driveway Inspection Partial 5/16/2017 5/16/2017 05/16/2017
Sidewalk Inspection Partial 5/16/2017 5/16/2017 05/16/2017
PW-Install sidewalk
Corrective Action Required
05/16/2017
There is sidewalk on your property which must be installed. *4ft of the sidewalk was pumping so I told the contractor to dig it up. When he dug it up we noticed it was holding water so they put a board in front of it and will come back to compact the rock and re do that area later.
All Rough Inspection - Residential Failed 6/7/2017 6/7/2017 06/07/2017
Misc
Corrective Action Required
05/11/2017
-INSTALL STEEL COLUMNS AS CALLED FOR ON PLAN FOR THE STEEL BEAM SPANNING BETWEEN FOYER&DINING AND THE LIVING RM -COMPLETE GARAGE SOFFIT AND FIREBLOCK AS REQUIRED **PAN OFF THE RA SPACE FROM SOFFIT -AT GARAGE WALL&CEILING RETURN AIR SPACE, PROVIDE R-15 THERMAL ENVELOP AT WALL AND R-19 AT CEILING **PROVIDE SPACE TO ALLOW R-15 INSULATION AT WALL AND R-19 AT CEILING. PAN OFF RA SPACE FROM INSULATION -HAVE THE ENGINEER ADDRESS THE FULL SUPPORT FOR THE I BEAM THAT SPANS FROM EAST SIDE OF HOUSE TO CORNER OF DUCT CHASE **PLAN ALSO CALLS FOR STEEL COLUMN SUPPORT **CURRENT STUDS SUPPORT ONLY SUPPORT THE I BEAM ON THE SIDE, NOT AT THE MIDDLE OR FULL WIDTH ***OK TO INSULATE
All Rough Inspection - Residential Passed 6/15/2017 6/15/2017 06/15/2017
Misc
Resolved
06/15/2017
-INSTALL STEEL COLUMNS AS CALLED FOR ON PLAN FOR THE STEEL BEAM SPANNING BETWEEN FOYER&DINING AND THE LIVING RM -COMPLETE GARAGE SOFFIT AND FIREBLOCK AS REQUIRED **PAN OFF THE RA SPACE FROM SOFFIT -AT GARAGE WALL&CEILING RETURN AIR SPACE, PROVIDE R-15 THERMAL ENVELOP AT WALL AND R-19 AT CEILING **PROVIDE SPACE TO ALLOW R-15 INSULATION AT WALL AND R-19 AT CEILING. PAN OFF RA SPACE FROM INSULATION -HAVE THE ENGINEER ADDRESS THE FULL SUPPORT FOR THE I BEAM THAT SPANS FROM EAST SIDE OF HOUSE TO CORNER OF DUCT CHASE **PLAN ALSO CALLS FOR STEEL COLUMN SUPPORT **CURRENT STUDS SUPPORT ONLY SUPPORT THE I BEAM ON THE SIDE, NOT AT THE MIDDLE OR FULL WIDTH ***OK TO INSULATE
Driveway Inspection Passed 5/18/2017 10/09/2017
Sidewalk Inspection Partial 10/9/2017 10/9/2017 10/09/2017
PW-Install sidewalk
Corrective Action Required
05/16/2017
There is sidewalk on your property which must be installed. *4ft of the sidewalk was pumping so I told the contractor to dig it up. When he dug it up we noticed it was holding water so they put a board in front of it and will come back to compact the rock and re do that area later.
Sidewalk Inspection Passed 10/11/2017 at 11:25 AM 10/10/2017
PW-Install sidewalk
Corrective Action Required
10/09/2017
There is sidewalk on your property which must be installed. *4ft of the sidewalk was pumping so I told the contractor to dig it up. When he dug it up we noticed it was holding water so they put a board in front of it and will come back to compact the rock and re do that area later.
Occupancy Inspection - Codes Residential Failed 5/22/2018 5/22/2018 at 8:55 AM 05/22/2018
Misc
Corrective Action Required
05/22/2018
-INSTALL THE SEWER TRACER BOX AND WIRE AT FINAL GRADE -OBTAIN LAWN IRRIGATION PERMIT AND SUBMIT TO CITY THE BACKFLOW TEST REPORT -SEAL EXTERIOR: SEAL ABOVE METER AND AC DISCONNECT, LIGHTS, ANY PENETRATIONS, ETC -TAPE UNGROUNDED AC CONDUCTORS WITH PROPER COLOR -SUPPORT FRONT ENTRY GFCI RECEPTACLE YOKE -AT EACH REAR EXTERIOR DOOR, INSTALL 3" SCREWS TO FASTEN THE EMBEDDED METAL BRACES INTO STUDS -BASEMENT STAIR HANDRAIL SHALL EXTEND FROM TOP RISER TO BOTTOM STAIR RISER -COOKTOP: SECURE FLEXIBLE METAL RACEWAY WITHIN 12" OF BOTH THE J-BOX AND COOKTOP TERMINATION ENCLOSURE; INSTALL LISTED CONNECTOR AT CONNECTION TO COOKTOP J-BOX -INSTALL BREAKER LOCKS FOR OVEN, COOKTOP, AND HOOD > 300 VA -SECURE SE CABLE WITHIN 12" OF SERVICE PANEL -SECURELY FASTEN AND SUPPORT NM CABLE AT INTERVAL NO MORE THAN 4.5 FT -SECURE FURNACE RACEWAY PER CODE -NO PENDANT LIGHT SHALL BE ALLOWED INSIDE THE MASTER CLOSET (OR ANY CLOTHES CLOSET)
Occupancy Inspection - Codes Residential Temporary C of O 6/12/2018 6/12/2018 at 3:25 PM 06/12/2018
Misc
Corrective Action Required
05/22/2018
-COOKTOP: SECURE FLEXIBLE METAL RACEWAY WITHIN 12" OF BOTH THE J-BOX AND COOKTOP TERMINATION ENCLOSURE; INSTALL LISTED CONNECTOR AT FMC CONNECTION TO COOKTOP J-BOX -INSTALL BREAKER LOCKS FOR COOKTOP
Occupancy Inspection - Codes Residential Full C of O 6/13/2018 6/13/2018 at 9:05 AM 06/13/2018
Misc
Resolved
06/13/2018
-COOKTOP: SECURE FLEXIBLE METAL RACEWAY WITHIN 12" OF BOTH THE J-BOX AND COOKTOP TERMINATION ENCLOSURE; INSTALL LISTED CONNECTOR AT FMC CONNECTION TO COOKTOP J-BOX -INSTALL BREAKER LOCKS FOR COOKTOP
Documents & Images
Date Uploaded File Type Document Name
01/12/2017 Receipt Receipt for transaction: 2017-000109
01/12/2017 Letter Codes Building Permit
01/13/2017 Plot Plan DOC011317-005
01/20/2017 Letter Inspection Summary
02/08/2017 Letter Inspection Summary
02/15/2017 Letter Inspection Summary
02/17/2017 Letter Inspection Summary
02/17/2017 Letter Inspection Summary
04/10/2017 Letter Inspection Summary
05/09/2017 Letter Inspection Summary
05/11/2017 Letter Inspection Summary
06/07/2017 Letter Inspection Summary
06/15/2017 Letter Inspection Summary
06/20/2017 Engineer Report/Study DOC062017-004
05/22/2018 Letter Inspection Summary
06/12/2018 Letter Codes Temporary Certificate of Occupancy
06/13/2018 Letter Field Certificate of Occupancy
06/14/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home